Comparisons of Reproducibility and Mean Values of Diffusion Tensor Imaging-Derived Indices between Unipolar and Bipolar Diffusion Pulse Sequences

被引:6
作者
Miao, Hsiao-Chien [1 ]
Wu, Ming-Ting [2 ]
Kao, E-Fong [1 ]
Chiu, Yu-Hsien [3 ]
Chou, Ming-Chung [1 ,3 ]
机构
[1] Kaohsiung Med Univ, Dept Med Imaging & Radiol Sci, Kaohsiung 80708, Taiwan
[2] Kaohsiung Vet Gen Hosp, Dept Radiol, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ, Dept Healthcare Adm & Med Informat, Dept Healthcare, Kaohsiung, Taiwan
关键词
Unipolar; bipolar; DTI; reproducibility; mean value; PRINCIPAL EIGENVECTOR MEASUREMENTS; EDDY-CURRENT ARTIFACTS; BRAIN WHITE-MATTER; FRACTIONAL ANISOTROPY; ECHO TIME; B-VALUE; TISSUES; IMAGES; 1.5T; MRI;
D O I
10.1111/jon.12231
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Eddy current distortion is an important issue that may influence the quantitative measurements of diffusion tensor imaging (DTI). The corrections of eddy current artifacts could be performed using bipolar diffusion gradients or unipolar gradients with affine registration. Whether the diffusion pulse sequence affects the quantification of DTI indices and the technique that produces more reliable DTI indices in terms of reproducibility both remain unclear. Therefore, the purpose of this study was to compare the reproducibility and mean values of DTI-derived indices between unipolar and bipolar diffusion pulse sequences based on actual human brain data. Five repeated datasets of unipolar and bipolar DTI were acquired from 10 healthy subjects at different echo times (TEs). The reproducibility and mean values of DTI indices were assessed by calculating the coefficient of variation and mean values of the 5 repeated measurements. The results revealed that the reproducibility and mean values of DTI indices were significantly affected by the pulse sequence. Unipolar DTI exhibited significantly higher reproducibility than bipolar DTI even at the same TE, and the mean values of DTI indices were significantly different between them. Therefore, we concluded that the reproducibility and mean values of DTI indices were significantly influenced by diffusion pulse sequences.
引用
收藏
页码:892 / 899
页数:8
相关论文
共 34 条
  • [1] Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients
    Alexander, AL
    Tsuruda, JS
    Parker, DL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) : 1016 - 1021
  • [2] Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
  • [3] 2-O
  • [4] MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. BIOPHYSICAL JOURNAL, 1994, 66 (01) : 259 - 267
  • [5] Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
  • [6] Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity
    Bodammer, N
    Kaufmann, J
    Kanowski, M
    Tempelmann, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 188 - 193
  • [7] Characterization and correction of eddy-current artifacts in unipolar and bipolar diffusion sequences using magnetic field monitoring
    Chan, Rachel W.
    von Deuster, Constantin
    Giese, Daniel
    Stoeck, Christian T.
    Harmer, Jack
    Aitken, Andrew P.
    Atkinson, David
    Kozerke, Sebastian
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2014, 244 : 74 - 84
  • [8] MR DIFFUSION IMAGING OF THE HUMAN BRAIN
    CHIEN, D
    BUXTON, RB
    KWONG, KK
    BRADY, TJ
    ROSEN, BR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) : 514 - 520
  • [9] Effects of b-Value and Echo Time on Magnetic Resonance Diffusion Tensor Imaging-Derived Parameters at 1.5 T: A Voxel-Wise Study
    Chou, Ming-Chung
    Kao, E-Fong
    Mori, Susumu
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2013, 33 (01) : 45 - 50
  • [10] MR COLOR MAPPING OF MYELIN FIBER ORIENTATION
    DOUEK, P
    TURNER, R
    PEKAR, J
    PATRONAS, N
    LEBIHAN, D
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (06) : 923 - 929