Stability and Marginal Bone Level Changes of SLActive Titanium-Zirconium Implants Placed with Flapless Surgery: A Prospective Pilot Study

被引:15
作者
Altinci, Pinar [1 ]
Can, Gulsen [1 ]
Gunes, Onur [2 ]
Ozturk, Caner [1 ]
Eren, Hakan [3 ]
机构
[1] Ankara Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
[2] Ankara Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Ankara, Turkey
[3] Ankara Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Ankara, Turkey
关键词
flapless surgery; immediate loading; marginal bone level; resonance frequency analysis; titanium-zirconium implant; IMMEDIATELY LOADED IMPLANTS; NARROW-DIAMETER IMPLANTS; DENTAL IMPLANT; FOLLOW-UP; EDENTULOUS RIDGES; SUCCESS; ALLOY;
D O I
10.1111/cid.12392
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundImmediately-loaded, narrow-diameter implants can be a less invasive alternative for the implant-supported fixed rehabilitation of narrow, posterior crests. PurposeTo determine the stability and marginal bone level (MBL) changes of narrow-diameter, titanium-zirconium (TiZr) implants placed with flapless surgery and loaded immediately in the posterior region. Materials and MethodsThirty-eight TiZr implants (3.3 mm diameter, 10 mm length, Roxolid, Straumann AG) were placed in the posterior crests of 14 patients with computer-guided flapless surgery as a support of 3-unit posterior bridges. Eighteen implants were loaded immediately, and 20 implants were loaded conventionally. The implant stability quotients were determined at the 1, 2, 4, and 8. weeks of healing before conventional loading, and at the 3, 6, and 12. months after loading by resonance frequency analysis. The MBL changes were measured by digital radiography. ResultsThe surgical protocols were accomplished without any biological complications. There was no significant difference in the stability changes of TiZr implants between the loading groups (p>.05). The MBL changes were -0.180.27 mm and -0.24 +/- 0.27 mm at the 12. month of immediate and conventional loading, respectively, which was not statistically significant (p>.05). ConclusionThe stability and MBL changes of TiZr implants supporting posterior 3-unit bridges were clinically acceptable at the first year of loading.
引用
收藏
页码:1193 / 1199
页数:7
相关论文
共 27 条
[21]  
Sennerby L, 1998, Compend Contin Educ Dent, V19, P493
[22]  
Sennerby L, 1998, COMPEND CONTIN ED DE, V19, P500
[23]  
Sennerby L, 1998, COMPEND CONTIN ED DE, V19, P502
[24]   Prognosis of immediately loaded implants and their restorations: a systematic literature review [J].
Strub, J. R. ;
Jurdzik, B. A. ;
Tuna, T. .
JOURNAL OF ORAL REHABILITATION, 2012, 39 (09) :704-717
[25]   Tissue Integration of a New Titanium-Zirconium Dental Implant: A Comparative Histologic and Radiographic Study in the Canine [J].
Thoma, Daniel S. ;
Jones, Archie A. ;
Dard, Michel ;
Grize, Leticia ;
Obrecht, Marcel ;
Cochran, David L. .
JOURNAL OF PERIODONTOLOGY, 2011, 82 (10) :1453-1461
[26]   Success and survival rates of narrow diameter implants made of titanium-zirconium alloy in the posterior region of the jaws - results from a 1-year follow-up [J].
Tolentino, L. ;
Sukekava, F. ;
Seabra, M. ;
Lima, L. A. ;
Garcez-Filho, J. ;
Araujo, M. G. .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) :137-141
[27]   An In Vitro Biomechanical Evaluation of a New Commercial Titanium-Zirconium Alloy Dental Implant: A Pilot Study [J].
Wu, Aaron Yu-Jen ;
Hsu, Jui-Ting ;
Huang, Heng-Li .
IMPLANT DENTISTRY, 2014, 23 (05) :534-538