Root canal filling materials spread pattern mimicking root fractures in dental CBCT images

被引:18
作者
Iikubo, Masahiro [1 ]
Osano, Takashi [2 ]
Sano, Tsukasa [3 ]
Katsumata, Akitoshi [4 ]
Ariji, Eiichiro [5 ]
Kobayashi, Kaoru [2 ]
Sasano, Takashi [1 ]
Wakoh, Mamoru [6 ]
Seki, Kenji [3 ]
Kojima, Ikuho [1 ]
Sakamoto, Maya [1 ]
机构
[1] Tohoku Univ, Grad Sch Dent, Dept Oral Diag, Sendai, Miyagi 9808575, Japan
[2] Tsurumi Univ, Sch Dent Med, Dept Oral & Maxillofacial Radiol & Diag, Yokohama, Kanagawa, Japan
[3] Showa Univ, Sch Dent, Dept Oral Diagnost Sci, Div Radiol, Tokyo 142, Japan
[4] Asahi Univ, Sch Dent, Dept Oral Radiol, Mizuho, Japan
[5] Aichi Gakuin Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Nagoya, Aichi 464, Japan
[6] Tokyo Dent Coll, Dept Oral & Maxillofacial Radiol, Tokyo, Japan
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2015年 / 120卷 / 04期
关键词
BEAM COMPUTED-TOMOGRAPHY; PERIAPICAL RADIOGRAPHY; INTRAORAL RADIOGRAPHY; CT; ARTIFACTS; ACCURACY; TEETH;
D O I
10.1016/j.oooo.2015.06.030
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To clarify the cause of artificial tooth-root fracture lines in cone beam computed tomography (CBCT) images caused by root canal filling materials and to enhance the diagnostic performance of CBCT. Study Design. We analyzed the CBCT images of 18 extracted human teeth (9 upper central incisors and 9 lower premolars) that were filled with a size 50 gutta-percha cone and inserted into tooth sockets in a human skull. Results. The CBCT images of the incisors displayed artificial lines in the oblique directions, notably the mesiobuccal, distolingual, distobuccal and mesiolingual directions, but only rarely in the cross-directions (buccal, lingual, mesial, and distal). In the premolars, the reverse was true, with lines mainly in the cross-directions, mesial and distal directions particularly. The lines were predominantly at the cervical slice. Conclusions. Artifacts resulting from root filling material appear along the long axis of the alveolar bones, and resemble root fractures.
引用
收藏
页码:521 / 527
页数:7
相关论文
共 25 条
[1]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[2]   Metal artefact reduction with cone beam CT: an in vitro study [J].
Bechara, B. B. ;
Moore, W. S. ;
McMahan, C. A. ;
Noujeim, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (03) :248-253
[3]   In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography [J].
Benic, Goran I. ;
Sancho-Puchades, Manuel ;
Jung, Ronald E. ;
Deyhle, Hans ;
Haemmerle, Christoph H. F. .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) :378-383
[4]  
Boas FE., 2012, IMAGING MED, V4, P229, DOI DOI 10.2217/IIM.12.13
[5]   Ex vivo evaluation of artifacts mimicking fracture lines on cone-beam computed tomography produced by different root canal sealers [J].
Brito-Junior, M. ;
Santos, L. A. N. ;
Faria-e-Silva, A. L. ;
Pereira, R. D. ;
Sousa-Neto, M. D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (01) :26-31
[6]   Beam hardening artefacts occur in dental implant scans with the NewTom® cone beam CT but not with the dental 4-row multidetector CT [J].
Draenert, F. G. ;
Coppenrath, E. ;
Herzog, P. ;
Muller, S. ;
Mueller-Lisse, U. G. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (04) :198-203
[7]   Accuracy of cone beam computed tomography and panoramic and periapical radiography for detection of apical periodontitis [J].
Estrela, Carlos ;
Bueno, Mike Reis ;
Leles, Claudio Rodrigues ;
Azevedo, Bruno ;
Azevedo, Jose Ribamar .
JOURNAL OF ENDODONTICS, 2008, 34 (03) :273-279
[8]  
Ezzodini Ardakani Fatemeh, 2015, Iran Endod J, V10, P122
[9]   Comparison of intraoral radiography and cone-beam computed tomography for the detection of vertical root fractures: an in vitro study [J].
Gunduz, Kaan ;
Avsever, Hakan ;
Orhan, Kaan ;
Celenk, Peruze ;
Ozmen, Bilal ;
Cicek, Ersan ;
Egrioglu, Erol ;
Karacayli, Umit .
ORAL RADIOLOGY, 2013, 29 (01) :6-12
[10]   Comparison of image validity between cone beam computed tomography for dental use and multidetector row helical computed tomography [J].
Hashimoto, K. ;
Kawashima, S. ;
Kameoka, S. ;
Akiyama, Y. ;
Honjoya, T. ;
Ejima, K. ;
Sawada, K. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (08) :465-471