Time-resolved infrared stimulated luminescence signals in feldspars: Analysis based on exponential and stretched exponential functions

被引:13
作者
Pagonis, V. [1 ]
Morthekai, P. [2 ]
Singhvi, A. K. [2 ]
Thomas, J. [3 ]
Balaram, V. [4 ]
Kitis, G. [5 ]
Chen, R. [6 ]
机构
[1] McDaniel Coll, Dept Phys, Westminster, MD 21157 USA
[2] Phys Res Lab, Geosci Div, Ahmadabad 380009, Gujarat, India
[3] Pondicherry Univ, Dept Earth Sci, Pondicherry 605014, India
[4] Natl Geophys Res Inst CSIR, Hyderabad 500007, Andhra Pradesh, India
[5] Aristotle Univ Thessaloniki, Nucl Phys Lab, Thessaloniki 54124, Greece
[6] Tel Aviv Univ, Raymond & Beverly Sackler Sch Phys & Astron, IL-69978 Tel Aviv, Israel
关键词
Infrared stimulated luminescence (IRSL); Time-resolved infrared stimulated luminescence (TR-IRSL); Feldspars; Tunneling; Stretched exponential functions; DECAY; ELECTRONS; OSL;
D O I
10.1016/j.jlumin.2012.04.020
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Time-resolved infrared-stimulated luminescence (TR-IRSL) signals from feldspar samples have been the subject of several recent experimental studies. These signals are of importance in the field of luminescence dating, since they exhibit smaller fading effects than the commonly employed continuous-wave infrared signals (CW-IRSL). This paper presents a semi-empirical analysis of TR-IRSL data from feldspar samples, by using a linear combination of exponential and stretched exponential (SE) functions. The best possible estimates of the five parameters in this semi-empirical approach are obtained using five popular commercially available software packages, and by employing a variety of global optimization techniques. The results from all types of software and from the different fitting algorithms were found to be in close agreement with each other, indicating that a global optimum solution has likely been reached during the fitting process. Four complete sets of TR-IRSL data on well-characterized natural feldspars were fitted by using such a linear combination of exponential and SE functions. The dependence of the extracted fitting parameters on the stimulation temperature is discussed within the context of a recently proposed model of luminescence processes in feldspar. Three of the four feldspar samples studied in this paper are K-rich, and these exhibited different behavior at higher stimulation temperatures, than the fourth sample which was a Na-rich feldspar. The new method of analysis proposed in this paper can help isolate mathematically the more thermally stable components, and hence could lead to better dating applications in these materials. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:2330 / 2340
页数:11
相关论文
共 25 条
  • [1] Adamiec G., 2004, GEOCHRONOMETRIA, V23, P9
  • [2] Finding model parameters: Genetic algorithms and the numerical modelling of quartz luminescence
    Adamiec, Grzegorz
    Bluszcz, Andrzej
    Bailey, Richard
    Garcia-Talavera, Marta
    [J]. RADIATION MEASUREMENTS, 2006, 41 (7-8) : 897 - 902
  • [3] Optically stimulated phosphorescence in quartz over the millisecond to second time scale: insights into the role of shallow traps in delaying luminescent recombination
    Ankjaergaard, C.
    Jain, M.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2010, 43 (25)
  • [4] Further investigations into pulsed optically stimulated luminescence from feldspars using blue and green light
    Ankjaergaard, C.
    Jain, M.
    Kalchgruber, R.
    Lapp, T.
    Klein, D.
    McKeever, S. W. S.
    Murray, A. S.
    Morthekai, P.
    [J]. RADIATION MEASUREMENTS, 2009, 44 (5-6) : 576 - 581
  • [5] FIGURE-OF-MERIT (FOM), AN IMPROVED CRITERION OVER NORMALIZED CHI-SQUARED TEST FOR ASSESSING GOODNESS-OF-FIT OF GAMMA-RAY SPECTRAL PEAKS
    BALIAN, HG
    EDDY, NW
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1977, 145 (02): : 389 - 395
  • [6] Mathematical functions for the analysis of luminescence decays with underlying distributions 1. Kohlrausch decay function (stretched exponential)
    Berberan-Santos, MN
    Bodunov, EN
    Valeur, B
    [J]. CHEMICAL PHYSICS, 2005, 315 (1-2) : 171 - 182
  • [7] BerberanSantos MN, 2008, SPRINGER SER FLUORES, V04, P1
  • [8] Application of differential evolution to fitting OSL decay curves
    Bluszcz, A.
    Adamiec, G.
    [J]. RADIATION MEASUREMENTS, 2006, 41 (7-8) : 886 - 891
  • [9] Review of optically stimulated luminescence (OSL) instrumental developments for retrospective dosimetry
    Botter-Jensen, L.
    Thomsen, K. J.
    Jain, M.
    [J]. RADIATION MEASUREMENTS, 2010, 45 (3-6) : 253 - 257
  • [10] Apparent stretched-exponential luminescence decay in crystalline solids
    Chen, R
    [J]. JOURNAL OF LUMINESCENCE, 2003, 102 : 510 - 518