Endovascular stent graft repair of aortogastric fistula caused by peptic ulcer after esophagectomy A case report

被引:6
作者
Wei, Xiao-Qing [1 ]
Song, Lei [1 ]
Zhang, Xue-Song [1 ]
Wang, Kui-Yang [1 ]
Wu, Jie [1 ]
机构
[1] Dalian Med Univ, Hosp 2, Intervent Therapy Dept, Dalian, Peoples R China
关键词
aortogastric fistula; endovascular stent graft repair; esophagectomy; gastric tube ulceration; SURGICAL-TREATMENT; AORTOESOPHAGEAL FISTULA;
D O I
10.1097/MD.0000000000008959
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rationale: Aortogastric fistula (AGF) is a rare but devastating clinical complication after esophagectomy. In a recent report, nearly all AGF patients died of massive hemorrhage or aspiration of massive hematemesis. Therefore, timely appropriate treatment of AGF remains a challenge. Herein, we report a case of AGF that resulted from peptic ulceration after esophagectomy and was successfully treated with endovascular stent graft placement. Patient concerns: A 59-year-old man had undergone video-assisted thoracoscopic esophagectomy for squamous cell carcinoma and esophageal reconstruction using a gastric tube 14 months previously. He suddenly experienced massive hematemesis and unstable circulatory dynamics, Infusion was performed to treat critical hemorrhagic shock but was ineffective. We informed the patient and his family members of the situation, and once written informed consent to treatment was provided, we rushed him to the operating room. Diagnoses: Contrast medium permeated into the gastric cavity through a fistula between the abdominal aorta and gastric tube at the 11th thoracic level, Based on this, we made a diagnosis of AGF resulting from a peptic ulcer, and this diagnosis was further confirmed by high pressure angiography combined with computed tomography (CT) imaging. Interventions: An endovascular stent graft was placed under the guidance of digital subtraction angiography and followed by antibiotic therapy to prevent infection and proton pump inhibitor therapy to inhibit gastric acid secretion. Outcomes: The patient recovered uneventfully after the procedure. Four months after surgery, the patient died of organ failure caused by retroperitoneal lymph node metastasis and multiple intrahepatic metastases, with no postoperative bleeding linked to the endovascular stent graft repair. Lessons: Our case supports the notion that endovascular stent graft repair is a feasible alternative in treatment of AGF with several advantages in addition to surgical intervention, although more such cases should be collected and analyzed in the future to corroborate our observations.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Successful management following combined thoracic endovascular aortic repair and minimally invasive esophagectomy for primary aortoesophageal fistula: A case report
    Yokoe, Takeshi
    Toiyama, Yuji
    Ichikawa, Takashi
    Uratani, Ryo
    Imaoka, Hiroki
    Yasuda, Hiromi
    Morimoto, Yuki
    Fujikawa, Hiroyuki
    Okugawa, Yoshinaga
    Okita, Yoshiki
    Yoshiyama, Shigeyuki
    Ohi, Masaki
    ASIAN JOURNAL OF ENDOSCOPIC SURGERY, 2024, 17 (01)
  • [22] Leg Ulcer as a Complication of a Posttraumatic Tibial Arteriovenous Fistula Treated by Endovascular Approach With Stent-Graft Placement
    Rabellino, Martin
    Shinzato, Sergio
    Aragon-Sanchez, Javier
    Peralta, Oscar
    Marenchino, Ricardo
    Garcia-Monaco, Ricardo
    INTERNATIONAL JOURNAL OF LOWER EXTREMITY WOUNDS, 2012, 11 (03) : 147 - 151
  • [23] Lethal Hemorrhage Caused by Aortoesophageal Fistula Secondary to Stent-Graft Repair of the Thoracic Aorta
    Hendrik B. Sager
    Peter Wellhöner
    Johanna A. Wermelt
    Heribert Schunkert
    Volkhard Kurowski
    CardioVascular and Interventional Radiology, 2011, 34 : 60 - 63
  • [24] Lethal Hemorrhage Caused by Aortoesophageal Fistula Secondary to Stent-Graft Repair of the Thoracic Aorta
    Sager, Hendrik B.
    Wellhoener, Peter
    Wermelt, Johanna A.
    Schunkert, Heribert
    Kurowski, Volkhard
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 : S60 - S63
  • [25] Refractory Ulcer of Reconstructed Gastric Tube after Esophagectomy: A Case Report
    Okamura, Yuki
    Takeno, Shinsuke
    Takahashi, Yoshiaki
    Moroga, Toshihiko
    Yamashita, Shin-ichi
    Kawahara, Katsunobu
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 19 (02) : 136 - 139
  • [26] Laparoscopic repair of parahiatal hernia after esophagectomy: a case report
    Yuji Akiyama
    Takeshi Iwaya
    Fumitaka Endo
    Takehiro Chiba
    Takeshi Takahara
    Koki Otsuka
    Hiroyuki Nitta
    Keisuke Koeda
    Masaru Mizuno
    Yusuke Kimura
    Akira Sasaki
    Surgical Case Reports, 3 (1)
  • [27] Endovascular stent-graft treatment for aortoesophageal fistula induced by an esophageal fishbone: Two cases report
    Gong, Hang
    Wei, Wei
    Huang, Zhong
    Hu, Ying
    Liu, Xian-Li
    Hu, Zhen
    WORLD JOURNAL OF CLINICAL CASES, 2022, 10 (07) : 2206 - 2215
  • [28] Thoracic aortic aneurysm complicated by secondary aortoesophageal fistula after thoracic endovascular aortic repair : a case report
    Spitaels, R.
    Jacob, W.
    Janssens, F.
    Schurmans, P.
    Vanmoerkerke, I.
    Walgraeve, D.
    Coenegrachts, J. -L.
    ACTA GASTRO-ENTEROLOGICA BELGICA, 2017, 80 (04) : 527 - 529
  • [29] Massive hemorrhage from an aortoesophageal fistula caused by esophageal stent implantation A case report and literature review
    Zhan, Yefei
    Xu, Zhaojun
    Degree, Bachelor
    MEDICINE, 2019, 98 (51)
  • [30] Surgical treatment of an aortoesophageal fistula caused by stent implantation for esophageal stenosis: Report of a case
    Unosawa, Satoshi
    Hata, Mitsumasa
    Sezai, Akira
    Niino, Tetsuya
    Yoda, Masataka
    Shimura, Kazuma
    Furukawa, Nobuyuki
    Minami, Kazutomo
    SURGERY TODAY, 2008, 38 (01) : 62 - 64