Prevalence of Legionella Strains in Cooling Towers and Legionellosis Cases in New Zealand

被引:2
作者
Lau, Robert [1 ]
Maqsood, Saadia
Harte, David [2 ]
Caughley, Brian
Deacon, Rob [3 ]
机构
[1] Massey Univ Wellington, Coll Sci, Wellington 6021, New Zealand
[2] Inst Environm Sci & Res, Porirua, New Zealand
[3] Environm Lab Serv, Lower Hutt, New Zealand
关键词
LEGIONNAIRES-DISEASE; POTTING MIX; OUTBREAK; PNEUMOPHILA;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Over 3,900 water samples from 688 cooling towers were tested for Legionella in 2008 in New Zealand. Of 80 (2.05% isolation rate) Legionella isolates, 10 (12.5%) were L. pneumophila serogroup 1; 10 (12.5%) were L. anisa; nine (11.2%) were L. pneumophila serogroup 8; and one (1.2%) was L. longbeachae serogroup 2. Forty-one (51.2%) Legionella isolates were L. pneumophila serogroups. Over 3,990 water samples from 606 cooling towers were tested for Legionella in 2009 in New Zealand. Of 51 (1.28% isolation rate) Legionella isolates, 18 (35.3%) were L. pneumophila serogroup 1, and 39 (76.4%) were other L. pneumophila serogroups. L. pneumophila serogroups were significantly associated with legionellosis cases in 2008 and 2009. L. longbeachae serogroups were equally significantly associated with legionellosis cases. This significant association of L. longbeachae with legionellosis particularly of L. longbeachae serogroup 1 is unique in that part of the world. The authors' study also showed that the aqueous environment of the cooling tower is not a natural habitat for pathogenic L. longbeachae. Regular monitoring and maintenance of cooling towers have prevented outbreaks of legionellosis.
引用
收藏
页码:82 / 89
页数:8
相关论文
共 26 条
[1]   COMMUNITY-ACQUIRED LEGIONNAIRES-DISEASE ASSOCIATED WITH A COOLING-TOWER - EVIDENCE FOR LONGER-DISTANCE TRANSPORT OF LEGIONELLA-PNEUMOPHILA [J].
ADDISS, DG ;
DAVIS, JP ;
LAVENTURE, M ;
WAND, PJ ;
HUTCHINSON, MA ;
MCKINNEY, RM .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1989, 130 (03) :557-568
[2]  
[Anonymous], 2005, LEG ENV LEG
[3]  
[Anonymous], 2000, 3666 ASNZS 3
[4]  
[Anonymous], 2008, 38962008 ASNZS
[5]  
[Anonymous], 2007, 4276312007 ASNZS
[6]  
[Anonymous], 2018, 2006 CENS POP DWELL
[7]   Routine sampling and the control of Legionella spp. in cooling tower water systems [J].
Bentham, RH .
CURRENT MICROBIOLOGY, 2000, 41 (04) :271-275
[8]   False-positive Legionella titres in routine clinical serology testing detected by absorption with campylobacter: Implications for the serological diagnosis of Legionnaires' disease [J].
Boswell, TCJ ;
Marshall, LE ;
Kudesia, G .
JOURNAL OF INFECTION, 1996, 32 (01) :23-26
[9]   A community outbreak of Legionnaires' disease linked to hospital cooling towers: an epidemiological method to calculate dose of exposure [J].
Brown, CM ;
Nuorti, PJ ;
Breiman, RF ;
Hathcock, AL ;
Fields, BS ;
Lipman, HB ;
Llewellyn, GC ;
Hofmann, J ;
Cetron, M .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1999, 28 (02) :353-359
[10]   Analysis of the Legionella longbeachae Genome and Transcriptome Uncovers Unique Strategies to Cause Legionnaires' Disease [J].
Cazalet, Christel ;
Gomez-Valero, Laura ;
Rusniok, Christophe ;
Lomma, Mariella ;
Dervins-Ravault, Delphine ;
Newton, Hayley J. ;
Sansom, Fiona M. ;
Jarraud, Sophie ;
Zidane, Nora ;
Ma, Laurence ;
Bouchier, Christiane ;
Etienne, Jerome ;
Hartland, Elizabeth L. ;
Buchrieser, Carmen .
PLOS GENETICS, 2010, 6 (02)