Design of radiant floor heating panel in view of floor surface temperatures

被引:80
作者
Shin, Mi Su [1 ]
Rhee, Kyu Nam [1 ]
Ryu, Seong Ryong [2 ]
Yeo, Myoung Souk [3 ]
Kim, Kwang Woo [3 ]
机构
[1] Seoul Natl Univ, Grad Sch, Dept Architecture, Coll Engn, Seoul 151744, South Korea
[2] Kumoh Natl Inst Technol, Sch Architecture, Gumi 730701, Gyeongbuk, South Korea
[3] Seoul Natl Univ, Dept Architecture, Coll Engn, Seoul 151744, South Korea
基金
新加坡国家研究基金会;
关键词
Radiant floor heating panel; Design; Heat flux; Floor surface temperature; Difference between maximum and minimum floor surface temperature (DFST); Maximum floor surface temperature (MFST); SYSTEM;
D O I
10.1016/j.buildenv.2015.05.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The radiant floor heating panel should be designed to maintain the indoor condition within the comfort range, to prevent discomfort when contacting floor surfaces of uneven temperature distribution, and to prevent skin burn and unwanted deformation of materials. For these reasons, heat flux and floor surface temperature distribution should be examined at the design stage. However, the current design convention focuses mainly on securing enough heat flux and not much of attention is given to floor surface temperature distribution. In this study, design charts were developed that help designers to consider heat flux, difference between maximum and minimum floor surface temperature (DFST), and maximum floor surface temperature (MFST) at the design stage through investigating the relationships between heat flux and design parameters and conducting numerical simulations to analyze floor surface temperature distributions. These charts were validated through experiments. Then some applications and limitations were suggested for utilizing the design charts. The design charts can be applied to panels with no floor covering, linoleum and oak wood as floor coverings. Design alternatives for other floor coverings can also be developed by interpolating the values from the design charts, because there are linear relationships between the required average water temperature and heat flux. The results of this study can be used to examine the designed panel to verify whether it can provide enough heat flux and that DFST and MFST are appropriate. Additionally, the developed design charts help the designer to compare design alternatives, thus enhancing the flexibility of the panel design. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:559 / 577
页数:19
相关论文
共 50 条
  • [41] Experimental Investigations on Thermal Performance of a New Floor Heating Device
    Wang, Yu
    Zhang, Zhigang
    He, Falong
    Liu, Xueli
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 2132 - 2140
  • [42] Field evaluation of performance of radiant heating/cooling ceiling panel system
    Li, Rongling
    Yoshidomi, Togo
    Ooka, Ryozo
    Olesen, Bjarne W.
    ENERGY AND BUILDINGS, 2015, 86 : 58 - 65
  • [43] Dynamic variation of surface temperatures on the radiant ceiling cooling panel based on the different supply water temperature adjustments
    Jin, Wufeng
    Ma, Jingda
    Jia, Lizhi
    Wang, Zhiqiang
    SUSTAINABLE CITIES AND SOCIETY, 2020, 52
  • [44] Investigating the effect of solar heat gain on intermittent operation characteristics of radiant cooling floor
    Zhao, Kang
    Lv, Guoquan
    Shen, Cheng
    Ge, Jian
    ENERGY AND BUILDINGS, 2022, 255
  • [45] MODELLING DESIGN REQUIREMENTS OF A FLOOR PLAN.
    Montanana, Antoni
    Llinares, Carmen
    Page, Alvaro F.
    OPEN HOUSE INTERNATIONAL, 2015, 40 (04) : 88 - 93
  • [46] An experimental study of condensation on an aluminum radiant ceiling panel surface with superhydrophobic treatment
    Zhong, Ziwen
    Niu, Jianlei
    Ma, Wei
    Yao, Shuhuai
    Yang, Meng
    Wang, Zuankai
    ENERGY AND BUILDINGS, 2021, 252
  • [47] Structural behaviour of ferrocement-brick composite floor slab panel
    Thanoon, Waleed A.
    Yardim, Yavuz
    Jaafar, M. S.
    Noorzaei, J.
    CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (11) : 2224 - 2230
  • [48] Preparing gypsum-based self-levelling energy storage mortar via fly ash cenospheres/paraffin used for floor radiant heating
    Wang, Fei
    Qiao, Zhigang
    Zheng, Wukui
    Li, Yuchen
    Gou, Yujin
    Qi, Yongle
    Li, Hui
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 423
  • [49] Design of panel heating and cooling systems
    Klan, H
    Bohle, J
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 566 - 573
  • [50] Phase change temperature adjustment of CH3COONa.3H2O to fabricate composite phase change material for radiant floor heating
    Fu, Wanwan
    Zhou, Wei
    Lv, Geyun
    Zhang, Rongtang
    Peng, Hao
    Fang, Tao
    Liu, Jiesheng
    Chen, Weicheng
    Fang, Yutang
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 42