Evaluation of enhanced corneal compensation in scanning laser polarimetry -: Comparison with variable corneal compensation on human eyes undergoing LASIK

被引:0
作者
Tóth, M [1 ]
Holló, G [1 ]
机构
[1] Semmelweis Univ, Dept Ophthalmol, H-1083 Budapest, Hungary
关键词
glaucoma; LASIK; retinal nerve fiber layer; scanning laser polarimetry;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the potential advantages of an enhanced corneal compensation algorithm (ECC) compared with variable corneal compensation (VCC), in scanning laser polarimetry. Methods: One eye of 15 healthy ametropic subjects was imaged immediately before and 7 days after uncomplicated LASIK surgery. Anterior segment bireffingence was assessed at each measurement session. For post-LASIK calculations, either actual post-LASIK corneal retardation (VCC and ECC groups), or the pre-LASIK corneal retardation (VCC* and ECC* groups) was used. Results: The typical scan score-value was higher for ECC both before and after LASIK (P < 0.01), and it was not influenced by LASIK in either compensation method. Botfi the axis and the magnitude of comeal birefringence altered after LASIK (P < 0.01). After LASIK, with VCC* all eyes showed uncompensated bireftingence, but with ECC* none did. LASIK had no effect on retinal nerve fiber layer measurements in VCC and ECC methods. In VCC* the LASIK-induced retinal nerve fiber layer thickness change was significant (P < 0.01) in the temporal, superior, and nasal quadrants. After LASIK, the number of significantly altered sectors along the TSNIT plot showed no difference when comparing VCC and ECC, VCC and ECC*, or ECC and ECC*. In contrast, significantly more sectors were altered in VCC* than in either VCC or FCC* (P < 0.001). Conclusions: The new ECC software is more effective than VCC in neutralization of atypical polarization pattern and the uncompensated corneal retardation.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 36 条
[31]   Comparison between fixed-angle and customised corneal-polarisation compensation methods in scanning laser polarimetric measurement of the retinal nerve fibre layer in glaucoma [J].
A Katsanos ;
P Kóthy ;
G Holló .
Eye, 2005, 19 :152-158
[32]   Discrimination between normal and early glaucomatous eyes with scanning laser polarimeter with fixed and variable corneal compensator settings [J].
Brusini, P ;
Salvetat, ML ;
Parisi, L ;
Zeppieri, M ;
Tosoni, C .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (04) :468-476
[33]   Accuracy of GDx variable corneal compensation polarization measurements in normal human eyes: effect of accommodation, cycloplegia, focus, pupil size, and eye selection on reproducibility [J].
Levy, N. S. ;
Schachar, I. H. .
EYE, 2007, 21 (03) :333-340
[34]   Accuracy of GDx variable corneal compensation polarization measurements in normal human eyes: effect of accommodation, cycloplegia, focus, pupil size, and eye selection on reproducibility [J].
N S Levy ;
I H Schachar .
Eye, 2007, 21 :333-340
[35]   The Impact of Retardance Pattern Variability on Nerve Fiber Layer Measurements over Time Using GDx with Variable and Enhanced Corneal Compensation [J].
Grewal, Dilraj S. ;
Sehi, Mitra ;
Cook, Richard J. ;
Greenfield, David S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) :4516-4524
[36]   Effect of cataract surgery and foldable intraocular lens implantation on retinal nerve fiber layer as measured by scanning laser polarimetry with variable corneal compensator [J].
Vetrugno, M ;
Trabucco, T ;
Sisto, D ;
Sborgia, C .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2004, 14 (02) :106-110