The use of diagnostic ultrasound in carpal tunnel syndrome

被引:179
作者
Wiesler, ER
Chloros, GD
Cartwright, MS
Smith, BP
Rushing, J
Walker, FO
机构
[1] Wake Forest Univ, Sch Med, Dept Orthopaed Surg, Winston Salem, NC 27157 USA
[2] Wake Forest Univ, Sch Med, Dept Orthopaed Surg, Winston Salem, NC 27157 USA
[3] Wake Forest Univ, Sch Med, Dept Neurol, Winston Salem, NC 27157 USA
[4] Wake Forest Univ, Sch Med, Dept Publ Hlth Sci, Winston Salem, NC 27157 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2006年 / 31A卷 / 05期
关键词
carpal tunnel syndrome; ultrasound;
D O I
10.1016/j.jhsa.2006.01.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Traditional evaluation of suspected carpal tunnel syndrome (CTS) involves a thorough history, physical examination, and nerve conduction velocity studies (NCS). Ultrasound is used widely in Europe and has gained acceptance in the United States in the diagnosis of various musculoskeletal disorders. The purpose of this study was to document the ultrasonographic measurement difference in median nerve size between patients with CTS and controls and to correlate these findings with NCS findings, thereby allowing us to test the validity of ultrasound as a diagnostic modality for CTS. Methods: Forty-four wrists in 26 CTS patients and 86 wrists in 43 asymptornatic volunteers were imaged using a real-time ultrasound scanner with a 12/5 MHz linear-array transducer. The cross-sectional area of the median nerve was measured at the level of the distal wrist crease in both CTS patients and controls. All CTS patients had NCS. The ultrasonographic median nerve area was compared for the 2 groups and correlation analysis between ultrasonographic nerve sizes and NCS findings was performed. Results: The average cross-sectional area of the median nerve at the distal wrist crease was 9 mm(2) in asymptornatic volunteers and 14 mm(2) in CTS patients. For the CTS patients the Pearson correlation coefficient between ultrasound nerve measurement and NCS values was 0.37, suggesting that higher values of ultrasound measurements are associated with abnormal NCS findings. Conclusions: Our results indicate that high-resolution ultrasound is informative in the evaluation of CTS and shows enlargement of the median nerve at the distal wrist crease in symptomatic patients. Therefore it is a reliable modality for imaging the wrist in patients with CTS. In addition ultrasound is well tolerated and safe.
引用
收藏
页码:726 / 732
页数:7
相关论文
共 50 条
  • [41] Diagnostic potential of ultrasound in carpal tunnel syndrome with different etiologies: correlation of sonographic median nerve measures with electrodiagnostic severity
    Elnady, Basant
    Rageh, Elsayed M.
    Ekhouly, Tohamy
    Fathy, Sabry M.
    Alshaar, Mohamed
    Fouda, El Saeed
    Attar, Mohammed
    Abdelaal, Ahmed M.
    El Tantawi, Ahmed
    Algethami, Mohammed M.
    Bong, David
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [42] The diagnostic accuracy of high-resolution ultrasound in screening for carpal tunnel syndrome and grading its severity is moderated by age
    Moschovos, Christos
    Tsivgoulis, Georgios
    Kyrozis, Andreas
    Ghika, Apostolia
    Karachalia, Persefoni
    Voumvourakis, Konstantinos
    Chroni, Elisabeth
    CLINICAL NEUROPHYSIOLOGY, 2019, 130 (03) : 321 - 330
  • [43] Diagnostic Accuracy of Integrating Ultrasound and Shear Wave Elastography in Assessing Carpal Tunnel Syndrome Severity: a Prospective Observational Study
    El-Maghraby, Ahmed Mohamed
    Almalki, Yassir Edrees
    Basha, Mohammad Abd Alkhalik
    Nada, Mohamad Gamal
    El Ahwany, Fatma
    Alduraibi, Sharifa Khalid
    Alshehri, Shaker Hassan S.
    Aldhilan, Asim S.
    Almushayti, Ziyad A.
    Alduraibi, Alaa K.
    Aboualkheir, Mervat
    Attia, Osama
    Amer, Mona M.
    Basha, Ahmed M. Abdelkhalik
    Eladi, Ibrahim M.
    ORTHOPEDIC RESEARCH AND REVIEWS, 2024, 16 : 111 - 123
  • [44] Use of Multiple Ultrasonographic Parameters in Confirmation of Carpal Tunnel Syndrome
    Azman, Drazen
    Hrabac, Pero
    Demarin, Vida
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (04) : 879 - 889
  • [45] Factors influencing the diagnostic process of carpal tunnel syndrome
    Mauro Mondelli
    Stefania Rossi
    Michele Ballerini
    Stefano Mattioli
    Neurological Sciences, 2013, 34 : 1197 - 1205
  • [46] Carpal tunnel syndrome: modern diagnostic and management techniques
    Kanaan, N
    Sawaya, RA
    BRITISH JOURNAL OF GENERAL PRACTICE, 2001, 51 (465) : 311 - 314
  • [47] Diagnostic potential of ultrasound in carpal tunnel syndrome with different etiologies: correlation of sonographic median nerve measures with electrodiagnostic severity
    Basant Elnady
    Elsayed M. Rageh
    Tohamy Ekhouly
    Sabry M. Fathy
    Mohamed Alshaar
    El Saeed Fouda
    Mohammed Attar
    Ahmed M. Abdelaal
    Ahmed El Tantawi
    Mohammed M. Algethami
    David Bong
    BMC Musculoskeletal Disorders, 20
  • [48] The Nerve/Tunnel Index: A New Diagnostic Standard for Carpal Tunnel Syndrome Using Sonography A Not Study
    Kim, Hyoung Seop
    Joo, Seung Ho
    Han, Zee-A
    Kim, Yong Wook
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (01) : 23 - 29
  • [49] Ultrasound-Guided Modified Thread Carpal Tunnel Release for Carpal Tunnel Syndrome: A Pilot Study
    Kim, Jaewon
    Kim, Jae Min
    Park, Hae-Yeon
    Kim, In Jong
    ULTRASCHALL IN DER MEDIZIN, 2025, 46 (01): : 57 - 65
  • [50] SONOGRAPHY IN CARPAL TUNNEL SYNDROME
    Hunderfund, Andrea N. Leep
    Boon, Andrea J.
    Mandrekar, Jayawant N.
    Sorenson, Eric J.
    MUSCLE & NERVE, 2011, 44 (04) : 485 - 491