Corneal changes with accommodation using dual Scheimpflug photography

被引:25
|
作者
Siso-Fuertes, Irene [1 ]
Dominguez-Vicent, Alberto [2 ]
del Aguila-Carrasco, Antonio [2 ]
Ferrer-Blasco, Teresa [2 ]
Montes-Mico, Robert [2 ]
机构
[1] Univ Manchester, Fac Life Sci, Manchester, Lancs, England
[2] Univ Valencia, Optometry Res Grp, Opt Dept, Valencia, Spain
基金
欧洲研究理事会;
关键词
WAVE-FRONT ABERRATIONS; ANTERIOR; SHAPE; LENS; CURVATURE; PENTACAM; QUALITY; SEGMENT; EYE;
D O I
10.1016/j.jcrs.2014.08.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess whether corneal parameters and aberrations are affected by accommodation. SETTING: Optics Department, University of Valencia, Valencia, Spain. DESIGN: Prospective cross-sectional study. METHODS: The Galilei G4 dual Scheimpflug device was used to obtain data on the anterior and posterior axial curvatures, total corneal power (TCP), and corneal pachymetry from 3 corneal zones (central: 0.0 up to 4.0 mm; paracentral or mid: 4.0 up to 7.0 mm; peripheral: 7.0 up to 10.0 mm) in young emmetropic eyes in the unaccommodated and 4 accommodated states (from -1.0 to -4.0 diopters [D] in 1.0 D steps). The 2nd-, 3rd-, and 4th-order aberrations as well as the root mean square (RMS) were also determined for the entire cornea at the same accommodative demands. RESULTS: The study evaluated 7 subjects (12 eyes). No significant changes in any measured parameter were found during accommodation for any corneal zone (P>.05). Statistically significant differences were found in the various corneal zones when it was assumed they were constant with accommodation (P <.01). A stable linear trend with accommodation was also found for corneal aberrations, although individual variations existed because of the high standard deviation values. CONCLUSION: Different parameters in various zones of the cornea as well as corneal aberrations were stable during accommodation. (C) 2015 ASCRS and ESCRS
引用
收藏
页码:981 / 989
页数:9
相关论文
共 50 条
  • [1] Evaluation of corneal changes with accommodation in young and presbyopic populations using Pentacam High Resolution Scheimpflug system
    Ni, Yao
    Liu, Xialin
    Lin, Ying
    Guo, Xiaobo
    Wang, Xueqin
    Liu, Yizhi
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 (03) : 244 - 250
  • [2] Corneal topography and keratoconus diagnostics with Scheimpflug photography
    Buehren, J.
    OPHTHALMOLOGE, 2014, 111 (10): : 920 - 926
  • [3] Measuring Corneal Haze by Using Scheimpflug Photography and Confocal Microscopy
    McLaren, Jay W.
    Wacker, Katrin
    Kane, Katrina M.
    Patel, Sanjay V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (01) : 227 - 235
  • [4] Intraobserver and interobserver repeatability of curvature and aberrometric measurements of the posterior corneal surface in normal eyes using Scheimpflug photography
    Pinero, David P.
    Saenz Gonzalez, Cristina
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) : 113 - 120
  • [5] Dual-Scheimpflug-Placido-disc corneal analysis in cats
    de Andrade Ramos, Leticia
    Seullner Brandao, Claudia Valeria
    Guillermo Arce, Carlos
    Haddad Pinho, Renata
    Garbelotti Goncalves, Lenise
    Padovani, Carlos Roberto
    VETERINARY OPHTHALMOLOGY, 2022, 25 (05) : 360 - 366
  • [6] Repeatability of corneal power and wavefront aberration measurements with a dual-Scheimpflug Placido corneal topographer
    Wang, Li
    Shirayama, Mariko
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (03) : 425 - 430
  • [7] Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement
    Kawamorita, Takushi
    Uozato, Hiroshi
    Kamiya, Kazutaka
    Bax, Leon
    Tsutsui, Kenta
    Aizawa, Daisuke
    Shimizu, Kimiya
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) : 127 - 133
  • [8] Comparison of Corneal Power and Corneal Astigmatism of Different Diameter Zones Centered on the Pupil and Corneal Apex Using Scheimpflug Tomography
    Dong, Jing
    Zhang, Yaqin
    Zhou, Jing
    Zhang, Suhua
    Sun, Bin
    Tang, Maolong
    Wang, Xiaogang
    CORNEA, 2020, 39 (01) : 77 - 83
  • [9] Intrasubject repeatability of corneal morphology measurements obtained with a new Scheimpflug photography-based system
    Montalban, Raul
    Pinero, David P.
    Javaloy, Jaime
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06) : 971 - 977
  • [10] Corneal powers measured with a rotating Scheimpflug camera
    Naeser, Kristian
    Savini, Giacomo
    Bregnhoj, Jesper Flethoj
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (09) : 1196 - 1200