Fundus-simulating phantom for calibration of retinal vessel oximetry devices

被引:5
作者
Chen, Hongyu [1 ]
Liu, Guangu [1 ]
Zhang, Shulin [1 ]
Shen, Shuwei [1 ]
Lu, Yuhao [1 ]
Li, Jialuo [1 ]
Roberts, Cynthia J. [2 ]
Sun, Mingzhai [1 ]
Xu, Ronald X. [1 ,3 ]
机构
[1] Univ Sci & Technol China, Sch Engn Sci, Hefei 230027, Anhui, Peoples R China
[2] Ohio State Univ, Dept Ophthalmol & Visual Sci, Columbus, OH 43212 USA
[3] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
基金
中国国家自然科学基金;
关键词
OXYGEN-SATURATION; REFLECTANCE; HEMOGLOBIN; FLOW;
D O I
10.1364/AO.58.003877
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Retinal vessel oxygen supply is important for retinal tissue metabolism. Commonly used retinal vessel oximetry devices are based on dual-wavelength spectral measurement of oxyhemoglobin and deoxyhemoglobin. However, there is no traceable standard for reliable calibration of these devices. In this study, we developed a fundus-simulating phantom that closely mimicked the optical properties of human fundus tissues. Microchannels of precisely controlled topological structures were produced by soft lithography to simulate the retinal vasculature. Optical properties of the phantom were adjusted by adding scattering and absorption agents to simulate different concentrations of fundus pigments. The developed phantom was used to calibrate the linear correlation between oxygen saturation (SO2) level and optical density ratio in a dual-wavelength oximetry device. The obtained calibration factors were used to calculate the retinal vessel SO2 in both eyes of five volunteers aged between 24 and 27 years old. The test results showed that the mean arterial and venous SO2 levels after phantom calibration were coincident with those after empirical value calibration, indicating the potential clinical utility of the produced phantom as a calibration standard. (C) 2019 Optical Society of America
引用
收藏
页码:3877 / 3885
页数:9
相关论文
共 38 条
[1]   Oxygen-dependent diseases in the retina: Role of hypoxia-inducible factors [J].
Arjamaa, Olli ;
Nikinmaa, Mikko .
EXPERIMENTAL EYE RESEARCH, 2006, 83 (03) :473-483
[2]   Shape of the retinal surface in emmetropia and myopia [J].
Atchison, DA ;
Pritchard, N ;
Schmid, KL ;
Scott, DH ;
Jones, CE ;
Pope, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (08) :2698-2707
[3]   Pathway to Retinal Oximetry [J].
Beach, James .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2014, 3 (05)
[4]   Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation [J].
Beach, JM ;
Schwenzer, KJ ;
Srinivas, S ;
Kim, D ;
Tiedeman, JS .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) :748-758
[5]   Fundus reflectance - historical and present ideas [J].
Berendschot, TTJM ;
DeLint, PJ ;
van Norren, D .
PROGRESS IN RETINAL AND EYE RESEARCH, 2003, 22 (02) :171-200
[6]   Fabrication of a turbid optofluidic phantom device with tunable μα and μs′ to simulate cutaneous vascular perfusion [J].
Chen, Chen ;
Ahmed, Midhat ;
Haefner, Tom ;
Klaempfl, Florian ;
Stelzle, Florian ;
Schmidt, Michael .
SCIENTIFIC REPORTS, 2016, 6
[7]   SPECTRAL REFLECTANCE OF THE HUMAN OCULAR FUNDUS [J].
DELORI, FC ;
PFLIBSEN, KP .
APPLIED OPTICS, 1989, 28 (06) :1061-1077
[8]   Evaluation of a pointwise microcirculation assessment method using liquid and multilayered tissue simulating phantoms [J].
Fredriksson, Ingemar ;
Saager, Rolf B. ;
Durkin, Anthony J. ;
Stromberg, Tomas .
JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
[9]   Rapid prototyping of biomimetic vascular phantoms for hyperspectral reflectance imaging [J].
Ghassemi, Pejhman ;
Wang, Jianting ;
Melchiorri, Anthony J. ;
Ramella-Roman, Jessica C. ;
Mathews, Scott A. ;
Coburn, James C. ;
Sorg, Brian S. ;
Chen, Yu ;
Pfefer, T. Joshua .
JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (12)
[10]   OPTICAL-PROPERTIES OF OCULAR FUNDUS TISSUES - AN IN-VITRO STUDY USING THE DOUBLE-INTEGRATING-SPHERE TECHNIQUE AND INVERSE MONTE-CARLO SIMULATION [J].
HAMMER, M ;
ROGGAN, A ;
SCHWEITZER, D ;
MULLER, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06) :963-978