Comparison of gross pathology inspection and 9.4 T magnetic resonance imaging in the evaluation of radiofrequency ablation lesions in the left ventricle of the swine heart

被引:0
|
作者
Odehnalova, Eva [1 ]
Valikova, Lucia [1 ]
Caluori, Guido [1 ,2 ,3 ,4 ]
Kulik, Tomas [1 ,5 ]
Rimalova, Veronika [6 ]
Jadczyk, Tomasz [1 ,7 ]
Drazanova, Eva [8 ]
Pavlova, Iveta [8 ]
Pesl, Martin [1 ,2 ,9 ]
Kubes, Vaclav [10 ]
Starek, Zdenek [1 ,5 ]
机构
[1] St Annes Univ Hosp Brno, Int Clin Res Ctr, Intervent Cardiac Electrophysiol Grp, Brno, Czech Republic
[2] CEITEC Masaryk Univ, Nanotechnol, Brno, Czech Republic
[3] Fdn Bordeaux Univ, Electrophysiol & Heart Modeling Inst, IHU LIRYC, Pessac, France
[4] Univ Bordeaux, Cardiothorac Res Ctr Bordeaux, INSERM, Pessac, France
[5] St Annes Univ Hosp Brno, Dept Internal Med Cardioangiol 1, Brno, Czech Republic
[6] St Annes Univ Hosp Brno, Int Clin Res Ctr, Biostat, Brno, Czech Republic
[7] Med Univ Silesia, Div Cardiol & Struct Heart Dis, Katowice, Poland
[8] Czech Acad Sci, Inst Sci Instruments, Brno, Czech Republic
[9] Masaryk Univ Brno, Fac Med, Dept Biol, Brno, Czech Republic
[10] Univ Hosp Brno, Dept Pathol, Brno, Czech Republic
关键词
evaluation of radiofrequency ablation lesions; comparison of methods; gross pathology inspection; high-resolution MRI evaluation; animal experiments; catheter ablation of arrhythmias; ex vivo MRI scanning; INTEROBSERVER-VARIABILITY; CATHETER ABLATION; MRI; SEGMENTATION; TEMPERATURE; ELECTRODE; MODEL;
D O I
10.3389/fphys.2022.834328
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Aims: Gross pathology inspection (patho) is the gold standard for the morphological evaluation of focal myocardial pathology. Examination with 9.4 T magnetic resonance imaging (MRI) is a new method for very accurate display of myocardial pathology. The aim of this study was to demonstrate that lesions can be measured on high-resolution MRI images with the same accuracy as on pathological sections and compare these two methods for the evaluation of radiofrequency (RF) ablation lesion dimensions in swine heart tissue during animal experiment. Methods: Ten pigs underwent radiofrequency ablations in the left ventricle during animal experiment. After animal euthanasia, hearts were explanted, flushed with ice-cold cardioplegic solution to relax the whole myocardium, fixed in 10% formaldehyde and scanned with a 9.4 T magnetic resonance system. Anatomical images were processed using ImageJ software. Subsequently, the hearts were sliced, slices were photographed and measured in ImageJ software. Different dimensions and volumes were compared. Results: The results of both methods were statistically compared. Depth by MRI was 8.771 +/- 2.595 mm and by patho 9.008 & PLUSMN; 2.823 mm; p = 0.198. Width was 10.802 +/- 2.724 mm by MRI and 11.125 +/- 2.801 mm by patho; p = 0.049. Estuary was 2.006 +/- 0.867 mm by MRI and 2.001 +/- 0.872 mm by patho; p = 0.953. The depth at the maximum diameter was 4.734 +/- 1.532 mm on MRI and 4.783 +/- 1.648 mm from the patho; p = 0.858. The volumes of the lesions calculated using a formula were 315.973 +/- 257.673 mm(3) for MRI and 355.726 +/- 255.860 mm(3) for patho; p = 0.104. Volume directly measured from MRI with the "point-by-point " method was 671.702 +/- 362.299 mm(3). Conclusion: Measurements obtained from gross pathology inspection and MRI are fully comparable. The advantage of MRI is that it is a non-destructive method enabling repeated measurements in all possible anatomical projections.
引用
收藏
页数:13
相关论文
共 47 条
  • [41] Polycystic Kidney Disease Evaluation by Magnetic Resonance Imaging in Ischemia-Reperfusion Injured PKD1 Knockout Mouse Model Comparison of T2-Weighted FSE and True-FISP
    Zhou, Xiangzhi
    Bao, Haihua
    Takakura, Ayumi
    Zhou, Jing
    Albert, Mitchell
    Sun, Yanping
    INVESTIGATIVE RADIOLOGY, 2010, 45 (01) : 24 - 28
  • [42] Assessment of global and regional left ventricular function with a 16-slice spiral-CT using two different software tools for quantitative functional analysis and qualitative evaluation of wall motion changes in comparison with magnetic resonance imaging
    Koch, K
    Oellig, O
    Kunz, P
    Bender, P
    Oberholzer, K
    Mildenberger, P
    Hake, U
    Kreitner, KF
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12): : 1786 - 1793
  • [43] EVALUATION OF THE EXTENT OF MESORECTAL INVASION AND MESORECTAL FASCIA INVOLVEMENT IN PATIENTS WITH T3 RECTAL CANCER WITH 2-D AND 3-D TRANSRECTAL ULTRASOUND: A PILOT COMPARISON STUDY WITH MAGNETIC RESONANCE IMAGING FINDINGS
    Liu, Min
    Yin, ShaoHan
    Li, Qing
    Liu, Ying
    Pei, XiaoQing
    Han, Feng
    Li, An-Hua
    Zhou, JianHua
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (11) : 3008 - 3016
  • [44] Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences
    Inoue, Katsuhiro
    Maeda, Masayuki
    Umino, Maki
    Takase, Shinichi
    Yamahata, Tsunehiro
    Sakuma, Hajime
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 1035 - 1039
  • [45] Evaluation of diffusion-weighted magnetic resonance imaging of the rectal cancers: comparison between modified reduced field-of-view single-shot echo-planar imaging with tilted two-dimensional radiofrequency excitation pulses and conventional full field-of-view readout-segmented echo-planar imaging
    Inoue, Atsuo
    Tanabe, Masahiro
    Ihara, Kenichiro
    Hideura, Keiko
    Higashi, Mayumi
    Benkert, Thomas
    Imai, Hiroshi
    Yamane, Masatoshi
    Yamaguchi, Takahiro
    Ueda, Takaaki
    Ito, Katsuyoshi
    RADIOLOGIA MEDICA, 2023, 128 (10): : 1192 - 1198
  • [46] Comparison of multi-phase contrast-enhanced T1-weighted volumetric interpolated breath-hold examination and fat-suppressed T2-weighted combined with diffusion-weighted magnetic resonance imaging in anal fistula evaluation
    Tao, Qinglin
    Tang, Yibing
    Luo, Yongchao
    Li, Dade
    Lu, Renai
    Zheng, Zhiming
    Chen, Ming
    Li, Deli
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 8629 - 8643
  • [47] Dual-source parallel radiofrequency excitation ACR phantom magnetic resonance imaging at 3 T: Assessment of the effect of image quality on high-contrast spatial resolution, percent signal ghosting, and low-contrast object detectability in comparison with conventional single-source transmission
    Lee, Kyung-Bae
    Park, Yong-Sung
    Choe, Bo-Young
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (08) : 1630 - 1636