The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections

被引:64
作者
Baxmann, M. [1 ,2 ]
Jauch, S. Y. [2 ]
Schilling, C. [1 ,3 ,4 ]
Bloemer, W. [1 ]
Grupp, T. M. [1 ,5 ]
Morlock, M. M. [2 ]
机构
[1] Aesculap AG, Res & Dev, D-78532 Tuttlingen, Germany
[2] TUHH Hamburg Univ Technol, Inst Biomech, Hamburg, Germany
[3] Charite, Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[4] Charite, Charite, Berlin Brandenburg Ctr Regenerat Therapies, D-13353 Berlin, Germany
[5] Univ Munich, Clin Orthopaed Surg, Munich, Germany
关键词
Modular hip; Stem-neck interface; Fretting; Titanium alloy; TOTAL HIP-ARTHROPLASTY; FEMORAL-NECK; CORROSION; WEAR; PROSTHESIS; TI-6AL-4V; FREQUENCY; FRACTURE; FAILURE; CREVICE;
D O I
10.1016/j.medengphy.2012.07.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Modularity of femoral stems and neck components has become a more frequently used tool for an optimized restoration of the hip joint center and improvement of patient biomechanics. The additional taper interface increases the risk of mechanical failure due to fretting and crevice corrosion. Several failures of titanium alloy neck adapters have been documented in case-reports. An experimental fretting device was developed in this study to systematically investigate the effect of micromotion and contact pressure on fretting damage in contact situations similar to taper interfaces of modular hip prostheses under cyclic loading representative of in vivo load conditions. As a first application, the fretting behavior of Ti-6Al-4V titanium alloy components was investigated. Micromotions were varied between 10 mu m and 50 mu m, maximum contact pressures between 400 and 860 N/mm(2). All modes of fretting damage were observed: Fretting wear was found for high micromotions in combination with low contact pressures. Fretting fatigue occurred with reduced movement or increased contact pressures. With small micromotions or high normal pressures, low fretting damage was observed. The developed device can be used to evaluate taper design (and especially contact geometry) as well as different materials prior to clinical use. (C) 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:676 / 683
页数:8
相关论文
共 47 条
  • [31] Duration and frequency of every day activities in total hip patients
    Morlock, M
    Schneider, E
    Bluhm, A
    Vollmer, M
    Bergmann, G
    Müller, V
    Honl, M
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (07) : 873 - 881
  • [32] MECHANISMS OF FRETTING FATIGUE
    MUTOH, Y
    [J]. JSME INTERNATIONAL JOURNAL SERIES A-MECHANICS AND MATERIAL ENGINEERING, 1995, 38 (04): : 405 - 415
  • [33] Nakazawa K., 1992, 1159 ASTM STP, V1159, P115
  • [34] Frequency effect in fretting wear of Co-28Cr-6Mo versus Ti-6Al-4V implant alloys
    Schaaff, P
    Dalmiglio, M
    Holzwarth, U
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 77B (01) : 79 - 88
  • [35] Toni A, 2001, HIP INT, V11, P1
  • [36] Sex Differences in Hip Morphology: Is Stem Modularity Effective for Total Hip Replacement?
    Traina, Francesco
    De Clerico, Manuela
    Biondi, Federico
    Pilla, Federico
    Tassinari, Enrico
    Toni, Aldo
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 121 - 128
  • [37] MIGRATION OF CORROSION PRODUCTS FROM MODULAR HIP PROSTHESES - PARTICLE MICROANALYSIS AND HISTOPATHOLOGICAL FINDINGS
    URBAN, RM
    JACOBS, JJ
    GILBERT, JL
    GALANTE, JO
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (09) : 1345 - 1359
  • [38] Viceconti M, 1997, J BIOMED MATER RES, V35, P207, DOI 10.1002/(SICI)1097-4636(199705)35:2<207::AID-JBM9>3.0.CO
  • [39] 2-R
  • [40] Viceconti M, 1996, J BIOMED MATER RES, V30, P181