Influence of lesion length on restenosis after coronary stent placement

被引:158
作者
Kastrati, A
Elezi, S
Dirschinger, J
Hadamitzky, M
Neumann, FJ
Schömig, A
机构
[1] Deutsch Herzzentrum, D-80636 Munich, Germany
[2] Tech Univ Munich, Med Klin Rechts Isar, Munich, Germany
关键词
D O I
10.1016/S0002-9149(99)00165-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The length of a coronary lesion is a significant predictor of restenosis after balloon angioplasty. The influence of lesion length has not comprehensively been assessed after coronary stent placement. This study includes 2,736 consecutive patients with coronary stent placement. Only patients with recent or chronic occlusions before the intervention were excluded. Patients were divided in 2 groups: 573 patients with long lesions (greater than or equal to 15 mm) and 2,163 patients with short lesions (<15 mm). There were no significant differences between the groups with respect to the procedural success rate and incidence of subacute thrombosis. One-year event-free survival was lower in patients with long lesions (73.3% vs 80.0%, p = 0.001). Six-month angiography was performed in 82.5% of the eligible patients. The incidence of binary restenosis (greater than or equal to 50% diameter stenosis) was higher in patients with long lesions (36.9% vs 27.9%, p < 0.001). Similarly, patients with long lesions presented more late lumen loss than those with short lesions (1.29 +/- 0.89 vs 1.07 +/- 0.77 mm, p < 0.001). Multivariate models for both binary restenosis and late lumen loss demonstrated that lesion length was an independent risk factor for restenosis. The risk was further increased by multiple stent placement and overlapping stents that were also independent risk factors of restenosis. Stented segment length did not show any independent effect. Therefore, long lesions represent an independent risk factor for restenosis after coronary stent placement. The results of this study suggest that a possible way to reduce the risk is to cover the lesion with a minimal number of nonoverlapping stents. (C) 1999 by Excerpta Medica, Inc.
引用
收藏
页码:1617 / 1622
页数:6
相关论文
共 50 条
  • [41] The impact of lesion length and vessel size on outcomes after sirolimus-eluting stent implantation for in-stent restenosis
    Habara, S.
    Mitsudo, K.
    Goto, T.
    Kadota, K.
    Fujii, S.
    Yamamoto, H.
    Kato, H.
    Takenaka, S.
    Fuku, Y.
    Hosogi, S.
    Hirono, A.
    Yamamoto, K.
    Tanaka, H.
    Hasegawa, D.
    Nakamura, Y.
    Tasaka, H.
    Otsuru, S.
    Okamoto, Y.
    Yamada, C.
    Miyamoto, M.
    Inoue, K.
    HEART, 2008, 94 (09) : 1162 - 1165
  • [42] Carotid angioplasty and stent placement for restenosis after endarterectomy
    Yasha Kadkhodayan
    Christopher J. Moran
    Colin P. Derdeyn
    DeWitte T. Cross
    Neuroradiology, 2007, 49 : 357 - 364
  • [43] Carotid angioplasty and stent placement for restenosis after endarterectomy
    Kadkhodayan, Yasha
    Moran, Christopher J.
    Derdeyn, Colin P.
    Cross, DeWitte T., III
    NEURORADIOLOGY, 2007, 49 (04) : 357 - 364
  • [44] Predictive factors for early cardiac events and angiographic restenosis after coronary stent placement in small coronary arteries
    Hausleiter, J
    Kastrati, A
    Mehilli, J
    Schühlen, H
    Pache, J
    Dotzer, F
    Dirschinger, J
    Schömig, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (05) : 882 - 889
  • [45] Abciximab (c7E3) and angiographic restenosis after coronary stent placement
    Hausleiter, J
    Schuhlen, H
    Walter, H
    Elezi, S
    Hadamitzky, M
    Dirschinger, J
    Neumann, FJ
    Schomig, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 10828 - 10828
  • [46] Predictors of restenosis after coronary stent implantation
    Bauters, C
    Hubert, E
    Prat, A
    Bougrimi, K
    Van Belle, E
    McFadden, EP
    Amouyel, P
    Lablanche, JM
    Bertrand, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) : 1291 - 1298
  • [47] Insertion/deletion polymorphism of the angiotensin-converting enzyme and restenosis after coronary stent placement
    Kastrati, A
    Koch, W
    Elezi, S
    Kettling, C
    Mehilli, J
    von Beckerath, N
    Schomig, A
    Herzzentrum, D
    CIRCULATION, 1998, 98 (17) : 433 - 433
  • [48] Effectiveness and safety of sirolimus-eluting stents in the treatment of restenosis after coronary stent placement
    Neumann, FJ
    Desmet, W
    Grube, E
    Brachmann, J
    Presbitero, P
    Rubartelli, P
    Mügge, A
    Di Pede, F
    Füllgraf, D
    Aengevaeren, W
    Spedicato, L
    Popma, JJ
    CIRCULATION, 2005, 111 (16) : 2107 - 2111
  • [49] Influence of residual stenosis after percutaneous coronary intervention with stent implantation on development of restenosis and stent thrombosis
    Sick, P
    Hüttl, T
    Niebauer, J
    Thiele, H
    Lauer, B
    Harnbrecht, R
    Hentschel, B
    Schuler, G
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (02) : 148 - 153
  • [50] VERY EARLY IN-STENT RESTENOSIS AFTER A BARE METAL STENT PLACEMENT
    Tyagi, Gaurav
    Minnelli, Carrie
    Azarbaijani, Ramin Assadi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A684 - A684