Airway Occlusion Pressure As an Estimate of Respiratory Drive and Inspiratory Effort during Assisted Ventilation

被引:115
|
作者
Telias, Irene [1 ,3 ,4 ]
Junhasavasdikul, Detajin [1 ,3 ,5 ]
Rittayamai, Nuttapol [1 ,3 ,6 ]
Piquilloud, Lise [7 ,8 ]
Chen, Lu [1 ,3 ]
Ferguson, Niall D. [1 ,2 ,4 ,9 ]
Goligher, Ewan C. [1 ,4 ,9 ]
Brochard, Laurent [1 ,3 ]
机构
[1] Univ Toronto, Interdept Div Crit Care Med, Toronto, ON, Canada
[2] Univ Toronto, Inst Hlth Policy Management & Evaluat, Toronto, ON, Canada
[3] St Michaels Hosp, Keenan Res Ctr, Li Ka Shing Knowledge Inst, Toronto, ON, Canada
[4] Univ Hlth Network & Sinai Hlth Syst, Dept Med, Div Respirol, Toronto, ON, Canada
[5] Mahidol Univ, Dept Med, Fac Med, Ramathibodi Hosp, Bangkok, Thailand
[6] Mahidol Univ, Fac Med, Dept Med, Div Resp Dis & TB,Siriraj Hosp, Bangkok, Thailand
[7] Univ Hosp Lausanne, Adult Intens Care & Burn Unit, Lausanne, Switzerland
[8] Univ Lausanne, Lausanne, Switzerland
[9] Toronto Gen Hosp, Res Inst, Toronto, ON, Canada
关键词
artificial respiration; airway occlusion pressure; P0.1; myotrauma; diaphragm; MECHANICAL VENTILATION; SUPPORT VENTILATION; DIAPHRAGM INJURY; T-PIECE; TRIAL; ASYNCHRONY; DYSPNEA; IMPACT; MUSCLE; TIME;
D O I
10.1164/rccm.201907-1425OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale: Monitoring and controlling respiratory drive and effort may help to minimize lung and diaphragm injury. Airway occlusion pressure (P0.1) is a noninvasive measure of respiratory drive. Objectives: To determine 1) the validity of "ventilator" P0.1 (P0.1vent) displayed on the screen as a measure of drive, 2) the ability of P0.1 to detect potentially injurious levels of effort, and 3) how P0.1vent displayed by different ventilators compares to a "reference" P0.1 (P0.1ref) measured from airway pressure recording during an occlusion. Methods: Analysis of three studies in patients, one in healthy subjects, under assisted ventilation, and a bench study with six ventilators. P0.1 vent was validated against measures of drive (electrical activity of the diaphragm and muscular pressure over time) and P0.1ref Performance of P0.1ref and P0.1vent to detect predefined potentially injurious effort was tested using derivation and validation datasets using esophageal pressure-time product as the reference standard. Measurements and Main Results: P0.1vent correlated well with measures of drive and with the esophageal pressure-time product (within-subjects R-2 = 0.8). P0.1 ref >3.5 cm H2O was 80% sensitive and 77% specific for detecting high effort (>= 200 cm H2O center dot s.min(-1)); P0.1 ref <= 1.0 cm H2O was 100% sensitive and 92% specific for low effort (<= 50 cm H2O center dot s.min(-1)). The area under the receiver operating characteristics curve for P0.1 vent to detect potentially high and low effort were 0.81 and 0.92, respectively. Bench experiments showed a low mean bias for P0.1 vent compared with P0.1 ref for most ventilators but precision varied; in patients, precision was lower. Ventilators estimating P0.1 vent without occlusions could underestimate P0.1 ref. Conclusions: P0.1 is a reliable bedside tool to assess respiratory drive and detect potentially injurious inspiratory effort.
引用
收藏
页码:1086 / 1098
页数:13
相关论文
共 50 条
  • [1] Airway Occlusion Pressure and P0.1 to Estimate Inspiratory Effort and Respiratory Drive in Ventilated Children
    Rudolph, Michelle W.
    Sietses, Maaike
    Koopman, Alette A.
    Blokpoel, Robert G. T.
    Kneyber, Martin C. J.
    PEDIATRIC CRITICAL CARE MEDICINE, 2025, 26 (04) : e498 - e506
  • [2] Assisted Ventilation: Is Shutter Pressure an Estimate of the Respiratory Drive?
    Simon, Annika
    PNEUMOLOGIE, 2020, 74 (07):
  • [3] AIRWAY OCCLUSION PRESSURE DURING ASSISTED VENTILATION
    CATHERINE, SH
    SASSOON, MD
    HICKS, D
    TE, TT
    MAHUTTE, CK
    LIGHT, RW
    CHEST, 1986, 89 (06) : S524 - S524
  • [4] INSPIRATORY EFFORT AND OCCLUSION PRESSURE IN TRIGGERED MECHANICAL VENTILATION
    FERNANDEZ, R
    BENITO, S
    SANCHIS, J
    MILICEMILI, J
    NET, A
    INTENSIVE CARE MEDICINE, 1988, 14 (06) : 650 - 653
  • [5] RESPIRATORY RESPONSE AND INSPIRATORY EFFORT DURING PRESSURE SUPPORT VENTILATION IN COPD PATIENTS
    NAVA, S
    BRUSCHI, C
    RUBINI, F
    PALO, A
    IOTTI, G
    BRASCHI, A
    INTENSIVE CARE MEDICINE, 1995, 21 (11) : 871 - 879
  • [6] RESPIRATORY CENTER OUTPUT IN INFANTS AS INDICATED BY INSPIRATORY PRESSURE DURING AIRWAY OCCLUSION
    FRANTZ, ID
    TAEUSCH, W
    WYSZOGRO.I
    WHITELAW, W
    MILICEMI.J
    AVERY, ME
    PEDIATRIC RESEARCH, 1974, 8 (04) : 467 - 467
  • [7] Oesophageal pressure and respiratory muscle ultrasonographic measurements indicate inspiratory effort during pressure support ventilation
    Umbrello, Michele
    Formenti, Paolo
    Lusardi, Andrea C.
    Guanziroli, Mariateresa
    Caccioppola, Alessio
    Coppola, Silvia
    Chiumello, Davide
    BRITISH JOURNAL OF ANAESTHESIA, 2020, 125 (01) : E148 - E157
  • [8] Validation of Airway Occlusion Pressure as a Method of Assessing Breathing Effort During Noninvasive Ventilation
    Gogniat, Emiliano
    Steinberg, Emilio
    Tiribelli, Norberto
    Setten, Mariano
    Gutierrez, Facundo J.
    Plotnikow, Gustavo A.
    RESPIRATORY CARE, 2025,
  • [9] Techniques to monitor respiratory drive and inspiratory effort
    Telias, Irene
    Spadaro, Savino
    CURRENT OPINION IN CRITICAL CARE, 2020, 26 (01) : 3 - 10
  • [10] Airway pressure morphology and respiratory muscle activity during end-inspiratory occlusions in pressure support ventilation
    Stella Soundoulounaki
    Evangelia Akoumianaki
    Eumorfia Kondili
    Emmanouil Pediaditis
    Georgios Prinianakis
    Katerina Vaporidi
    Dimitris Georgopoulos
    Critical Care, 24