Airway Occlusion Pressure As an Estimate of Respiratory Drive and Inspiratory Effort during Assisted Ventilation

被引:116
作者
Telias, Irene [1 ,3 ,4 ]
Junhasavasdikul, Detajin [1 ,3 ,5 ]
Rittayamai, Nuttapol [1 ,3 ,6 ]
Piquilloud, Lise [7 ,8 ]
Chen, Lu [1 ,3 ]
Ferguson, Niall D. [1 ,2 ,4 ,9 ]
Goligher, Ewan C. [1 ,4 ,9 ]
Brochard, Laurent [1 ,3 ]
机构
[1] Univ Toronto, Interdept Div Crit Care Med, Toronto, ON, Canada
[2] Univ Toronto, Inst Hlth Policy Management & Evaluat, Toronto, ON, Canada
[3] St Michaels Hosp, Keenan Res Ctr, Li Ka Shing Knowledge Inst, Toronto, ON, Canada
[4] Univ Hlth Network & Sinai Hlth Syst, Dept Med, Div Respirol, Toronto, ON, Canada
[5] Mahidol Univ, Dept Med, Fac Med, Ramathibodi Hosp, Bangkok, Thailand
[6] Mahidol Univ, Fac Med, Dept Med, Div Resp Dis & TB,Siriraj Hosp, Bangkok, Thailand
[7] Univ Hosp Lausanne, Adult Intens Care & Burn Unit, Lausanne, Switzerland
[8] Univ Lausanne, Lausanne, Switzerland
[9] Toronto Gen Hosp, Res Inst, Toronto, ON, Canada
关键词
artificial respiration; airway occlusion pressure; P0.1; myotrauma; diaphragm; MECHANICAL VENTILATION; SUPPORT VENTILATION; DIAPHRAGM INJURY; T-PIECE; TRIAL; ASYNCHRONY; DYSPNEA; IMPACT; MUSCLE; TIME;
D O I
10.1164/rccm.201907-1425OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale: Monitoring and controlling respiratory drive and effort may help to minimize lung and diaphragm injury. Airway occlusion pressure (P0.1) is a noninvasive measure of respiratory drive. Objectives: To determine 1) the validity of "ventilator" P0.1 (P0.1vent) displayed on the screen as a measure of drive, 2) the ability of P0.1 to detect potentially injurious levels of effort, and 3) how P0.1vent displayed by different ventilators compares to a "reference" P0.1 (P0.1ref) measured from airway pressure recording during an occlusion. Methods: Analysis of three studies in patients, one in healthy subjects, under assisted ventilation, and a bench study with six ventilators. P0.1 vent was validated against measures of drive (electrical activity of the diaphragm and muscular pressure over time) and P0.1ref Performance of P0.1ref and P0.1vent to detect predefined potentially injurious effort was tested using derivation and validation datasets using esophageal pressure-time product as the reference standard. Measurements and Main Results: P0.1vent correlated well with measures of drive and with the esophageal pressure-time product (within-subjects R-2 = 0.8). P0.1 ref >3.5 cm H2O was 80% sensitive and 77% specific for detecting high effort (>= 200 cm H2O center dot s.min(-1)); P0.1 ref <= 1.0 cm H2O was 100% sensitive and 92% specific for low effort (<= 50 cm H2O center dot s.min(-1)). The area under the receiver operating characteristics curve for P0.1 vent to detect potentially high and low effort were 0.81 and 0.92, respectively. Bench experiments showed a low mean bias for P0.1 vent compared with P0.1 ref for most ventilators but precision varied; in patients, precision was lower. Ventilators estimating P0.1 vent without occlusions could underestimate P0.1 ref. Conclusions: P0.1 is a reliable bedside tool to assess respiratory drive and detect potentially injurious inspiratory effort.
引用
收藏
页码:1086 / 1098
页数:13
相关论文
共 50 条
  • [1] Airway Occlusion Pressure and P0.1 to Estimate Inspiratory Effort and Respiratory Drive in Ventilated Children
    Rudolph, Michelle W.
    Sietses, Maaike
    Koopman, Alette A.
    Blokpoel, Robert G. T.
    Kneyber, Martin C. J.
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2025, 26 (04) : e498 - e506
  • [2] Oesophageal pressure and respiratory muscle ultrasonographic measurements indicate inspiratory effort during pressure support ventilation
    Umbrello, Michele
    Formenti, Paolo
    Lusardi, Andrea C.
    Guanziroli, Mariateresa
    Caccioppola, Alessio
    Coppola, Silvia
    Chiumello, Davide
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2020, 125 (01) : E148 - E157
  • [3] Techniques to monitor respiratory drive and inspiratory effort
    Telias, Irene
    Spadaro, Savino
    [J]. CURRENT OPINION IN CRITICAL CARE, 2020, 26 (01) : 3 - 10
  • [4] Validation of the flow index to detect low inspiratory effort during pressure support ventilation
    Miao, Ming-Yue
    Chen, Wei
    Zhou, Yi-Min
    Gao, Ran
    Song, De-Jing
    Wang, Shu-Peng
    Yang, Yan-Lin
    Zhang, Linlin
    Zhou, Jian-Xin
    [J]. ANNALS OF INTENSIVE CARE, 2022, 12 (01)
  • [5] Effect of inspiratory synchronization during pressure-controlled ventilation on lung distension and inspiratory effort
    Rittayamai, Nuttapol
    Beloncle, Francois
    Goligher, Ewan C.
    Chen, Lu
    Mancebo, Jordi
    Richard, Jean-Christophe M.
    Brochard, Laurent
    [J]. ANNALS OF INTENSIVE CARE, 2017, 7
  • [6] Validation of Airway Occlusion Pressure as a Method of Assessing Breathing Effort During Noninvasive Ventilation
    Gogniat, Emiliano
    Steinberg, Emilio
    Tiribelli, Norberto
    Setten, Mariano
    Gutierrez, Facundo J.
    Plotnikow, Gustavo A.
    [J]. RESPIRATORY CARE, 2025,
  • [7] Timing of inspiratory muscle activity detected from airway pressure and flow during pressure support ventilation: the waveform method
    Mojoli, Francesco
    Pozzi, Marco
    Orlando, Anita
    Bianchi, Isabella M.
    Arisi, Eric
    Iotti, Giorgio A.
    Braschi, Antonio
    Brochard, Laurent
    [J]. CRITICAL CARE, 2022, 26 (01)
  • [8] The airway occlusion pressure (P0.1) to monitor respiratory drive during mechanical ventilation: increasing awareness of a not-so-new problem
    Irene Telias
    Felipe Damiani
    Laurent Brochard
    [J]. Intensive Care Medicine, 2018, 44 : 1532 - 1535
  • [9] Airway pressure morphology and respiratory muscle activity during end-inspiratory occlusions in pressure support ventilation
    Soundoulounaki, Stella
    Akoumianaki, Evangelia
    Kondili, Eumorfia
    Pediaditis, Emmanouil
    Prinianakis, Georgios
    Vaporidi, Katerina
    Georgopoulos, Dimitris
    [J]. CRITICAL CARE, 2020, 24 (01):
  • [10] Simulation of Late Inspiratory Rise in Airway Pressure During Pressure Support Ventilation
    Yu, Chun-Hsiang
    Su, Po-Lan
    Lin, Wei-Chieh
    Lin, Sheng-Hsiang
    Chen, Chang-Wen
    [J]. RESPIRATORY CARE, 2015, 60 (02) : 201 - 209