Legionella pneumophila: From potable water to treated greywater; quantification and removal during treatment

被引:46
作者
Blanky, Marina [1 ]
Rodriguez-Martinez, Sara [2 ]
Halpern, Malka [2 ,3 ]
Friedler, Eran [1 ]
机构
[1] Technion Israel Inst Technol, Fac Civil & Environm Engn, Haifa, Israel
[2] Univ Haifa, Dept Evolutionary & Environm Biol, Fac Nat Sci, IL-31999 Haifa, Israel
[3] Univ Haifa, Fac Nat Sci, Dept Biol & Environm, Oranim, Tivon, Israel
关键词
Greywater; Legionella; Removal efficiency; Treatment; TOC; Chlorination; DOMESTIC GREYWATER; DRINKING-WATER; HOT; REUSE; RECOVERY; QUALITY; SYSTEMS; AMEBAS;
D O I
10.1016/j.scitotenv.2015.06.121
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Greywater is an alternative water source that can help alleviate stress on depleted water resources. The main options for greywater reuse are toilet flushing and garden irrigation, both producing aerosols. For that reason transmission of inhalable pathogens like Legionella present a potential risk. To improve the understanding about Legionella in greywater, we traced the pathogen seasonally from the potable water system to the final steps of the greywater treatment in four houses in northern Israel. Physicochemical and microbiological parameters were analyzed in order to assess background greywater quality and to establish possible associations with Legionella. The mean concentrations of Legionella pneumophila isolated from the potable water system were 6.4 x 10(2) and 5.9 x 10(3) cfu/l in cold and hot water respectively. By amending the ISO protocol for Legionella isolation from drinking water, we succeeded in quantifying Legionella in greywater. The mean Legionella concentrations that were found in raw, treated and treated chlorinated greywater were 1.2 x 10(5), 2.4 x 10(4) and 5.7 x 10(3) cfu/l respectively. While Legionella counts in potable water presented a seasonal pattern with high concentrations in summer, its counts in greywater presented an almost inversed pattern. Greywater treatment resulted in 95% decrease in Legionella counts. No significant difference was found between Legionella concentrations in potable water and the treated chlorinated greywater. These findings indicate that regarding Legionella, reusing treated chlorinated greywater would exhibit a risk that is very similar to the risk associated with using potable water for the same non-potable uses. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:557 / 565
页数:9
相关论文
共 60 条
[1]  
[Anonymous], 2006, Guidelines for the Safe Use of Wastewater, Excreta and Greywater: Policy and regulatory aspects, V1
[2]  
[Anonymous], 2004, GUID WAT REUS
[3]  
[Anonymous], 1999, ISO 6222:1999
[4]  
[Anonymous], 2006, STANDARD METHODS EXA, DOI DOI 10.5860/CHOICE.37-2792
[5]  
[Anonymous], 2012, 566732012 ISO
[6]  
Arvand M, 2011, EUROSURVEILLANCE, V16, P9
[7]  
Bartie C, 2001, WATER SA, V27, P523
[8]   The question of pathogen quantification in disinfected graywater [J].
Benami, Maya ;
Gillor, Osnat ;
Gross, Amit .
SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 506 :496-504
[9]   Assessment of pathogenic bacteria in treated graywater and irrigated soils [J].
Benami, Maya ;
Gross, Amit ;
Herzberg, Moshe ;
Orlofsky, Ezra ;
Vonshak, Ahuva ;
Gillor, Osnat .
SCIENCE OF THE TOTAL ENVIRONMENT, 2013, 458 :298-302
[10]  
BERCOVIER H, 1986, ISRAEL J MED SCI, V22, P644