CSI-EPT: A Contrast Source Inversion Approach for Improved MRI-Based Electric Properties Tomography

被引:93
作者
Balidemaj, Edmond [1 ]
van den Berg, Cornelis A. T. [2 ]
Trinks, Johan [1 ]
van Lier, Astrid L. H. M. W.
Nederveen, Aart J. [1 ]
Stalpers, Lukas J. A. [1 ]
Crezee, Hans [1 ]
Remis, Rob F. [3 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Radiotherapy & Radiol Dept, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Utrecht, Univ Med Ctr, Dept Radiotherapy, NL-3508 GA Utrecht, Netherlands
[3] Delft Univ Technol, Fac Elect Engn Math & Comp Sci, Circuits & Syst Grp, NL-2828 CD Delft, Netherlands
关键词
B1; map; EPT; electric properties tomography; dielectric tissue mapping; MRI; contrast source inversion; conductivity; permittivity; SAR; DIELECTRIC-PROPERTIES; ABSORPTION RATE; CONDUCTIVITY; TRANSMIT; TISSUES; COIL;
D O I
10.1109/TMI.2015.2404944
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Electric properties tomography (EPT) is an imaging modality to reconstruct the electric conductivity and permittivity inside the human body based on maps acquired by a magnetic resonance imaging (MRI) system. Current implementations of EPT are based on the local Maxwell equations and assume piecewise constant media. The accuracy of the reconstructed maps may therefore be sensitive to noise and reconstruction errors occur near tissue boundaries. In this paper, we introduce a multiplicative regularized CSI-EPT method (contrast source inversion-electric properties tomography) where the electric tissue properties are retrieved in an iterative fashion based on a contrast source inversion approach. The method takes the integral representations for the electromagnetic field as a starting point and the tissue parameters are obtained by iteratively minimizing an objective function which measures the discrepancy between measured and modeled data and the discrepancy in satisfying a consistency equation known as the object equation. Furthermore, the objective function consists of a multiplicative Total Variation factor for noise suppression during the reconstruction process. Finally, the presented implementation is able to simultaneously include more than one B-1(+) data set acquired by complementary RF excitation settings. We have performed in vivo simulations using a female pelvis model to compute the B-1(+) fields. Three different RF excitation settings were used to acquire complementary B-1(+) fields for an improved overall reconstruction. Numerical results illustrate the improved reconstruction near tissue boundaries and the ability of CSI-EPT to reconstruct small tissue structures.
引用
收藏
页码:1788 / 1796
页数:9
相关论文
共 40 条
[1]   Three-dimensional nonlinear inversion in cross-well electrode logging [J].
Abubakar, A ;
van den Berg, PM .
RADIO SCIENCE, 1998, 33 (04) :989-1004
[2]   Imaging of biomedical data using a multiplicative regularized contrast source inversion method [J].
Abubakar, A ;
van den Berg, PM ;
Mallorqui, JJ .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2002, 50 (07) :1761-1771
[3]  
Balanis C. A., 2012, ADV ENG ELECTROMAGNE, P933
[4]  
Balidemaj E., 2013, 2013 International Conference on Electromagnetics in Advanced Applications (ICEAA), P668, DOI 10.1109/ICEAA.2013.6632328
[5]  
Balidemaj E., 2013, P 19 ANN M INT SOC M, P4178
[6]  
Balidemaj E, 2014, P 22 ANN M ISMRM MIL, P3252
[7]   Feasibility of Electric Property Tomography of Pelvic Tumors at 3T [J].
Balidemaj, Edmond ;
van Lier, Astrid L. H. M. W. ;
Crezee, Hans ;
Nederveen, Aart J. ;
Stalpers, Lukas J. A. ;
van den Berg, Cornelis A. T. .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (04) :1505-1513
[8]   Iterative separation of transmit and receive phase contributions and B 1 + -based estimation of the specific absorption rate for transmit arrays [J].
Buchenau, Stefanie ;
Haas, Martin ;
Splitthoff, Daniel Nicolas ;
Hennig, Juergen ;
Zaitsev, Maxim .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (05) :463-476
[9]  
Chong E. K. P., 2013, INTRO OPTIMIZATION, P187
[10]   The Virtual Family-development of surface-based anatomical models of two adults and two children for dosimetric simulations [J].
Christ, Andreas ;
Kainz, Wolfgang ;
Hahn, Eckhart G. ;
Honegger, Katharina ;
Zefferer, Marcel ;
Neufeld, Esra ;
Rascher, Wolfgang ;
Janka, Rolf ;
Bautz, Werner ;
Chen, Ji ;
Kiefer, Berthold ;
Schmitt, Peter ;
Hollenbach, Hans-Peter ;
Shen, Jianxiang ;
Oberle, Michael ;
Szczerba, Dominik ;
Kam, Anthony ;
Guag, Joshua W. ;
Kuster, Niels .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (02) :N23-N38