Comparison between three-dimensional speckle-tracking echocardiography and cardiac magnetic resonance imaging for quantification of left ventricular volumes and function

被引:95
作者
Kleijn, Sebastiaan A. [1 ,2 ]
Brouwer, Wessel P. [1 ,2 ]
Aly, Mohamed F. A. [1 ]
Russel, Iris K. [3 ]
de Roest, Gerben J. [1 ]
Beek, Aernout M. [1 ]
van Rossum, Albert C. [1 ,2 ]
Kamp, Otto [1 ,2 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Inst Cardiovasc Res ICaR VU, Dept Cardiol 5F 003, NL-1081 HV Amsterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Hagaziekenhuis, Dept Clin Phys, The Hague, Netherlands
关键词
Three-dimensional echocardiography; Speckle tracking; Cardiac magnetic resonance imaging; Left ventricular function; MYOCARDIAL STRAIN-MEASUREMENT; MRI; WALL; REPRODUCIBILITY; SONOMICROMETRY; VALIDATION;
D O I
10.1093/ehjci/jes030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the accuracy of three-dimensional speckle-tracking echocardiography (3DSTE) to evaluate left ventricular (LV) volumes, ejection fraction (EF), and global circumferential strain (CS) in comparison with cardiac magnetic resonance imaging (MRI) in a healthy population. A total of 45 out of 50 consecutive healthy subjects (38 males, age 45 15 years) successfully underwent both 3DSTE and MRI on the same day. Three-dimensional echocardiography data sets were analysed using speckle tracking to measure LV end-diastolic and end-systolic volumes, EF, and global CS. With MRI, the method of discs approximation was used to obtain volumes and the EF, whereas CS was acquired using myocardial tissue tagging. Inter-technique comparisons included regression and the BlandAltman analysis. For quantification of LV volumes, 3DSTE correlated well with MRI (r: 0.750.81), but volumes were significantly underestimated with relatively large biases (1334 mL) and wide limits of agreement (SD: 1125 mL). However, excellent accuracy was revealed for measurement of EF by 3DSTE with a good correlation (r: 0.91), minimal bias, and narrow limits of agreement (0.6 1.7) compared with MRI. For measurement of CS, a large mean bias was found between techniques (10.0), despite narrow limits of agreement (SD: 1.7) and a good correlation between techniques (r: 0.80). Although 3DSTE-derived LV volumes are underestimated in most patients compared with MRI, measurement of the LVEF revealed excellent accuracy. Measurements of CS were systematically greater (i.e. more negative) with 3DSTE than MRI, which likely reflects various inter-technique differences that preclude direct comparability of their measurements.
引用
收藏
页码:834 / 839
页数:6
相关论文
共 26 条
  • [1] Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    Alfakih, K
    Plein, S
    Thiele, H
    Jones, T
    Ridgway, JP
    Sivananthan, MU
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) : 323 - 329
  • [2] Noninvasive myocardial strain measurement by speckle tracking echocardiography - Validation against sonomicrometry and tagged magnetic resonance imaging
    Amundsen, BH
    Helle-Valle, T
    Edvardsen, T
    Torp, H
    Crosby, J
    Lyseggen, E
    Stoylen, A
    Ihlen, H
    Lima, JAC
    Smiseth, OA
    Slordahl, SA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 789 - 793
  • [3] Regional myocardial long-axis strain and strain rate measured by different tissue Doppler and speckle tracking echocardiography methods: a comparison with tagged magnetic resonance imaging
    Amundsen, Brage H.
    Crosby, Jonas
    Steen, Per Arvid
    Torp, Hans
    Slordahl, Stig A.
    Stoylen, Asbjorn
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (02): : 229 - 237
  • [4] Quantitative assessment of regional myocardial function with MR-tagging in a multi-center study: interobserver and intraobserver agreement of fast strain analysis with Harmonic Phase (HARP) MRI
    Castillo, E
    Osman, NF
    Rosen, BD
    El-Shehaby, I
    Pan, L
    Jerosch-Herold, M
    Lai, SH
    Bluemke, DA
    Lima, JAC
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (05) : 783 - 791
  • [5] Reproducibility and Inter-Vendor Variability of Left Ventricular Deformation Measurements by Three-Dimensional Speckle-Tracking Echocardiography
    Gayat, Etienne
    Ahmad, Homaa
    Weinert, Lynn
    Lang, Roberto M.
    Mor-Avi, Victor
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (08) : 878 - 885
  • [6] How do hypertrophic cardiomyopathy mutations affect myocardial function in carriers with normal wall thickness? Assessment with cardiovascular magnetic resonance
    Germans, Tjeerd
    Russel, Iris K.
    Gotte, Marco J. W.
    Spreeuwenberg, Marieke D.
    Doevendans, Pieter A.
    Pinto, Yigal M.
    van der Geest, Rob J.
    van der Velden, Jolanda
    Wilde, Arthur A. M.
    van Rossum, Albert C.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12
  • [7] Assessment of Myocardial Mechanics Using Speckle Tracking Echocardiography: Fundamentals and Clinical Applications
    Geyer, Holly
    Caracciolo, Giuseppe
    Abe, Haruhiko
    Wilansky, Susan
    Carerj, Scipione
    Gentile, Federico
    Nesser, Hans-Joachim
    Khandheria, Bijoy
    Narula, Jagat
    Sengupta, Partho P.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (04) : 351 - 369
  • [8] Assessment of subendocardial vs. subepicardial left ventricular rotation and twist using two-dimensional speckle tracking echocardiography: comparison with tagged cardiac magnetic resonance
    Goffinet, Celine
    Chenot, Fabien
    Robert, Annie
    Pouleur, Anne-Catherine
    de Waroux, Jean-Benoit le Polain
    Vancrayenest, David
    Gerard, Olivier
    Pasquet, Agnes
    Gerber, Bernhard L.
    Vanoverschelde, Jean-Louis
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 (05) : 608 - 617
  • [9] Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy
    Grothues, F
    Smith, GC
    Moon, JCC
    Bellenger, NG
    Collins, P
    Klein, HU
    Pennell, DJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (01) : 29 - 34
  • [10] Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography
    Jenkins, C
    Bricknell, K
    Hanekom, L
    Marwick, TH
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (04) : 878 - 886