Self-Assembled Quantum Dot Based Swept Laser Source for Optical Coherence Tomography Applications

被引:1
|
作者
Peyvast, N. [1 ]
Childs, D. T. D. [1 ]
Krstajic, N. [2 ,4 ]
Lu, Z. [2 ]
Matcher, S. J. [2 ]
Livshits, D. [3 ]
Shkolnik, A. [3 ]
Krestnikov, I. [3 ]
Hogg, R. A. [1 ]
机构
[1] Univ Sheffield, Elect & Elect Engn Dept, Sheffield S10 2TN, S Yorkshire, England
[2] Univ Sheffield, Dept Mat Sci & Engn, Sheffield S10 2TN, S Yorkshire, England
[3] Innolume GmbH, Dortmund, Germany
[4] Univ Edinburgh, Sch Engn, Edinburgh EH8 9YL, Midlothian, Scotland
来源
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI | 2012年 / 8213卷
关键词
swept-laser; SOA; quantum dot; quantum well; skin; OCT; AMPLIFIERS;
D O I
10.1117/12.907977
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work the use of two identical QD SOAs to enhance the performance of swept laser system for OCT applications is discussed, resulting in an increase in bandwidth up to 94nm. The combination of GaAs based QD SOAs and InP based QW SOAs for realizing broad bandwidth sources for OCT system is described. For the swept laser source a 154nm spectral bandwidth from 1193nm to 1347nm and an average power of 8mW is obtained and for the filtered ASE source a 225 nm bandwidth is demonstrated.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Swept source optical coherence tomography imaging of a series of choroidal tumours
    Filloy, Alejandro
    Caminal, Josep M.
    Arias, Luis
    Jordan, Sara
    Catala, Jaume
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2015, 50 (03): : 242 - 248
  • [22] Gastric and Colon Cancer Imaging with Swept Source Optical Coherence Tomography
    Luo, Site
    Liu, Hao
    Zhao, Hui
    An, Xin
    Xie, Huikai
    Huo, Li
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [23] A study on optical coherence tomography using high frequency swept source
    Ding, Lei
    Tong, Xinglin
    Chen, Liang
    Hu, Pan
    Huang, Di
    Zhao, Minli
    Wen, Hongqiao
    IMAGE SENSING TECHNOLOGIES: MATERIALS, DEVICES, SYSTEMS, AND APPLICATIONS III, 2016, 9854
  • [24] Optical power transmission in a polygon mirror-based swept source optical coherence tomography system
    Everson, Michael
    Duma, Virgil-Florin
    Dobre, George
    DIGITAL OPTICAL TECHNOLOGIES 2017, 2017, 10335
  • [25] Swept source optical coherence tomography of objects with arbitrary reflectivity profiles
    Mezgebo, Biniyam
    Nagib, Karim
    Fernando, Namal
    Kordi, Behzad
    Sherif, Sherif
    2ND CANTERBURY CONFERENCE ON OCT WITH EMPHASIS ON BROADBAND OPTICAL SOURCES, 2018, 10591
  • [26] Characterization of a fibre optic swept laser source at 1 μm for optical coherence tomography imaging systems
    Trifanov, Irina
    Neagu, Liviu
    Bradu, Adrian
    Ribeiro, Antonio Lobo
    Podoleanu, Adrian Gh.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [27] Swept-source visible-light optical coherence tomography
    Fan, Weijia
    Kuranov, Roman
    Miller, David a.
    Zhang, Tingwei
    Yeo, Wei-hong
    Atkinson, Raymond
    Zhang, Pengpeng
    Sun, Cheng
    Zhang, Hao f.
    OPTICS LETTERS, 2025, 50 (03) : 928 - 931
  • [28] Optical transitions in self-assembled quantum dots
    Gondar, JL
    Comas, F
    PHYSICA B-CONDENSED MATTER, 2002, 322 (3-4) : 413 - 418
  • [29] Ultrafast coherent spectroscopy of a single self-assembled quantum dot
    Wolpert, Christian
    Dicken, Christian
    Wang, Lijuan
    Atkinson, Paola
    Rastelli, Armando
    Schmidt, Oliver G.
    Giessen, Harald
    Lippitz, Markus
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2012, 249 (04): : 721 - 730
  • [30] Wide field and highly sensitive angiography based on optical coherence tomography with akinetic swept source
    Xu, Jingjiang
    Song, Shaozhen
    Wei, Wei
    Wang, Ruikang K.
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (01): : 420 - 435