Modelling and infrared radiation compensation for non-contact temperature measurement

被引:0
|
作者
Shen, Chih-Hsiung [1 ]
Chang, Tsung-Dai [1 ]
Chen, Shu-Jung [1 ]
机构
[1] Natl Changhua Univ Educ, Dept Mechatron Engn, 2 Shi Da Rd, Changhua, Taiwan
关键词
D O I
10.1088/1757-899X/383/1/012023
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Beyond the conventional non-contact temperature measurement with ambient temperature compensation and our previous work of multi-sensors compensation, two compensation schemes are proposed and compared. An infrared radiation measurement module with several temperature sensors are built and calibrated with ambient compensation to investigate the dynamic temperature distribution under moving of module from one place to another. The new approach we proposed including the infrared radiation exchanges model between the target, sensor and the optical path thorough temperature monitoring and two fast temperature measurement schemes with dynamic compensation. After careful calibrations and verification of several experiment conditions, our models of two dynamic compensation schemes both show an excellent agreement with the measuring data. The experimental data of compensation scheme reach a stable reading value of target temperature down from 40 min to 2 min for the differential scheme compensation and 6 min for multi-sensors scheme compensation with temperature error around 0.2 degrees C.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Influence of sun radiation on results of non-contact temperature measurements in far infrared range
    Madura, H
    Kolodziejczyk, M
    OPTO-ELECTRONICS REVIEW, 2005, 13 (03) : 253 - 257
  • [22] Long wavelength infrared radiation thermometry for non-contact temperature measurements in gas turbines
    Manara, J.
    Zipf, M.
    Stark, T.
    Arduini, M.
    Ebert, H. -P.
    Tutschke, A.
    Hallam, A.
    Hanspal, J.
    Langley, M.
    Hodge, D.
    Hartmann, J.
    INFRARED PHYSICS & TECHNOLOGY, 2017, 80 : 120 - 130
  • [23] Non-contact Local Temperature Measurement inside an Object Using an Infrared Point Detector
    Hisaka, Masaki
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2017, 10251
  • [24] Donor Temperature Screening with a Non-Contact Infrared Thermometer
    Navarro, Marie
    Molfese, Paul M.
    Rioveros, Jowin
    Villasin, Emylee
    Godoy, Jessica
    Ziman, Alyssa
    McGonigle, Andrea M.
    Mei, Zhen Wei
    Ward, Dawn C.
    TRANSFUSION, 2022, 62 : 151A - 151A
  • [25] Non-contact thickness measurement with multilayer radiation structure
    Haroune, Feddal
    Mohamed, Tellache
    Mohamed, El Afendi
    Tao Junwu
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2018, 60 (10) : 2429 - 2437
  • [26] Application of a Multichannel Radiation Thermometer for Increase in Adequacy of Non-contact Temperature Measurement Results
    Chernysheva, Nadezda S.
    Ionov, Anton B.
    2015 16TH INTERNATIONAL CONFERENCE OF YOUNG SPECIALISTS ON MICRO/NANOTECHNOLOGIES AND ELECTRON DEVICES, 2015, : 334 - 336
  • [27] Non-contact temperature measurement systems for industrial processes
    Zimmerhackl, M
    Nagel, F
    Budzier, H
    Hofmann, G
    TECHNISCHES MESSEN, 1999, 66 (03): : 109 - 115
  • [28] Non-contact temperature measurement of semitransparent silicon wafers
    Ikeda, Yoshikazu
    Iuchi, Tohru
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 3412 - +
  • [29] Non-contact measurement of the temperature profile of PET preforms
    Saggin, Bortolino
    Tarabini, Marco
    Scaccabarozzi, Diego
    Cornolti, Luca
    Giberti, Hermes
    Moschioni, Giovanni
    MEASUREMENT, 2019, 133 : 412 - 420
  • [30] New polaradiometric method for non-contact temperature measurement
    Abtahi, A
    Barmatz, M
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM (STAIF-96), PTS 1-3: 1ST CONFERENCE ON COMMERCIAL DEVELOPMENT OF SPACE; 1ST CONFERENCE ON NEXT GENERATION LAUNCH SYSTEMS; 2ND SPACECRAFT THERMAL CONTROL SYMPOSIUM; 13TH SYMPOSIUM ON SPACE NUCLEAR POWER AND PROPULSION - FUTURE SPACE AND EARTH SCIENCE MISSIONS - SPECIAL TOPIC; REMOTE SENSING FOR COMMERCIAL, CIVIL AND SCIENCE APPLICATIONS - SPECIAL TOPIC, 1996, (361): : 303 - 307