Modelling and infrared radiation compensation for non-contact temperature measurement

被引:0
|
作者
Shen, Chih-Hsiung [1 ]
Chang, Tsung-Dai [1 ]
Chen, Shu-Jung [1 ]
机构
[1] Natl Changhua Univ Educ, Dept Mechatron Engn, 2 Shi Da Rd, Changhua, Taiwan
关键词
D O I
10.1088/1757-899X/383/1/012023
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Beyond the conventional non-contact temperature measurement with ambient temperature compensation and our previous work of multi-sensors compensation, two compensation schemes are proposed and compared. An infrared radiation measurement module with several temperature sensors are built and calibrated with ambient compensation to investigate the dynamic temperature distribution under moving of module from one place to another. The new approach we proposed including the infrared radiation exchanges model between the target, sensor and the optical path thorough temperature monitoring and two fast temperature measurement schemes with dynamic compensation. After careful calibrations and verification of several experiment conditions, our models of two dynamic compensation schemes both show an excellent agreement with the measuring data. The experimental data of compensation scheme reach a stable reading value of target temperature down from 40 min to 2 min for the differential scheme compensation and 6 min for multi-sensors scheme compensation with temperature error around 0.2 degrees C.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Assessment of Non-Contact Infrared Thermometer Measurement Sites in Birds
    Anderson, Jessica
    Kaplan-Stein, Sara
    Adolph, Stephen
    Peralta, Jose M.
    JOURNAL OF APPLIED ANIMAL WELFARE SCIENCE, 2020, 23 (02) : 131 - 139
  • [32] NON-CONTACT INFRARED TEMPERATURE MEASUREMENT OF ULTRASONIC LITHOTRIPTERS - A COMPARISON OF COMMONLY USED LITHOTRIPSY DEVICES
    Keil, Christian
    Olbert, Peter
    Hegele, Axel
    Schrader, Andres Jan
    Hofmann, Rainer
    JOURNAL OF UROLOGY, 2010, 183 (04): : E613 - E613
  • [33] Orientation error compensation of turntable for calibration of a non-contact measurement system
    Huo, Ju
    Zhong, Xiao-Qing
    Yang, Ming
    Liu, Jia
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (01): : 100 - 105
  • [34] Non-contact infrared thermometers
    Vernon, Gervase
    BRITISH JOURNAL OF GENERAL PRACTICE, 2014, 64 (629): : 615 - 615
  • [35] Research on the Double-Crystal Temperature Compensation of an Optical Sensor for the Non-contact Measurement of Over Voltage
    Xian, Tianhua
    Zheng, Feng
    Lu, Shicai
    Zhang, Lei
    Yang, Jian
    Liu, Tong
    Han, Rui
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [36] Non-contact temperature measurement and special features of measurement of metal surfaces
    Luger, Thomas
    Elektrowaerme International, 2010, (04): : 289 - 292
  • [37] Non-contact infrared temperature measurements in dry permafrost boreholes
    Junker, Ralf
    Grigoriev, Mikhail N.
    Kaul, Norbert
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2008, 113 (B4)
  • [38] Non-contact measurement of contact wire
    Yi Yaxing
    Ye Xuemei
    Li Zhongke
    Yue Kaiduan
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS, 2009, 7160
  • [39] MEASUREMENT OF PROCESS VARIABLES IN SUGAR INDUSTRY: NON-CONTACT TEMPERATURE MEASUREMENT
    Kadlec, Karel
    LISTY CUKROVARNICKE A REPARSKE, 2016, 132 (9-10): : 303 - 307
  • [40] A non-contact FBG vibration sensor with double differential temperature compensation
    Li, Tianliang
    Tan, Yuegang
    Zhou, Zude
    Zheng, Kai
    OPTICAL REVIEW, 2016, 23 (01) : 26 - 32