Quantitative measurements on the human ascending aortic flow using 2D cine phase-contrast magnetic resonance imaging

被引:8
作者
Yokosawa, S
Nakamura, M
Wada, S
Isoda, H
Takeda, H
Yamaguchi, T
机构
[1] Tohoku Univ, Grad Sch Engn, Dept Bioengn & Robot, Sendai, Miyagi 9808579, Japan
[2] Hamamatsu Univ Sch Med, Dept Radiol, Hamamatsu, Shizuoka 4313192, Japan
关键词
measurement; biomechanics; image processing; cine phase contrast; magnetic resonance Imaging; blood flow; aorta; velocity profile;
D O I
10.1299/jsmec.48.459
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The flow in the human ascending aorta was quantified using two-dimensional (2D) cine phase-contrast magnetic resonance imaging (MRI). The quality and reliability of the method were demonstrated with a specially designed phantom model; the flow rate determined with the MRI agreed well with that obtained with a measuring cylinder. The method was then used to measure the aortic blood flow of three healthy human volunteers. The velocity profiles at the supra-aortic valvular plane and ascending aortic plane (approximately 2 and 5 cm distal to the aortic valve, respectively) were significantly different. At the peak of systole, the profile was almost axisymmetric at the supra-aortic valvular plane, while it was skewed towards the anterior side of the vessel at the ascending aorta. The Reynolds number, volume flow rate, and stroke volume were all within the normal physiological range. This study demonstrated that the 2D cine phase-contrast MRI technique can be used to provide detailed information on the flow velocity and configuration of a blood vessel, making it a promising tool for analyzing complex hemodynamics in the aorta.
引用
收藏
页码:459 / 467
页数:9
相关论文
共 29 条
[1]  
CARO CG, 1978, MECH CIRCULATION, P151
[2]   A three-dimensional computational analysis of fluid-structure interaction in the aortic valve [J].
De Hart, J ;
Peters, GWM ;
Schreurs, PJG ;
Baaijens, FPT .
JOURNAL OF BIOMECHANICS, 2003, 36 (01) :103-112
[3]   Noninvasive measurement of time-varying three-dimensional relative pressure fields within the human heart [J].
Ebbers, T ;
Wigström, L ;
Bolger, AF ;
Wranne, B ;
Karlsson, M .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (03) :288-293
[4]  
Fujioka H, 2000, CLINICAL APPLICATION OF COMPUTATIONAL MECHANICS TO THE CARDIOVASCULAR SYSTEM, P99
[5]   Magnetic resonance angiography [J].
Graves, MJ .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :6-28
[6]   Blood flow velocity profiles in the aortic annulus:: A 3-dimensional freehand color flow Doppler imaging study [J].
Haugen, BO ;
Berg, S ;
Brecke, KM ;
Torp, H ;
Slordahl, SA ;
Skjærpe, T ;
Samstad, SO .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (04) :328-333
[7]   Effects of wall motion and compliance on flow patterns in the ascending aorta [J].
Jin, S ;
Oshinski, J ;
Giddens, DP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (03) :347-354
[8]   Asymmetric redirection of flow through the heart [J].
Kilner, PJ ;
Yang, GZ ;
Wilkes, AJ ;
Mohiaddin, RH ;
Firmin, DN ;
Yacoub, MH .
NATURE, 2000, 404 (6779) :759-761
[9]   HELICAL AND RETROGRADE SECONDARY FLOW PATTERNS IN THE AORTIC-ARCH STUDIED BY 3-DIRECTIONAL MAGNETIC-RESONANCE VELOCITY MAPPING [J].
KILNER, PJ ;
YANG, GZ ;
MOHIADDIN, RH ;
FIRMIN, DN ;
LONGMORE, DB .
CIRCULATION, 1993, 88 (05) :2235-2247
[10]  
KLIPSTEIN RH, 1987, BRIT HEART J, V58, P316