High-Sensitive Fiber-Optic Refractometer Based on a Core-Diameter-Mismatch Mach-Zehnder Interferometer

被引:81
|
作者
Rong, Qiangzhou [1 ]
Qiao, Xueguang [1 ]
Wang, Ruohui [1 ]
Sun, Hao [1 ]
Hu, Manli [1 ]
Feng, Zhongyao [1 ]
机构
[1] NW Univ Xian, Dept Phys, Xian 710069, Peoples R China
基金
中国国家自然科学基金;
关键词
Fiber optics; fiber optics sensors; REFRACTIVE-INDEX SENSOR; MODAL INTERFEROMETER;
D O I
10.1109/JSEN.2012.2194700
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An in-fiber Mach-Zehnder interferometer (MZI) for high-sensitive refractive index (RI) measurement is proposed and experimentally demonstrated. The sensing head is formed by a single-mode fiber (SMF) sandwiched between two short sections of thin-core fibers (TCFs), i.e., TCF-SMF-TCF MZI configuration with a length of 9 mm. A well-defined interference pattern is obtained as the result of fiber-core mismatch and core-cladding modes interference. The selected interference dip is extremely sensitive to ambient RI, providing a stable RI response with sensitivity up to 159 nm/RIU for water-based solutions close to the RI of 1.33, making it a good candidate for bio-chemical measurements.
引用
收藏
页码:2501 / 2505
页数:5
相关论文
共 50 条
  • [31] Refractometer based on fiber Mach-Zehnder interferometer composed of two micro bending cores
    Ma, Yiwei
    Yi, Yang
    Li, Xiaoyang
    Su, Chunbo
    Zhang, Min
    Geng, Tao
    Sun, Weimin
    Yuan, Libo
    OPTICS EXPRESS, 2021, 29 (20) : 31443 - 31454
  • [32] Compact vector fiber-optic displacement sensor using an asymmetric Mach-Zehnder interferometer
    Yin, Xunli
    Zhou, Ruixiang
    OPTICS COMMUNICATIONS, 2017, 400 : 74 - 78
  • [33] Use of a fiber-optic Mach-Zehnder interferometer for creating a deformometer with extended gage length
    Kamenev, O. T.
    Kul'chin, Yu N.
    Petrov, Yu S.
    Khizhnyak, R. V.
    TECHNICAL PHYSICS LETTERS, 2014, 40 (02) : 119 - 122
  • [35] Remote upconversion in microwave fiber-optic links employing an unbalanced Mach-Zehnder interferometer
    Maury, G
    Hilt, A
    Cabon, B
    Girod, V
    Degoud, L
    TERAHERTZ AND GIGAHERTZ PHOTONICS, 1999, 3795 : 468 - 476
  • [36] MULTIMODE FIBER-OPTIC MACH-ZEHNDER INTERFEROMETER AND ITS USE IN TEMPERATURE-MEASUREMENT
    OKAMOTO, T
    YAMAGUCHI, I
    APPLIED OPTICS, 1988, 27 (15): : 3085 - 3087
  • [37] Fiber-optic In-line Mach-Zehnder Modal Interferometer for Breathing Monitoring Application
    Wang, Ketian
    Xu, Wei
    Zhang, Na
    Li, Kunpu
    Yu, Cheungchuem
    Yu, Changyuan
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [38] Use of a fiber-optic Mach-Zehnder interferometer for creating a deformometer with extended gage length
    O. T. Kamenev
    Yu. N. Kul’chin
    Yu. S. Petrov
    R. V. Khizhnyak
    Technical Physics Letters, 2014, 40 : 119 - 122
  • [39] Optical fiber core diameter mismatched in-fiber Mach-Zehnder interferometer for strain sensing
    Zhao Na
    Fu Haiwei
    Qiao Xueguang
    Shao Min
    Li Huidong
    Liu Qinpeng
    Gao Hong
    Yan Xu
    Zhang Yunshan
    INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING (ICPOE 2014), 2015, 9449
  • [40] Tapered Fiber-Optic Mach-Zehnder Interferometer for Ultra-High Sensitivity Measurement of Refractive Index
    Ahsani, Vahid
    Ahmed, Farid
    Jun, Martin B. G.
    Bradley, Colin
    SENSORS, 2019, 19 (07)