Efficacy and Safety of the Woven EndoBridge (WEB) Device for the Treatment of Intracranial Aneurysms: A Systematic Review and Meta-Analysis

被引:102
作者
Asnafi, S. [1 ]
Rouchaud, A. [1 ]
Pierot, L. [3 ]
Brinjikji, W. [1 ]
Murad, M. H. [2 ]
Kallmes, D. F. [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Ctr Sci Healthcare Delivery, Rochester, MN USA
[3] Univ Reims, Maison Blanche Hosp, Dept Neuroradiol, Reims, France
关键词
PIPELINE EMBOLIZATION DEVICE; INTRASACCULAR FLOW-DISRUPTION; ENDOVASCULAR TREATMENT; REMODELING TECHNIQUE; CEREBRAL ANEURYSMS; FOLLOW-UP; EXPERIENCE; RECONSTRUCTION; THERAPY; ARTERY;
D O I
10.3174/ajnr.A4900
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Intrasaccular flow diverters are increasingly being used in the treatment of wide-neck and bifurcation aneurysms. We performed a systematic review and meta-analysis of existing literature on the Woven EndoBridge device in the treatment of intracranial aneurysms. MATERIALS AND METHODS: A comprehensive literature search was performed through October 1, 2015. We extracted information on baseline aneurysm and patient characteristics. Outcomes studied included immediate and midterm (>3 month) angiographic outcomes (complete occlusion as well as adequate occlusion, defined as complete occlusion or neck remnant), aneurysm retreatment, intraoperative rupture, perioperative morbidity and mortality, thromboembolic complications, and treatment failure. Meta-analysis was performed by using the random-effects model. RESULTS: Fifteen uncontrolled series were included in this analysis, including 565 patients with 588 aneurysms, of which 127 were ruptured. Initial complete and adequate occlusion rates were 27% (95% CI, 15%-39%) and 59% (95% CI, 39%-78%), respectively. Midterm complete and adequate occlusion rates after a median of 7 months were 39% (95% CI, 26%-52%) and 85% (95% CI, 78%-91%), respectively. Perioperative morbidity and mortality rates were 4% (95% CI, 1%-8%) and 1% (95% CI, 0%-2%), respectively. Midterm adequate occlusion rates for ruptured aneurysms were 85% (95% CI, 67%-98%), compared with 84% (95% CI, 72%-94%) for unruptured aneurysms (P=.89). Patients with ruptured aneurysm had similar rates of perioperative morbidity to patients with unruptured aneurysm (2%; 95% CI, 0%-26% versus 2%; 95% CI, 0%-6%, respectively; P=.35). CONCLUSIONS: Early evidence derived from uncontrolled studies suggests that Woven EndoBridge treatment has a good safety profile and promising rates of adequate occlusion, especially given the complexity of aneurysms treated. Further prospective clinical trials are needed to confirm these results and better define the risks and benefits of use of the Woven EndoBridge device in treating wide-neck and wide-neck bifurcation aneurysms.
引用
收藏
页码:2287 / 2292
页数:6
相关论文
共 45 条
[1]   Endovascular treatment of bifurcation intracranial aneurysms with the WEB SL/SLS: 6-month clinical and angiographic results [J].
Ambrosi, Patricia Bozzetto ;
Gory, Benjamin ;
Sivan-Hoffmann, Rotem ;
Riva, Roberto ;
Signorelli, Francesco ;
Labeyrie, Paul-Emile ;
Eldesouky, Islam ;
Sadeh-Gonike, Udi ;
Armoiry, Xavier ;
Turjman, Francis .
INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (04) :462-469
[2]  
[Anonymous], AJNR AM J NEURO 0602
[3]   Endovascular Treatment of Intracranial Aneurysms with the WEB Device: A Systematic Review of Clinical Outcomes [J].
Armoiry, X. ;
Turjman, F. ;
Hartmann, D. J. ;
Sivan-Hoffmann, R. ;
Riva, R. ;
Labeyrie, P. E. ;
Aulagner, G. ;
Gory, B. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (05) :868-872
[4]   Meta-analysis of prevalence [J].
Barendregt, Jan J. ;
Doi, Suhail A. ;
Lee, Yong Yi ;
Norman, Rosana E. ;
Vos, Theo .
JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 2013, 67 (11) :974-978
[5]   Woven EndoBridge Intrasaccular Flow Disrupter for the Treatment of Ruptured and Unruptured Wide-Neck Cerebral Aneurysms: Report of 55 Cases [J].
Behme, D. ;
Berlis, A. ;
Weber, W. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (08) :1501-1506
[6]   Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: Strategies in stent deployment and midterm follow-up [J].
Biondi, Alessandra ;
Janardhan, Vallabh ;
Katz, Jeffrey M. ;
Salvaggio, Kimberly ;
Riina, Howard A. ;
Gobin, Y. Pierre .
NEUROSURGERY, 2007, 61 (03) :460-468
[7]   Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center [J].
Briganti, Francesco ;
Napoli, Manuela ;
Leone, Giuseppe ;
Marseglia, Mariano ;
Mariniello, Giuseppe ;
Caranci, Ferdinando ;
Tortora, Fabio ;
Maiuri, Francesco .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (09) :1683-1690
[8]   Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis [J].
Brinjikji, Waleed ;
Murad, Mohammad H. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2013, 44 (02) :442-447
[9]   Single-Layer WEBs: lntrasaccular Flow Disrupters for Aneurysm Treatment-Feasibility Results from a European Study [J].
Caroff, J. ;
Mihalea, C. ;
Klisch, J. ;
Strasilla, C. ;
Berlis, A. ;
Patankar, T. ;
Weber, W. ;
Behme, D. ;
Jacobsen, E. A. ;
Liebig, T. ;
Prothmann, S. ;
Cognard, C. ;
Finkenzeller, T. ;
Moret, J. ;
Spelle, L. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (10) :1942-1946
[10]   Woven Endobridge (WEB) Device for endovascular treatment of ruptured intracranial wide-neck aneurysms: a single-center experience [J].
Caroff, Jildaz ;
Mihalea, Cristian ;
Dargento, Francesco ;
Neki, Hiroaki ;
Ikka, Leon ;
Benachour, Nidhal ;
Moret, Jacques ;
Spelle, Laurent .
NEURORADIOLOGY, 2014, 56 (09) :755-761