Airway Occlusion Pressure As an Estimate of Respiratory Drive and Inspiratory Effort during Assisted Ventilation

被引:116
作者
Telias, Irene [1 ,3 ,4 ]
Junhasavasdikul, Detajin [1 ,3 ,5 ]
Rittayamai, Nuttapol [1 ,3 ,6 ]
Piquilloud, Lise [7 ,8 ]
Chen, Lu [1 ,3 ]
Ferguson, Niall D. [1 ,2 ,4 ,9 ]
Goligher, Ewan C. [1 ,4 ,9 ]
Brochard, Laurent [1 ,3 ]
机构
[1] Univ Toronto, Interdept Div Crit Care Med, Toronto, ON, Canada
[2] Univ Toronto, Inst Hlth Policy Management & Evaluat, Toronto, ON, Canada
[3] St Michaels Hosp, Keenan Res Ctr, Li Ka Shing Knowledge Inst, Toronto, ON, Canada
[4] Univ Hlth Network & Sinai Hlth Syst, Dept Med, Div Respirol, Toronto, ON, Canada
[5] Mahidol Univ, Dept Med, Fac Med, Ramathibodi Hosp, Bangkok, Thailand
[6] Mahidol Univ, Fac Med, Dept Med, Div Resp Dis & TB,Siriraj Hosp, Bangkok, Thailand
[7] Univ Hosp Lausanne, Adult Intens Care & Burn Unit, Lausanne, Switzerland
[8] Univ Lausanne, Lausanne, Switzerland
[9] Toronto Gen Hosp, Res Inst, Toronto, ON, Canada
关键词
artificial respiration; airway occlusion pressure; P0.1; myotrauma; diaphragm; MECHANICAL VENTILATION; SUPPORT VENTILATION; DIAPHRAGM INJURY; T-PIECE; TRIAL; ASYNCHRONY; DYSPNEA; IMPACT; MUSCLE; TIME;
D O I
10.1164/rccm.201907-1425OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale: Monitoring and controlling respiratory drive and effort may help to minimize lung and diaphragm injury. Airway occlusion pressure (P0.1) is a noninvasive measure of respiratory drive. Objectives: To determine 1) the validity of "ventilator" P0.1 (P0.1vent) displayed on the screen as a measure of drive, 2) the ability of P0.1 to detect potentially injurious levels of effort, and 3) how P0.1vent displayed by different ventilators compares to a "reference" P0.1 (P0.1ref) measured from airway pressure recording during an occlusion. Methods: Analysis of three studies in patients, one in healthy subjects, under assisted ventilation, and a bench study with six ventilators. P0.1 vent was validated against measures of drive (electrical activity of the diaphragm and muscular pressure over time) and P0.1ref Performance of P0.1ref and P0.1vent to detect predefined potentially injurious effort was tested using derivation and validation datasets using esophageal pressure-time product as the reference standard. Measurements and Main Results: P0.1vent correlated well with measures of drive and with the esophageal pressure-time product (within-subjects R-2 = 0.8). P0.1 ref >3.5 cm H2O was 80% sensitive and 77% specific for detecting high effort (>= 200 cm H2O center dot s.min(-1)); P0.1 ref <= 1.0 cm H2O was 100% sensitive and 92% specific for low effort (<= 50 cm H2O center dot s.min(-1)). The area under the receiver operating characteristics curve for P0.1 vent to detect potentially high and low effort were 0.81 and 0.92, respectively. Bench experiments showed a low mean bias for P0.1 vent compared with P0.1 ref for most ventilators but precision varied; in patients, precision was lower. Ventilators estimating P0.1 vent without occlusions could underestimate P0.1 ref. Conclusions: P0.1 is a reliable bedside tool to assess respiratory drive and detect potentially injurious inspiratory effort.
引用
收藏
页码:1086 / 1098
页数:13
相关论文
共 50 条
[31]   Reliability of Airway Occlusion Pressure as an Index of Respiratory Motor Output [J].
Kera, Takeshi ;
Aihara, Akiko ;
Inomata, Takashi .
RESPIRATORY CARE, 2013, 58 (05) :845-849
[32]   Respiratory drive with pressure support ventilation. [J].
