High temperature reversed-phase HPLC using deuterium oxide as a mobile phase for the separation of model pharmaceuticals with multiple on-line spectroscopic analysis (UV, IR, 1H-NMR and MS)

被引:24
作者
Louden, D
Handley, A
Taylor, S
Sinclair, I
Lenz, E
Wilson, KD
机构
[1] AstraZeneca Pharmaceut, Macclesfield SK10 4TG, Cheshire, England
[2] LGC, Runcorn WA7 4QD, Cheshire, England
关键词
D O I
10.1039/b107648p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The reversed-phase chromatography of a number of model pharmaceuticals using deuterium oxide (D2O) as the mobile phase at elevated temperatures, including superheated conditions (greater than 100 degreesC), is described. Following elution the analytes were characterised on-line via a combination of diode array UV, H-1-NMR, FT-IR spectroscopy and mass spectrometry. This combination of spectrometers enabled the on-flow collection of full UV, H-1-NMR, IR and mass spectra for a range of compounds in amounts ranging from 46 to 500 mug on-column. The advantages of the use of D2O alone as mobile phase for chromatography with multiple spectroscopic characterisation of analytes is discussed.
引用
收藏
页码:1625 / 1629
页数:5
相关论文
共 20 条
[1]   ONLINE COUPLING OF SUPERCRITICAL-FLUID CHROMATOGRAPHY AND PROTON HIGH-FIELD NUCLEAR-MAGNETIC-RESONANCE SPECTROSCOPY [J].
ALBERT, K ;
BRAUMANN, U ;
TSENG, LH ;
NICHOLSON, G ;
BAYER, E ;
SPRAUL, M ;
HOFMANN, M ;
DOWLE, C ;
CHIPPENDALE, M .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3042-3046
[2]   Buffered superheated water as an fluent for reversed-phase high performance liquid chromatography [J].
Chienthavorn, O ;
Smith, RM .
CHROMATOGRAPHIA, 1999, 50 (7-8) :485-489
[3]  
Dear GJ, 1998, RAPID COMMUN MASS SP, V12, P2023, DOI 10.1002/(SICI)1097-0231(19981230)12:24<2023::AID-RCM431>3.0.CO
[4]  
2-6
[5]  
Holt RM, 1997, J MASS SPECTROM, V32, P64, DOI 10.1002/(SICI)1096-9888(199701)32:1<64::AID-JMS450>3.0.CO
[6]  
2-7
[7]  
LENZ E, 2001, IN PRESS J PHARM BIO
[8]   Reversed-phase high-performance liquid chromatography combined with on-line UV diode array, FT infrared, and 1H nuclear magnetic resonance spectroscopy and time-of-flight mass spectrometry:: Application to a mixture of nonsteroidal antiinflammatory drugs [J].
Louden, D ;
Handley, A ;
Taylor, S ;
Lenz, E ;
Miller, S ;
Wilson, ID ;
Sage, A .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3922-3926
[9]   Spectroscopic characterisation and identification of ecdysteroids using high-performance liquid chromatography combined with on-line UV-diode array, FT-infrared and 1H-nuclear magnetic resonance spectroscopy and time of flight mass spectrometry [J].
Louden, D ;
Handley, A ;
Taylor, S ;
Lenz, E ;
Miller, S ;
Wilson, ID ;
Sage, A ;
Lafont, R .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (02) :237-246
[10]  
LOUDEN D, UNPUB ANAL CHEM