Corneal changes with accommodation using dual Scheimpflug photography

被引:25
作者
Siso-Fuertes, Irene [1 ]
Dominguez-Vicent, Alberto [2 ]
del Aguila-Carrasco, Antonio [2 ]
Ferrer-Blasco, Teresa [2 ]
Montes-Mico, Robert [2 ]
机构
[1] Univ Manchester, Fac Life Sci, Manchester, Lancs, England
[2] Univ Valencia, Optometry Res Grp, Opt Dept, Valencia, Spain
基金
欧洲研究理事会;
关键词
WAVE-FRONT ABERRATIONS; ANTERIOR; SHAPE; LENS; CURVATURE; PENTACAM; QUALITY; SEGMENT; EYE;
D O I
10.1016/j.jcrs.2014.08.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess whether corneal parameters and aberrations are affected by accommodation. SETTING: Optics Department, University of Valencia, Valencia, Spain. DESIGN: Prospective cross-sectional study. METHODS: The Galilei G4 dual Scheimpflug device was used to obtain data on the anterior and posterior axial curvatures, total corneal power (TCP), and corneal pachymetry from 3 corneal zones (central: 0.0 up to 4.0 mm; paracentral or mid: 4.0 up to 7.0 mm; peripheral: 7.0 up to 10.0 mm) in young emmetropic eyes in the unaccommodated and 4 accommodated states (from -1.0 to -4.0 diopters [D] in 1.0 D steps). The 2nd-, 3rd-, and 4th-order aberrations as well as the root mean square (RMS) were also determined for the entire cornea at the same accommodative demands. RESULTS: The study evaluated 7 subjects (12 eyes). No significant changes in any measured parameter were found during accommodation for any corneal zone (P>.05). Statistically significant differences were found in the various corneal zones when it was assumed they were constant with accommodation (P <.01). A stable linear trend with accommodation was also found for corneal aberrations, although individual variations existed because of the high standard deviation values. CONCLUSION: Different parameters in various zones of the cornea as well as corneal aberrations were stable during accommodation. (C) 2015 ASCRS and ESCRS
引用
收藏
页码:981 / 989
页数:9
相关论文
共 50 条
[31]   Evaluation of corneal elevation in eyes with subclinical keratoconus and keratoconus using Galilei double Scheimpflug analyzer [J].
Jafarinasab, Mohammad Reza ;
Feizi, Sepehr ;
Karimian, Farid ;
Hasanpour, Hossein .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (03) :377-384
[32]   Comparison of central corneal thickness measurements with the Galilei dual Scheimpflug analyzer and ultrasound pachymetry [J].
Ladi, Jeevan S. ;
Shah, Nitant A. .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (05) :385-388
[33]   Distinguishing Highly Asymmetric Keratoconus Eyes Using Dual Scheimpflug/Placido Analysis [J].
Golan, Oren ;
Piccinini, Andre L. ;
Hwang, Eric S. ;
Gonzalez, Ildamaris Montes De Oca ;
Krauthammer, Mark ;
Khandelwal, Sumitra S. ;
Smadja, David ;
Randleman, J. Bradley .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 201 :46-53
[34]   Normative Values for Corneal Densitometry Analysis by Scheimpflug Optical Assessment [J].
Dhubhghaill, Sorcha Ni ;
Rozema, Jos J. ;
Jongenelen, Sien ;
Hidalgo, Irene Ruiz ;
Zakaria, Nadia ;
Tassignon, Marie-Jose .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (01) :162-168
[35]   Changes of Corneal Topography Indices After CXL in Progressive Keratoconus Assessed by Scheimpflug Camera [J].
Kranitz, Kinga ;
Kovacs, Illes ;
Mihaltz, Kata ;
Sandor, Gabor Laszlo ;
Juhasz, Eva ;
Gyenes, Andrea ;
Nagy, Zoltan Zsolt .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (06) :374-378
[36]   Assessment of anterior and posterior corneal indices using two Scheimpflug analyzers [J].
Fahd, Daoud Charbel ;
Cherfan, Carole George ;
Raad, Claudia ;
Asouad, Marc ;
Awwad, Shady Tanus .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (01) :17-20
[37]   Comparison of Anterior Chamber Depth of Normal and Keratoconus Eyes Using Scheimpflug Photography [J].
Edmonds, Charles R. ;
Wung, Shu-Fen ;
Pemberton, Bart ;
Surrett, Steven .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (03) :120-122
[38]   Effect of white-to-white corneal diameter on biomechanical indices assessed by Pentacam Scheimpflug corneal tomography and corneal visualization Scheimpflug technology [J].
Lin, Qinghong ;
Shen, Zhengwei .
INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (05) :1537-1543
[39]   Effect of white-to-white corneal diameter on biomechanical indices assessed by Pentacam Scheimpflug corneal tomography and corneal visualization Scheimpflug technology [J].
Qinghong Lin ;
Zhengwei Shen .
International Ophthalmology, 2022, 42 :1537-1543
[40]   Scheimpflug photography keratometry readings for routine intraocular lens power calculation [J].
Shammas, H. John ;
Hoffer, Kenneth J. ;
Shammas, Maya C. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02) :330-334