An enhanced model for the design of Diffusion Absorption Refrigerators

被引:32
作者
Starace, Giuseppe [1 ]
De Pascalis, Lorenzo [1 ]
机构
[1] Univ Salento, Dept Engn Innovat, Lecce, Italy
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2013年 / 36卷 / 05期
关键词
Diffusion; Absorption; Refrigerator; Thermal pump; Microwave; Experimental; PERFORMANCE;
D O I
10.1016/j.ijrefrig.2013.02.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
A steady state description of the thermal pump driving the Diffusion Absorption Refrigerator was integrated in the model previously proposed by the same authors. The thermal pump allows the DAR cycle to be activated, moving the strong mixture and separating the refrigerant from the weak one. So, the design parameters play a primary role in the DAR cycle performance in terms of COP. The enhanced model results were validated on a prototype built coupling a domestic 750 W-magnetron on a small purposely modified commercial DAR to activate the thermal pump. A maximum mismatch of 2.32% in the weak mixture mass flow rate and lower than 5% in COP between the predicted and measured data were found. The microwaves activated thermal pump produced a distinct reduction in the starting transient time of the refrigerator and for this reason it can be proposed as a valid candidate to be used as a rapid cooler in small refrigeration applications. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1495 / 1503
页数:9
相关论文
共 21 条
  • [1] A SIMPLE 2-PHASE FRICTIONAL PRESSURE-DROP CALCULATION METHOD
    BEATTIE, DRH
    WHALLEY, PB
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1982, 8 (01) : 83 - 87
  • [2] Performance enhancement of a diffusion-absorption refrigerator
    Chen, J
    Kim, JK
    Herold, KE
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1996, 19 (03): : 208 - 218
  • [3] Chexal B., 1992, Progress in Nuclear Energy, V27, P255, DOI 10.1016/0149-1970(92)90007-P
  • [4] Chexal B., 1997, Void fraction technology for design and analysis Tech. rep
  • [5] Chisholm D., 1983, Two-phase flow in pipelines and heat exchangers
  • [6] A slug-churn flow model for small-diameter airlift pumps
    deCachard, F
    Delhaye, JM
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1996, 22 (04) : 627 - 649
  • [7] Delano A., 1998, THESIS GEORGIA I TEC
  • [8] Simulation and experimental investigation into diffusion absorption cooling machines for air-conditioning applications
    Jakob, U.
    Eicker, U.
    Schneider, D.
    Taki, A. H.
    Cook, M. J.
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (10) : 1138 - 1150
  • [9] M. Conde Engineering, 2006, THERM PROP NH3 H2O M
  • [10] Nicklin D.J., 1962, P S 2 PHAS FLOW I ME