The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections

被引:64
作者
Baxmann, M. [1 ,2 ]
Jauch, S. Y. [2 ]
Schilling, C. [1 ,3 ,4 ]
Bloemer, W. [1 ]
Grupp, T. M. [1 ,5 ]
Morlock, M. M. [2 ]
机构
[1] Aesculap AG, Res & Dev, D-78532 Tuttlingen, Germany
[2] TUHH Hamburg Univ Technol, Inst Biomech, Hamburg, Germany
[3] Charite, Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[4] Charite, Charite, Berlin Brandenburg Ctr Regenerat Therapies, D-13353 Berlin, Germany
[5] Univ Munich, Clin Orthopaed Surg, Munich, Germany
关键词
Modular hip; Stem-neck interface; Fretting; Titanium alloy; TOTAL HIP-ARTHROPLASTY; FEMORAL-NECK; CORROSION; WEAR; PROSTHESIS; TI-6AL-4V; FREQUENCY; FRACTURE; FAILURE; CREVICE;
D O I
10.1016/j.medengphy.2012.07.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Modularity of femoral stems and neck components has become a more frequently used tool for an optimized restoration of the hip joint center and improvement of patient biomechanics. The additional taper interface increases the risk of mechanical failure due to fretting and crevice corrosion. Several failures of titanium alloy neck adapters have been documented in case-reports. An experimental fretting device was developed in this study to systematically investigate the effect of micromotion and contact pressure on fretting damage in contact situations similar to taper interfaces of modular hip prostheses under cyclic loading representative of in vivo load conditions. As a first application, the fretting behavior of Ti-6Al-4V titanium alloy components was investigated. Micromotions were varied between 10 mu m and 50 mu m, maximum contact pressures between 400 and 860 N/mm(2). All modes of fretting damage were observed: Fretting wear was found for high micromotions in combination with low contact pressures. Fretting fatigue occurred with reduced movement or increased contact pressures. With small micromotions or high normal pressures, low fretting damage was observed. The developed device can be used to evaluate taper design (and especially contact geometry) as well as different materials prior to clinical use. (C) 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:676 / 683
页数:8
相关论文
共 47 条
  • [11] Cristofolini L., 2003, Acta of Bioengineering and Biomechanics, V5, P77
  • [12] The effect of surface treatments on the fretting behavior of Ti-6Al-4V alloy
    Dallmiglio, Matteo
    Schaaff, Petra
    Holzwarth, Uwe
    Chiesa, Roberto
    Rondelli, Gianni
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (02) : 407 - 416
  • [13] Environmental effect on fretting of metallic materials for orthopaedic implants
    Duisabeau, L
    Combrade, P
    Forest, B
    [J]. WEAR, 2004, 256 (7-8) : 805 - 816
  • [14] Simulation of fretting wear at orthopaedic implant interfaces
    Ebramzadeh, E
    Billi, F
    Sangiorgio, SN
    Mattes, S
    Schmoelz, W
    Dorr, L
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 357 - 363
  • [15] Quantification of fretting damage
    Fouvry, S
    Kapsa, P
    Vincent, L
    [J]. WEAR, 1996, 200 (1-2) : 186 - 205
  • [16] Fretting-corrosion of materials used as orthopaedic implants
    Geringer, J
    Forest, B
    Combrade, P
    [J]. WEAR, 2005, 259 : 943 - 951
  • [17] Fretting Crevice Corrosion of Stainless Steel Stem-CoCr Femoral Head Connections: Comparisons of Materials, Initial Moisture, and Offset Length
    Gilbert, Jeremy L.
    Mehta, Manav
    Pinder, Bryan
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (01) : 162 - 173
  • [18] IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING
    GILBERT, JL
    BUCKLEY, CA
    JACOBS, JJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12): : 1533 - 1544
  • [19] Greenwald AS, 2011, HIGH PERFORMANCE MOD
  • [20] Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material
    Grupp, Thomas M.
    Weik, Thomas
    Bloemer, Wilhelm
    Knaebel, Hanns-Peter
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2010, 11