Predictors of high endotoxin concentrations in the settled dust of German homes

被引:79
作者
Bischof, W
Koch, A
Gehring, U
Fahlbusch, B
Wichmann, HE
Heinrich, J
机构
[1] Univ Jena, Dept Indoor Climatol, ARK, D-99096 Erfurt, Germany
[2] Univ Jena, Inst Clin Immunol, D-6900 Jena, Germany
[3] GSF Munich, Inst Epidemiol, Munich, Germany
关键词
endotoxin; dust; residential; risk assessment; biological contamination; building hygiene;
D O I
10.1034/j.1600-0668.2002.120102.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Endotoxin concentrations in settled house dust were measured within the collaborative study named INGA (Indoor Exposure and Genetics in Asthma) together with other asthma-related indoor factors in 405 randomly selected homes in two German cities. Endotoxin was assayed using the quantitative kinetic chromogenic Limulus Amebocyte Lysate (LAL) method. The mean concentration of 2,274 ng endotoxin/g dust in living rooms is about two orders of magnitude below mean occupational exposure (e.g. agriculture). Endotoxin concentrations are higher in old buildings (means ratio=(MR) 1.52,95% C.I.: 1.14; 2.04), and in the lower storey of the dwelling (MR=1.30, 95% C.I.: 1.04; 1.62). Furthermore, higher endotoxin concentrations are associated with longer occupancy in the apartment (MR=1.63, 95% C.I.: 1.21; 2.18), high utilisation of the apartment during the sampling period (MR=2.52, 95% C.I.: 1.42; 4.47), infrequent vacuum cleaning of the carpets (MR=1.67; 95% C.I.: 1.10; 2.54), an indifferent attitude to ventilation (MR=1.37; 95% C.I.: 1.03; 1.82), keeping cats (MR=1.91; 95% C.I.: 1.43; 2.55) and dogs (1.57; 95% C.I.: 1.08; 2.30), as well as the occurrence of mice (MR=1.39; 95% C.I.: 1.00; 1.93). The season and indoor climate (operative temperature and relative humidity) did not effect endotoxin concentration. These results indicate that high endotoxin concentration in settled dust is an indicator of poor hygienic conditions in homes.
引用
收藏
页码:2 / 9
页数:8
相关论文
共 21 条
  • [1] BISCHOF W, 1995, ALLERGOLOGIE, V18, P506
  • [2] ASTHMATIC SYMPTOMS AND INDOOR LEVELS OF MICROORGANISMS AND HOUSE-DUST MITES
    BJORNSSON, E
    NORBACK, D
    JANSON, C
    WIDSTROM, J
    PALMGREN, U
    STROM, G
    BOMAN, G
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 1995, 25 (05) : 423 - 431
  • [3] Braun-Fahrländer C, 1999, CLIN EXP ALLERGY, V29, P28, DOI 10.1046/j.1365-2222.1999.00479.x
  • [4] Endotoxin and β(1→3)-glucan in house dust and the relation with home characteristics:: A pilot study in 25 German houses
    Douwes, J
    Doekes, G
    Heinrich, J
    Koch, A
    Bischof, W
    Brunekreef, B
    [J]. INDOOR AIR, 1998, 8 (04) : 255 - 263
  • [5] DOUWES J, 1998, THESIS AGR U WAGENIN
  • [6] Relation between house-dust endotoxin exposure, type 1 T cell development, and allergen sensitisation in infants at high risk of asthma
    Gereda, JE
    Leung, DYM
    Thatayatikom, A
    Streib, JE
    Price, MR
    Klinnert, MD
    Liu, AH
    [J]. LANCET, 2000, 355 (9216) : 1680 - 1683
  • [7] Gross I, 2000, CLIN EXP ALLERGY, V30, P376, DOI 10.1046/j.1365-2222.2000.00780.x
  • [8] Characterization and variability of endotoxin and 3-hydroxy fatty acids in an office building during a particle intervention study
    Hines, CJ
    Milton, DK
    Larsson, L
    Petersen, MR
    Fisk, WJ
    Mendell, MJ
    [J]. INDOOR AIR, 2000, 10 (01) : 2 - 12
  • [9] Indoor viable mold spores - a comparison between two cities, Erfurt (eastern Germany) and Hamburg (western Germany)
    Koch, A
    Heilemann, KJ
    Bischof, W
    Heinrich, J
    Wichmann, HE
    [J]. ALLERGY, 2000, 55 (02) : 176 - 180
  • [10] Martinez FD, 1999, LANCET, V354, pS12, DOI 10.1016/S0140-6736(99)90437-3