Battery Storage Systems as Grid-Balancing Measure in Low-Voltage Distribution Grids with Distributed Generation

被引:31
作者
Faessler, Bernhard [1 ,2 ,3 ]
Schuler, Michael [1 ]
Preissinger, Markus [2 ]
Kepplinger, Peter [1 ,2 ]
机构
[1] Vorarlberg Univ Appl Sci, Josef Ressel Ctr Appl Sci Comp Energy Finance & L, Hsch Str 1, A-6850 Dornbirn, Austria
[2] Vorarlberg Univ Appl Sci, Illwerke Vkw Endowed Professorship Energy Efficie, Hsch Str 1, A-6850 Dornbirn, Austria
[3] Univ Agder, Fac Sci & Engn, Jon Lilletuns Vei 9, N-4879 Grimstad, Norway
关键词
grid balancing; grid simulation; autonomously optimized battery storage; distributed generation; central and distributed energy storage; DEMAND-SIDE MANAGEMENT; ENERGY-STORAGE; ECONOMIC-ANALYSIS; RENEWABLE ENERGY; CONSUMPTION; INTEGRATION;
D O I
10.3390/en10122161
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the promoted integration of renewable sources, a further growth of strongly transient, distributed generation is expected. Thus, the existing electrical grid may reach its physical limits. To counteract this, and to fully exploit the viable potential of renewables, grid-balancing measures are crucial. In this work, battery storage systems are embedded in a grid simulation to evaluate their potential for grid balancing. The overall setup is based on a real, low-voltage distribution grid topology, real smart meter household load profiles, and real photovoltaics load data. An autonomous optimization routine, driven by a one-way communicated incentive, determines the prospective battery operation mode. Different battery positions and incentives are compared to evaluate their impact. The configurations incorporate a baseline simulation without storage, a single, central battery storage or multiple, distributed battery storages which together have the same power and capacity. The incentives address either market conditions, grid balancing, optimal photovoltaic utilization, load shifting, or self-consumption. Simulations show that grid-balancing incentives result in lowest peak-to-average power ratios, while maintaining negligible voltage changes in comparison to a reference case. Incentives reflecting market conditions for electricity generation, such as real-time pricing, negatively influence the power quality, especially with respect to the peak-to-average power ratio. A central, feed-in-tied storage performs better in terms of minimizing the voltage drop/rise and shows lower distribution losses, while distributed storages attached at nodes with electricity generation by photovoltaics achieve lower peak-to-average power ratios.
引用
收藏
页数:14
相关论文
共 54 条
[1]  
Ackermann T, 2002, IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS, P1357, DOI 10.1109/TDC.2002.1177677
[2]  
[Anonymous], DEMAND SIDE MANAGEME
[3]  
[Anonymous], WIRTSCHAFTSWOCHE
[4]  
[Anonymous], OPT TOOLB
[5]  
[Anonymous], ABW EN AG EXAA EN EX
[6]  
[Anonymous], ADSM AKTIVES DEMAND
[7]  
[Anonymous], 50160201102 EN DIN
[8]  
[Anonymous], B ELECT
[9]  
[Anonymous], ANAL SIMULATION DIST
[10]  
[Anonymous], TECHN DAT SONN EC