High efficiency and workflow of His bundle pacing and atrioventricular node ablation guided by three-dimensional mapping system

被引:5
作者
Sun, Yuanjun [1 ]
Yu, Xiaohong [1 ]
Xiao, Xianjie [1 ]
Yin, Xiaomeng [1 ]
Gao, Lianjun [1 ]
Zhang, Rongfeng [1 ]
Dai, Shiyu [1 ]
Wang, Nan [1 ]
Zhang, Duoduo [1 ]
Dong, Yingxue [1 ]
Yang, Yanzong [1 ]
Xia, Yunlong [1 ]
机构
[1] Dalian Med Univ, Dept Cardiol, Affiliated Hosp 1, Dalian, Liaoning, Peoples R China
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2020年 / 43卷 / 10期
关键词
atrial fibrillation; atrioventricular node ablation; His bundle pacing; three-dimensional mapping; PERMANENT PACEMAKER; CATHETER; LEAD;
D O I
10.1111/pace.14061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Atrioventricular node (AVN) ablation combined with His bundle pacing is an effective strategy for permanent atrial fibrillation (AF) with rapid ventricular rate refractory to pharmacological therapy. We aimed to access the feasibility and efficiency of His bundle pacing and AVN ablation guided by three-dimensional (3-D) mapping system throughout the procedure. Methods Eighteen patients with permanent AF with refractory rate and symptoms were referred for His bundle pacing and AVN ablation guided by 3-D mapping (CARTO3). Electroanatomic 3-D mapping of the right atrium and right ventricle was performed by the ablation catheter with CARTO 3 system, followed by the visualization of the leads for implantation and AVN ablation. Results Implantation of His bundle and ventricular leads and AVN ablation were achieved successfully with the help of 3-D mapping in 17 patients. Selective His bundle pacing was achieved in five patients (29.4%), and the other (70.6%) were nonselective His bundle pacing. The mean procedure duration was 99.4 +/- 16.4 minutes. The mean fluoroscopy time was 7.0 +/- 2.6 minutes. The time spent on His lead implantation was 6.1 +/- 3.2 minutes. One patient experienced AVN ablation from left side under aortic valves due to no effect of ablation in right atrium. Conclusion His bundle pacing and AVN ablation guided by throughout real-time 3-D mapping system are of high-efficiency and feasibility.
引用
收藏
页码:1165 / 1172
页数:8
相关论文
共 19 条
  • [1] The Efficacy of His Bundle Pacing: Lessons Learned From Implementation for the First Time at an Experienced Electrophysiology Center
    Bhatt, Advay G.
    Musat, Dan L.
    Milstein, Nicolle
    Pimienta, Jacqueline
    Flynn, Laura
    Sichrovsky, Tina
    Preminger, Mark W.
    Mittal, Suneet
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (11) : 1397 - 1406
  • [2] "Near-zero" fluoroscopic exposure in supraventricular arrhythmia ablation using the EnSite NavX™ mapping system: personal experience and review of the literature
    Casella, Michela
    Pelargonio, Gemma
    Dello Russo, Antonio
    Riva, Stefania
    Bartoletti, Stefano
    Santangeli, Pasquale
    Scara, Antonio
    Sanna, Tommaso
    Proietti, Riccardo
    Di Biase, Luigi
    Gallinghouse, G. Joseph
    Narducci, Maria Lucia
    Sisto, Luigi
    Bellocci, Fulvio
    Natale, Andrea
    Tondo, Claudio
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2011, 31 (02) : 109 - 118
  • [3] 3-Dimensional Electroanatomic Mapping Guided Selective His Bundle Pacing
    Cay, Serkan
    Ozcan, Firat
    Ozeke, Ozcan
    Aras, Dursun
    Topaloglu, Serkan
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (03) : 415 - 417
  • [4] Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: Implant safety and electrical performance
    Gammage, Michael D.
    Lieberman, Randy A.
    Yee, Raymond
    Manolis, Antonis S.
    Compton, Steven J.
    Khazen, Cesar
    Schaaf, Katie
    Oleson, Kimberly A.
    Crossley, George H.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (08): : 858 - 865
  • [5] Benefits of Permanent His Bundle Pacing Combined With Atrioventricular Node Ablation in Atrial Fibrillation Patients With Heart Failure With Both Preserved and Reduced Left Ventricular Ejection Fraction
    Huang, Weijian
    Su, Lan
    Wu, Shengjie
    Xu, Lei
    Xiao, Fangyi
    Zhou, Xiaohong
    Ellenbogen, Kenneth A.
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (04):
  • [6] His bundle pacing, learning curve, procedure characteristics, safety, and feasibility: Insights from a large international observational study
    Keene, Daniel
    Arnold, Ahran D.
    Jastrzebski, Marek
    Burri, Haran
    Zweibel, Steven
    Crespo, Eric
    Chandrasekaran, Badrinathan
    Bassi, Sukhbinder
    Joghetaei, Nader
    Swift, Matthew
    Moskal, Pawel
    Francis, Darrel P.
    Foley, Paul
    Shun-Shin, Matthew J.
    Whinnett, Zachary I.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (10) : 1984 - 1993
  • [7] Radiation exposure during catheter ablation of atrial fibrillation
    Lickfett, L
    Mahesh, M
    Vasamreddy, C
    Bradley, D
    Jayam, V
    Eldadah, Z
    Dickfeld, T
    Kearney, D
    Dalal, D
    Lüderitz, B
    Berger, R
    Calkins, H
    [J]. CIRCULATION, 2004, 110 (19) : 3003 - 3010
  • [8] Ablate and pace strategy for atrial fibrillationo: long-term outcome of AIRCRAFT trial
    Lim, Kang-Teng
    Davis, Michael J. E.
    Powell, Anne
    Arnolda, Leonard
    Moulden, Kath
    Bulsara, Max
    Weerasooriya, Rukshen
    [J]. EUROPACE, 2007, 9 (07): : 498 - 505
  • [9] Safety and efficacy of catheter ablation in atrial fibrillation patients with left ventricular dysfunction
    Long, Songbing
    Xi, Yutao
    Gao, Lianjun
    Chen, Qi
    Cheng, Jie
    Yang, Yanzong
    Xia, Yunlong
    Yin, Xiaomeng
    [J]. CLINICAL CARDIOLOGY, 2020, 43 (03) : 305 - 314
  • [10] Near Zero Fluoroscopic Implantation of BIV ICD Using Electro-anatomical Mapping
    Mina, Adel
    Warnecke, Nicholas
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (11): : 1409 - 1416