Lofaso, F .
REVUE DES MALADIES RESPIRATOIRES, 1999, 16 (05) :781-787
[33]   Flow Index accurately identifies breaths with low or high inspiratory effort during pressure support ventilation [J].
Filippo Albani ;
Federica Fusina ;
Gianni Ciabatti ;
Luigi Pisani ;
Valeria Lippolis ;
Maria Elena Franceschetti ;
Alessia Giovannini ;
Rossella di Mussi ;
Francesco Murgolo ;
Antonio Rosano ;
Salvatore Grasso ;
Giuseppe Natalini .
Critical Care, 25
[34]   Flow Index accurately identifies breaths with low or high inspiratory effort during pressure support ventilation [J].
Albani, Filippo ;
Fusina, Federica ;
Ciabatti, Gianni ;
Pisani, Luigi ;
Lippolis, Valeria ;
Franceschetti, Maria Elena ;
Giovannini, Alessia ;
di Mussi, Rossella ;
Murgolo, Francesco ;
Rosano, Antonio ;
Grasso, Salvatore ;
Natalini, Giuseppe .
CRITICAL CARE, 2021, 25 (01)
[35]   The Impact of Spontaneous Ventilation on Distribution of Lung Aeration in Patients with Acute Respiratory Distress Syndrome: Airway Pressure Release Ventilation Versus Pressure Support Ventilation [J].
Yoshida, Takeshi ;
Rinka, Hiroshi ;
Kaji, Arito ;
Yoshimoto, Akira ;
Arimoto, Hideki ;
Miyaichi, Toshinori ;
Kan, Masanori .
ANESTHESIA AND ANALGESIA, 2009, 109 (06) :1892-1900
[36]   Closed-loop control of respiratory drive using pressure-support ventilation - Target drive ventilation [J].
Spahija, J ;
Beck, J ;
de Marchie, M ;
Comtois, A ;
Sinderby, C .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 171 (09) :1009-1014
[37]   Deep inspiratory breath hold assisted by continuous positive airway pressure ventilation for lung stereotactic body radiotherapy [J].
Appel, S. ;
Lawrence, Y. R. ;
Bar, J. ;
Jacobson, G. ;
Marom, E. M. ;
Katzman, T. ;
Ben-Ayun, M. ;
Dubinski, S. ;
Haisraely, O. ;
Weizman, N. ;
Davidson, T. ;
Weiss, I. ;
Mansano, A. ;
Goldstein, J. D. ;
Symon, Z. .
CANCER RADIOTHERAPIE, 2023, 27 (01) :23-30
[38]   A novel non-invasive method to detect excessively high respiratory effort and dynamic transpulmonary driving pressure during mechanical ventilation [J].
Bertoni, Michele ;
Telias, Irene ;
Urner, Martin ;
Long, Michael ;
Del Sorbo, Lorenzo ;
Fan, Eddy ;
Sinderby, Christer ;
Beck, Jennifer ;
Liu, Ling ;
Qiu, Haibo ;
Wong, Jenna ;
Slutsky, Arthur S. ;
Ferguson, Niall D. ;
Brochard, Laurent J. ;
Goligher, Ewan C. .
CRITICAL CARE, 2019, 23 (01)
[39]   Flow and airway pressure analysis for detecting ineffective effort during mechanical ventilation in neuromuscular patients [J].
Ciorba, Cristina ;
Gonzalez-Bermejo, Jesus ;
Salva, Maria-Antonia Quera ;
Annane, Djillali ;
Orlikowski, David ;
Lofaso, Frederic ;
Prigent, Helene .
CHRONIC RESPIRATORY DISEASE, 2018, 16
[40]   Involvement of Respiratory Muscles During the Timed Inspiratory Effort Index Measurement With Surface Electromyography [J].
Leite de Souza Costa, Helson Lino ;
de Souza, Leonardo Cordeiro ;
da Silva Neto, Arthur Evangelista ;
da Silva Guimaraes, Bruno Leonardo ;
de Azeredo, Leandro Miranda ;
Parada Godoy, Marcos David ;
Lugon, Jocemir Ronaldo .
RESPIRATORY CARE, 2020, 65 (12) :1857-1863