Optimization of the structure of an electromagnetic calorimeter with longitudinal arrangement of absorbing and scintillating layers

被引:0
|
作者
Korablev, AV [1 ]
机构
[1] Inst High Energy Phys, Protvino 142284, Moscow Oblast, Russia
关键词
Physical Chemistry; Calorimeter; Geometric Parameter; Energy Resolution; Angular Dependence;
D O I
10.1023/A:1014579605149
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new layout of the absorbing and scintillating layers is proposed in order to suppress the channeling effect in an electromagnetic calorimeter where these layers are parallel to the beam. The energy resolution of this calorimeter is estimated for different geometric parameters. A weaker angular dependence is observed at angles >30 mrad.
引用
收藏
页码:6 / 8
页数:3
相关论文
共 9 条
  • [1] Optimization of the Structure of an Electromagnetic Calorimeter with Longitudinal Arrangement of Absorbing and Scintillating Layers
    A. V. Korablev
    Instruments and Experimental Techniques, 2002, 45 : 6 - 8
  • [2] An Electromagnetic Calorimeter with a Transversal Orientation of the Scintillating Fibers
    Yu. A. Bashmakov
    L. A. Gorbov
    M. S. Korbut
    A. I. Lebedev
    L. K. Lytkin
    S. V. Rusakov
    Instruments and Experimental Techniques, 2003, 46 : 462 - 466
  • [3] An electromagnetic calorimeter with a transversal orientation of the scintillating fibers
    Bashmakov, YA
    Gorbov, LA
    Korbut, MS
    Lebedev, AI
    Lytkin, LK
    Rusakov, SV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2003, 46 (04) : 462 - 466
  • [4] Longitudinal leakage correction of uniformly sampling electromagnetic calorimeter
    Li, ZH
    Chen, GM
    Chen, G
    Yang, CG
    Yang, M
    Wang, XB
    Zhang, SH
    Yang, ZY
    Lü, YS
    Chen, HS
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (11): : 1188 - 1192
  • [5] Study on angular resolution of lead-scintillating fiber electromagnetic calorimeter
    Wang, XB
    Chen, GM
    Li, ZH
    Chen, G
    Yang, M
    Yang, ZY
    Zhang, SH
    Lu, YS
    Chen, HS
    Li, XQ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (11): : 1071 - 1076
  • [6] Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter
    Li Zu-Hao
    Wang Ling-Yu
    Xu Wei-Wei
    Chen Guo-Ming
    Lu Yu-Sheng
    Chen He-Sheng
    CHINESE PHYSICS C, 2013, 37 (02)
  • [7] Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter
    李祖豪
    王玲玉
    许伟伟
    陈国明
    吕雨生
    陈和生
    Chinese Physics C, 2013, 37 (02) : 68 - 71
  • [8] Studies on high energy γ trigger of lead-scintillating fiber electromagnetic calorimeter
    Yang, ZY
    Chen, GM
    Chen, G
    Yang, M
    Wang, XB
    Liu, ZH
    Zhang, SH
    Lü, YS
    Chen, HS
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (10): : 1086 - 1089
  • [9] Monte Carlo study of the electromagnetic calorimeter optimization for MPD/NICA
    Marinova, B.
    Javadov, N.
    Tyapkin, I.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2015, 47 : 248 - 251