Comparisons of Reproducibility and Mean Values of Diffusion Tensor Imaging-Derived Indices between Unipolar and Bipolar Diffusion Pulse Sequences

被引:6
作者
Miao, Hsiao-Chien [1 ]
Wu, Ming-Ting [2 ]
Kao, E-Fong [1 ]
Chiu, Yu-Hsien [3 ]
Chou, Ming-Chung [1 ,3 ]
机构
[1] Kaohsiung Med Univ, Dept Med Imaging & Radiol Sci, Kaohsiung 80708, Taiwan
[2] Kaohsiung Vet Gen Hosp, Dept Radiol, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ, Dept Healthcare Adm & Med Informat, Dept Healthcare, Kaohsiung, Taiwan
关键词
Unipolar; bipolar; DTI; reproducibility; mean value; PRINCIPAL EIGENVECTOR MEASUREMENTS; EDDY-CURRENT ARTIFACTS; BRAIN WHITE-MATTER; FRACTIONAL ANISOTROPY; ECHO TIME; B-VALUE; TISSUES; IMAGES; 1.5T; MRI;
D O I
10.1111/jon.12231
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Eddy current distortion is an important issue that may influence the quantitative measurements of diffusion tensor imaging (DTI). The corrections of eddy current artifacts could be performed using bipolar diffusion gradients or unipolar gradients with affine registration. Whether the diffusion pulse sequence affects the quantification of DTI indices and the technique that produces more reliable DTI indices in terms of reproducibility both remain unclear. Therefore, the purpose of this study was to compare the reproducibility and mean values of DTI-derived indices between unipolar and bipolar diffusion pulse sequences based on actual human brain data. Five repeated datasets of unipolar and bipolar DTI were acquired from 10 healthy subjects at different echo times (TEs). The reproducibility and mean values of DTI indices were assessed by calculating the coefficient of variation and mean values of the 5 repeated measurements. The results revealed that the reproducibility and mean values of DTI indices were significantly affected by the pulse sequence. Unipolar DTI exhibited significantly higher reproducibility than bipolar DTI even at the same TE, and the mean values of DTI indices were significantly different between them. Therefore, we concluded that the reproducibility and mean values of DTI indices were significantly influenced by diffusion pulse sequences.
引用
收藏
页码:892 / 899
页数:8
相关论文
共 34 条
  • [11] Effects of signal-to-noise ratio on the accuracy and reproducibility, of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
    Farrell, Jonathan A. D.
    Landman, Bennett A.
    Jones, Craig K.
    Smith, Seth A.
    Prince, Jerry L.
    van Zijl, Peter C. M.
    Mori, Susumu
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) : 756 - 767
  • [12] Dependence of brain DTI maps of fractional anisotropy and mean diffusivity on the number of diffusion weighting directions
    Giannelli, Marco
    Cosottini, Mirco
    Michelassi, Maria Chiara
    Lazzarotti, Guido
    Belmonte, Gina
    Bartolozzi, Carlo
    Lazzeri, Mauro
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 176 - 190
  • [13] Aging in deep gray matter and white matter revealed by diffusional kurtosis imaging
    Gong, Nan-Jie
    Wong, Chun-Sing
    Chan, Chun-Chung
    Leung, Lam-Ming
    Chu, Yiu-Ching
    [J]. NEUROBIOLOGY OF AGING, 2014, 35 (10) : 2203 - 2216
  • [14] B-value dependence of DTI quantitation and sensitivity in detecting neural tissue changes
    Hui, Edward S.
    Cheung, Matthew M.
    Chan, Kevin C.
    Wu, Ed X.
    [J]. NEUROIMAGE, 2010, 49 (03) : 2366 - 2374
  • [15] A global optimisation method for robust affine registration of brain images
    Jenkinson, M
    Smith, S
    [J]. MEDICAL IMAGE ANALYSIS, 2001, 5 (02) : 143 - 156
  • [16] Landman BA, 2006, 14 INT SOC MAGN RES, P2987
  • [17] Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
    Landman, Bennett A.
    Farrell, Jonathan A. D.
    Jones, Craig K.
    Smith, Seth A.
    Prince, Jerry L.
    Mori, Susumu
    [J]. NEUROIMAGE, 2007, 36 (04) : 1123 - 1138
  • [18] The B-Matrix Must Be Rotated When Correcting for Subject Motion in DTI Data
    Leemans, Alexander
    Jones, Derek K.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1336 - 1349
  • [19] Melhem ER, 2000, AM J NEURORADIOL, V21, P1813
  • [20] Correcting Eddy Current and Motion Effects by Affine Whole-Brain Registrations: Evaluation of Three-Dimensional Distortions and Comparison With Slicewise Correction
    Mohammadi, Siawoosh
    Moeller, Harald E.
    Kugel, Harald
    Mueller, Dirk K.
    Deppe, Michael
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (04) : 1047 - 1056