Innovative techniques for placement of implantable cardioverter-defibrillator leads in patients with limited venous access to the heart

被引:82
作者
Cannon, BC [1 ]
Friedman, RA [1 ]
Fenrich, AL [1 ]
Fraser, CD [1 ]
McKenzie, ED [1 ]
Kertesz, NJ [1 ]
机构
[1] Texas Childrens Hosp, Baylor Coll Med, Div Pediat, Cardiol Sect, Houston, TX 77030 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2006年 / 29卷 / 02期
关键词
implantable cardioverter-defibrillator; pediatric cardiology;
D O I
10.1111/j.1540-8159.2006.00314.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Because of venous occlusion, intracardiac shunting, previous surgery, or small size placement of implantable cardioverter-defibrillator (ICD) leads may not be possible using traditional methods. The purpose of this study was to evaluate and describe innovative methods of placing ICD leads. Methods: The records of all patients undergoing ICD implantation at our institution were reviewed to identify patients with nontraditional lead placement. Indications for ICD, method of lead and coil placement, defibrillation thresholds, complications, and follow-up results were reviewed retrospectively. Results: Eight patients (aged 11 months to 29 years) were identified. Six patients with limited venous access to the heart (four extracardiac Fontan, one bidirectional Glenn, one 8 kg 11-month-old) underwent surgical placement of an ICD coil directly into the pericardial sac. A second bipolar lead was placed on the ventricle for sensing and pacing. Two patients with difficult venous access had a standard transvenous ICD lead inserted directly into the right atrium (transatrial approach) and then positioned into the ventricle. All patients had a defibrillation threshold of < 20 J, although one patient required placement of a second coil due to an elevated threshold. There have been no complications and two successful appropriate ICD discharges at follow-up (median 22 months, range 5-42 months). Conclusions: Many factors may prohibit transvenous ICD lead placement. Nontraditional surgical placement of subcutaneous ICD leads on the pericardium or the use of a transatrial approach can be effective techniques in these patients. These procedures can be performed at low risk to the patient with excellent defibrillation thresholds.
引用
收藏
页码:181 / 187
页数:7
相关论文
共 25 条
  • [1] Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics
    Alexander, ME
    Cecchin, F
    Walsh, EP
    Triedman, JK
    Bevilacqua, LM
    Berul, CI
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (01) : 72 - 76
  • [2] Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    Bardy, GH
    Lee, KL
    Mark, DB
    Poole, JE
    Packer, DL
    Boineau, R
    Domanski, M
    Troutman, C
    Anderson, J
    Johnson, G
    McNulty, SE
    Clapp-Channing, N
    Davidson-Ray, LD
    Fraulo, ES
    Fishbein, DP
    Luceri, RM
    Ip, JH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) : 225 - 237
  • [3] Minimally invasive Cardioverter defibrillator implantation for children: An animal model and pediatric case report
    Berul, CI
    Triedman, JK
    Forbess, J
    Bevilacqua, LM
    Alexander, ME
    Dahlby, D
    Gilkerson, JO
    Walsh, EP
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (12): : 1789 - 1794
  • [4] A randomized study of the prevention of sudden death in patients with coronary artery disease
    Buxton, AE
    Lee, KL
    Fisher, JD
    Josephson, ME
    Prystowsky, EN
    Hafley, G
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) : 1882 - 1890
  • [5] Symptomatic pericardial disease associated with patch electrodes of the automatic implantable cardioverter defibrillator: An underestimated complication?
    Chevalier, P
    Moncada, E
    Canu, G
    Claudel, JP
    Bellon, C
    Kirkorian, G
    Touboul, P
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (12): : 2150 - 2152
  • [6] Cardiac strangulation, a rare complication of epicardial pacemaker leads during growth
    Eyskens, B
    Mertens, L
    Moerman, P
    Ector, H
    Daenen, W
    Gewillig, M
    [J]. HEART, 1997, 77 (03) : 288 - 289
  • [7] Incidence of lead system malfunction detected during implantable defibrillator generator replacement
    Goyal, R
    Harvey, M
    Horwood, L
    Bogun, F
    Castellani, M
    Chan, KK
    Daoud, E
    Niebauer, M
    Man, KC
    Morady, F
    Strickberger, SA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (08): : 1143 - 1146
  • [8] AT WORK - A NOVEL-APPROACH TO ATRIAL ENDOCARDIAL PACING
    HAYES, DL
    VLIETSTRA, RE
    PUGA, FJ
    SHUB, C
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (01): : 125 - 130
  • [9] TRANSATRIAL LEAD PLACEMENT FOR ENDOCARDIAL PACING IN CHILDREN
    HOYER, MH
    BEERMAN, LB
    ETTEDGUI, JA
    PARK, SC
    DELNIDO, PJ
    SIEWERS, RD
    [J]. ANNALS OF THORACIC SURGERY, 1994, 58 (01) : 97 - 101
  • [10] Long-term experience with subcutaneous ICD leads:: A comparison among three different types of subcutaneous leads
    Kettering, K
    Mewis, C
    Dörnberger, V
    Vonthein, R
    Bosch, RF
    Seipel, L
    Kühlkamp, V
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (10): : 1355 - 1361