Assessments of the physical performance of 2 generations of 2 direct digital intraoral sensors

被引:14
作者
Attaelmanan, AG [1 ]
Borg, E [1 ]
Gröndahl, HG [1 ]
机构
[1] Univ Gothenburg, Dept Oral Diagnost Radiol, Fac Odontol, SE-40530 Gothenburg, Sweden
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 1999年 / 88卷 / 04期
关键词
D O I
10.1016/S1079-2104(99)70073-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To evaluate the performance of 4 intraoral direct digital sensors regarding their fundamental physical characteristics. The sensors are made by Schick Technologies Inc (Long Island City, NY) and Gender Dental Systems (Milan, Italy). Study design. The sensors were exposed by using a Prostyle dental x-ray machine (Planmeca Oy, Helsinki, Finland) operating at 50 kV, 8 mA and various exposure times. Three test phantoms were used: a homogeneous 10-mm thick aluminum block, an aluminum block with a pattern of holes of varying sizes, and a resolving power target. Digital images were transferred as 8 bit TIFF files and analyzed by using a personal computer. Results and conclusions. Some improvements could be observed in the physical performance of the new generation of direct digital radiographic sensors when compared with the earlier generation. Smaller pixels and higher quantum efficiency have improved sensor performance.
引用
收藏
页码:517 / 523
页数:7
相关论文
共 28 条
  • [1] On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems
    Borg, E
    Grondahl, HG
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (02) : 82 - 88
  • [2] Detection of small differences in mass using a direct digital dental X-ray system
    Chen, SK
    Hollender, L
    Omnell, KA
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1997, 26 (01) : 63 - 66
  • [3] DETECTOR RESPONSE AND EXPOSURE CONTROL OF THE RADIO VISIOGRAPHY SYSTEM (RVG 32000 ZHR)
    CHEN, SK
    HOLLENDER, L
    ODONT, D
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1993, 76 (01): : 104 - 111
  • [4] A PRACTICAL METHOD TO MEASURE THE MTF OF CT SCANNERS
    DROEGE, RT
    MORIN, RL
    [J]. MEDICAL PHYSICS, 1982, 9 (05) : 758 - 759
  • [5] A PRACTICAL METHOD TO ROUTINELY MONITOR RESOLUTION IN DIGITAL IMAGES
    DROEGE, RT
    [J]. MEDICAL PHYSICS, 1983, 10 (03) : 337 - 343
  • [6] Farman A G, 1995, Quintessence Int, V26, P399
  • [7] FOSSUM ER, 1993, P SOC PHOTO-OPT INS, V1900, P2, DOI 10.1117/12.148585
  • [8] STATISTICAL CONTRAST ENHANCEMENT OF SUBFRACTION IMAGES FOR RADIOGRAPHIC CARIES DIAGNOSIS
    GRONDAHL, HG
    GRONDAHL, K
    OKANO, T
    WEBBER, RL
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1982, 53 (02): : 219 - 223
  • [9] SENS-A-RAY CHARACTERISTICS WITH VARIATIONS IN-BEAM QUALITY
    HARADA, T
    NISHIKAWA, K
    SHIBUYA, H
    HAYAKAWA, Y
    KUROYANAGI, K
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 80 (01): : 120 - 123
  • [10] Optimum exposure ranges for computed dental radiography
    Hayakawa, Y
    Farman, AG
    Scarfe, WC
    Kuroyanagi, K
    Rumack, PM
    Schick, DB
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (02) : 71 - 75