Simultaneous Determination of Trace Amounts of Cobalt and Nickel in Water and Food Samples Using a Combination of Partial Least Squares Method and Dispersive Liquid-Liquid Microextraction Based on Ionic Liquid

被引:42
作者
Khani, Rouhollah [1 ]
Shemirani, Farzaneh [1 ]
机构
[1] Univ Tehran, Univ Coll Sci, Sch Chem, Tehran, Iran
关键词
Trace metals; Food samples; Partial least squares; Simultaneous determination; Ionic liquid; Dispersive liquid-liquid microextraction; SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION; AMBERLITE XAD-16; HEAVY-METALS; ENVIRONMENTAL-SAMPLES; PRECONCENTRATION; SEDIMENT; COLUMN; IRON;
D O I
10.1007/s12161-012-9449-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A new, sensitive, and simple combined method including ionic liquid (IL)-based dispersive liquid-liquid microextraction and partial least squares method (PLS) was developed for simultaneous preconcentration and determination of cobalt and nickel in water and food samples. In this work, a small amount of an IL 1-hexyl-3-methylimmidazolium bis (trifluormethylsulfonyl)imid ([Hmim][Tf2N]) as an extraction solvent was dissolved in ethanol as a disperser solvent and then the binary solution was rapidly injected by a syringe into the water sample containing Co2+ and Ni2+, which were complexed by 1-(2-pyridylazo)-2-naphthol. After preconcentration, the absorbance of the extracted ions was measured in the wavelength range of 200-700 nm. The partial least squares method was then applied for simultaneous determination of each individual ion. The parameters controlling the behavior of the system were investigated and optimum conditions were selected. Eleven binary mixtures of cobalt and nickel were selected as the calibration set. The calibration models were validated with four synthetic mixtures containing the metal ions in different proportions, which were randomly designed. The best calibration model was obtained by using PLS-1 regression. Calibration graphs were linear in the range of 2.0-20.0 and 2.0-15.0 ng mL(-1) with a limit of detection of 0.65 and 0.32 ng mL(-1) for cobalt and nickel, respectively. The root mean square errors of prediction for cobalt and nickel were 0.4032 and 0.2980, respectively. Satisfactory results were reported for simultaneous determination of trace levels of cobalt and nickel in water, food, and geological certified reference material samples.
引用
收藏
页码:386 / 394
页数:9
相关论文
共 44 条
[1]   Fractionation of heavy metals in sediment by using microwave assisted sequential extraction procedure and determination by inductively coupled plasma mass spectrometry [J].
Alonso Castillo, M. L. ;
Vereda Alonso, E. ;
Siles Cordero, M. T. ;
Cano Pavon, J. M. ;
Garcia de Torres, A. .
MICROCHEMICAL JOURNAL, 2011, 98 (02) :234-239
[2]  
Ankel-Fuchs D, 1988, NICKEL ESSENTIAL TRA, P93
[3]   Determination of thallium traces by ETAAS after on-line matrix separation and preconcentration in a flow injection system [J].
Asadoulahi, Taherah ;
Dadfarnia, Shayessteh ;
Shabani, Ali Mohammad Haji .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2007, 18 (07) :1353-1359
[4]  
Babior BM, 1975, COBLAMIN BIOCH PATHO
[5]   Optimization of cloud point extraction and solid phase extraction methods for speciation of arsenic in natural water using multivariate technique [J].
Baig, Jameel A. ;
Kazi, Tasneem G. ;
Shah, Abdul Q. ;
Arain, Mohammad B. ;
Afridi, Hassan I. ;
Kandhro, Ghulam A. ;
Khan, Sumaira .
ANALYTICA CHIMICA ACTA, 2009, 651 (01) :57-63
[6]   A procedure for determination of cobalt in water samples after dispersive liquid-liquid microextraction [J].
Baliza, Patricia Xavier ;
Gomes Teixeira, Leonardo Sena ;
Lemos, Valfredo Azevedo .
MICROCHEMICAL JOURNAL, 2009, 93 (02) :220-224
[7]   BIOSYNTHESIS OF VITAMIN-B12 [J].
BATTERSBY, AR .
ACCOUNTS OF CHEMICAL RESEARCH, 1993, 26 (01) :15-21
[8]  
Baytak S, 2007, ACTA CHIM SLOV, V54, P385
[9]   A novel ionic liquid/micro-volume back extraction procedure combined with flame atomic absorption spectrometry for determination of trace nickel in samples of nutritional interest [J].
Dadfarnia, Shayesteh ;
Shabani, Ali Mohammad Haji ;
Bidabadi, Mahboubeh Shirani ;
Jafari, Abbas Ali .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 173 (1-3) :534-538
[10]   Robust partial least squares model for prediction of green tea antioxidant capacity from chromatograms [J].
Daszykowski, M. ;
Heyden, Y. Vander ;
Walczak, B. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1176 (1-2) :12-18