A new press-fit stem concept to reduce the risk of end-of-stem pain at revision TKA: A pre-clinical study

被引:14
作者
Completo, A. [1 ]
Fonseca, F. [2 ]
Simoes, J. A. [1 ]
Ramos, A. [1 ]
Relvas, C. [1 ]
机构
[1] Univ Aveiro, Dept Mech Engn, P-3810193 Aveiro, Portugal
[2] Coimbra Univ Hosp, Dept Orthopaed, P-3000075 Coimbra, Portugal
关键词
Revision total knee arthroplasty; Experimental study; Intramedullary stem; Strain gauges; TOTAL KNEE ARTHROPLASTY; MODULAR COMPONENTS; DESIGN; CEMENT; MALALIGNMENT; PROSTHESIS; TIBIA; FEMUR;
D O I
10.1016/j.knee.2011.12.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Revision total knee arthroplasty presents numerous technical challenges, with lower patient outcomes compared with those obtained in primary surgery. Extended stems have been used in revision total knee arthroplasty to improve component alignment and fixation. Hybrid fixation with cemented tibial tray and press-fit stem has shown good results. One of the disadvantages of this technique is pain related to the presence of a cementless diaphyseal engaging stem, often designated as end-of-stem pain. Patients with this pain have reported a decrease in overall satisfaction, as well as demonstrate a lower clinical outcome score. Clinical findings suggest that stem material and design are important factors in the development of end-of-stem pain. Therefore, a question can be raised: can a novel press-fit stem concept minimize bone strain changes at the stem tip? The hypothesis here considered lies upon the fact, that if periosteal cortex strain changes are minimized at the stem tip comparatively to the intact situation, the risk of end-of-stem pain might be minimized. Scope: This pre-clinical study was accomplished using synthetic tibiae to experimentally predict the periosteal cortex strains at the proximal and stem tip regions, with a commercial press-fit stem and a new stem concept. Conclusions: The results demonstrated that the new stem concept has the ability to minimize strain changes induced by the stem tip at the distal periosteal cortex and consequently, at the periosteal layer of bone tissue, which is highly pain sensitive, probably contributing to the reduction of the risk of end-of-stem pain. Level of evidence: V (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:537 / 542
页数:6
相关论文
共 19 条
[1]  
ANDRIACCHI TP, 1994, ORTHOP CLIN N AM, V25, P395
[2]   The effect of stem design on end-of-stem pain in revision total knee arthroplasty [J].
Barrack, RL ;
Stanley, T ;
Burt, M ;
Hopkins, S .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :119-124
[3]  
Barrack RL, 1999, CLIN ORTHOP RELAT R, P216
[4]   The influence of different tibial stem designs in load sharing and stability at the cement-bone interface in revision TKA [J].
Completo, A. ;
Simoes, J. A. ;
Fonseca, F. ;
Oliveira, M. .
KNEE, 2008, 15 (03) :227-232
[5]   Strain shielding in proximal tibia of stemmed knee prosthesis: Experimental study [J].
Completo, A. ;
Fonseca, F. ;
Simoes, J. A. .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :560-566
[6]   Relationship of design features of stemmed tibial knee prosthesis with stress shielding and end-of-stem pain [J].
Completo, A. ;
Talaia, P. ;
Fonseca, F. ;
Simoes, J. A. .
MATERIALS & DESIGN, 2009, 30 (04) :1391-1397
[7]   Mechanical Evaluation of Large-Size Fourth-Generation Composite Femur and Tibia Models [J].
Gardner, Matthew P. ;
Chong, Alexander C. M. ;
Pollock, Anthony G. ;
Wooley, Paul H. .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) :613-620
[8]  
Glenn J.C., 2010, J ARTHROPLASTY, V25, P497
[9]   Revision total knee arthroplasty - Fixation with modular stems [J].
Gofton, WT ;
Tsigaras, H ;
Butler, RA ;
Patterson, JJ ;
Barrack, RL ;
Rorabeck, CH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :158-168
[10]   REVISION TOTAL KNEE ARTHROPLASTY WITH USE OF MODULAR COMPONENTS WITH STEMS INSERTED WITHOUT CEMENT [J].
HAAS, SB ;
INSALL, JN ;
MONTGOMERY, W ;
WINDSOR, RE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (11) :1700-1707