Trabecular metal™ shoulder prosthesis in the treatment of complex proximal humeral fractures

被引:13
作者
Li, Fenglong [1 ]
Jiang, Chunyan [1 ]
机构
[1] Beijing Ji Shui Tan Hosp, Shoulder Serv, Beijing, Peoples R China
关键词
Proximal humeral fracture; Shoulder arthroplasty; Shoulder reconstruction; Trabecular metal; PRIMARY HEMIARTHROPLASTY; GLENOHUMERAL ABDUCTION; ARTHROPLASTY; OUTCOMES; REASONS; TRAUMA; HEAD;
D O I
10.1007/s00264-013-2061-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Shoulder arthroplasty is one of the options for the treatment of complex proximal humeral fractures. The purpose of this study was to assess the clinical and radiographic results of the trabecular metal shoulder prosthesis in the treatment of complex proximal humeral fractures. Methods Fifty-one consecutive patients with complex proximal humeral fractures who underwent primary shoulder arthroplasties with the trabecular metal (TM) prosthesis were enrolled in this study. At the final follow-up appointment, 42 of the patients (82.4 % of the total patients enrolled) were available for both clinical and radiographic evaluation. There were 28 women and 14 men with a mean age of 65.4 +/- 10.7 years. The dominant arm was involved in 30 of the cases. According to Neer's classification, there were seven three-part fractures, 27 four-part fractures and eight head-splitting fractures. Additionally, there were 37 hemiarthroplasties and five total shoulder arthroplasties. Results After a mean follow-up of 37.0 +/- 8.4 months (range 24-52 months), the average ranges of motion were: 38.6 +/- 15.0 degrees for external rotation, L3 level for internal rotation and 132.3 +/- 36.0 degrees for forward elevation. The mean American Shoulder and Elbow Surgeons, visual analogue scale and University of California, Los Angeles scores were 82.1 +/- 14.1, 0.4 +/- 1.1 and 28.8 +/- 5.1, respectively. The post-operative radiographs exhibited an anatomically attached greater tuberosity in 39 of the 42 shoulders. Of the three patients with greater tuberosity complications, as displayed by their radiographs, two were observed with malpositioned tuberosities, while the other greater tuberosity was resorbed. Proximal migration of the prosthesis was observed in all three shoulders with greater tuberosity complications and in two shoulders with an anatomically attached greater tuberosity. No neurovascular injury, infection or prosthetic loosening was identified during the final follow-up appointments. Conclusions Satisfactory results can be expected with the trabecular metal shoulder prosthesis for the treatment of complex proximal humeral fractures. The post-operative radiographs demonstrated an anatomically healed greater tuberosity in 93 % of the patients at a minimum follow-up time of two years.
引用
收藏
页码:2259 / 2264
页数:6
相关论文
共 28 条
[1]  
Anjum Syed Neshat, 2005, Acta Orthop Belg, V71, P388
[2]   Osteosynthesis and hemiarthroplasty of fractures of the proximal humerus: Outcomes in a consecutive case series [J].
Bastian, Johannes D. ;
Hertel, Ralph .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (02) :216-219
[3]   Tuberosity malposition and migration:: Reasons for poor outcomes after hemiarthroplasty for displaced fractures of the proximal humerus [J].
Boileau, P ;
Krishnan, SG ;
Tinsi, L ;
Walch, G ;
Coste, JS ;
Molé, D .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (05) :401-412
[4]   Shoulder arthroplasty for the treatment of the sequelae of fractures of the proximal humerus [J].
Boileau, P ;
Trojani, C ;
Walch, G ;
Krishnan, SG ;
Romeo, A ;
Sinnerton, R .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2001, 10 (04) :299-308
[5]  
COMPITO CA, 1994, CLIN ORTHOP RELAT R, P27
[6]   Prognostic factors in prosthetic replacement for acute proximal humerus fractures [J].
Demirhan, M ;
Kilicoglu, O ;
Altinel, L ;
Eralp, L ;
Akalin, Y .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (03) :181-188
[7]   Fixation of a Trabecular Metal Knee Arthroplasty Component A Prospective Randomized Study [J].
Dunbar, M. J. ;
Wilson, D. A. J. ;
Hennigar, A. W. ;
Amirault, J. D. ;
Gross, M. ;
Reardon, G. P. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (07) :1578-1586
[8]   Primary hemiarthroplasty in four-part fractures of the proximal humerus: Randomized trial of two different implant systems [J].
Fialka, Christian ;
Stampfl, Paul ;
Arbes, Stephanie ;
Reuter, Philippe ;
Oberleitner, Gerhard ;
Vecsei, Vilmos .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (02) :210-215
[9]   The clinical relevance of posttraumatic avascular necrosis of the humeral head [J].
Gerber, C ;
Hersche, O ;
Berberat, C .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (06) :586-590
[10]   Neer Award 2006: Biomechanical assessment of inferior tuberosity placement during hemiarthroplasty for four-part proximal humeral fractures [J].
Huffman, G. Russell ;
Itamura, John A. ;
McGarry, Michelle H. ;
Duong, Long ;
Gililland, Jeremy ;
Tibone, James E. ;
Lee, Thay Q. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (02) :189-196