Effect of pure and binary fluids on closed loop pulsating heat pipe thermal performance

被引:30
|
作者
Pachghare, Pramod R. [1 ]
Mahalle, Ashish M. [2 ]
机构
[1] Govt Coll Engn, Dept Mech Engn, Amravati 444604, India
[2] Laxinarayan Inst Technol, Dept Gen Engn, Nagpur 444001, Maharashtra, India
来源
CHEMICAL, CIVIL AND MECHANICAL ENGINEERING TRACKS OF 3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE2012) | 2013年 / 51卷
关键词
Pulsating heat pipe; binary mixtures; heat flux; pure natural convection; PART;
D O I
10.1016/j.proeng.2013.01.088
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper presents preliminary experimental results on thermal performance of closed loop pulsating heat pipe (PHP) using copper tube having internal and external diameter with 2.0 mm and 3.6 mm respectively. For all experimentation, filling ratio (FR) was 50 %, ten turns and different heat inputs of 10 to 100W was supplied to PHP. The position of the PHP was vertical bottom heat mode. The equal length of evaporator, adiabatic and condenser section was maintained 50 mm. Working fluids are selected as Methanol, ethanol, acetone, water and different binary mixtures. In order to study, characteristics of the thermal resistance and average evaporator temperatures at different heat input for various working fluids. Experimental study on PHP indicated working fluid is an important factor for the performance of PHPs. The result shows that, the thermal resistance decreases more rapidly with the increase of the heating power from 20 to 60 W, whereas slowly decreases above 60 W. Pure acetone gives best thermal performance in comparisons with the other working fluid. No measurable difference has been recorded between the PHP running with pure and binary mixture working fluids. (C) 2013 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:624 / 629
页数:6
相关论文
共 50 条
  • [22] EFFECT OF WORKING FLUID AND FILLING RATIO ON PERFORMANCE OF A CLOSED LOOP PULSATING HEAT PIPE
    Babu, E. R.
    Reddy, G. V. Gnanendra
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2016, 11 (06) : 872 - 880
  • [23] An experimental investigation on the effect of fin in the performance of closed loop pulsating heat pipe (CLPHP)
    Rahman, M. Lutfor
    Sultan, Rasel A.
    Islam, T.
    Hasan, Noor M.
    Ali, Mohammad
    6TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING, 2015, 105 : 137 - 144
  • [24] Closed-loop pulsating heat pipe
    Tong, BY
    Wong, TN
    Ooi, KT
    APPLIED THERMAL ENGINEERING, 2001, 21 (18) : 1845 - 1862
  • [25] Experimental Investigations on Thermal Performance of a Multi-turn Closed Loop Pulsating Heat Pipe
    Wang, Yu
    Li, Weiyi
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 5854 - 5860
  • [26] Experimental study of thermal performance in a closed loop pulsating heat pipe with alternating superhydrophobic channels
    Betancur, Luis
    Mangini, Daniele
    Mantelli, Marcia
    Marengo, Marco
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 17
  • [27] Experimental investigation on performance of a rotating closed loop pulsating heat pipe
    Aboutalebi, M.
    Moghaddam, A. M. Nikravan
    Mohammadi, N.
    Shafii, M. B.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 45 : 137 - 145
  • [28] Experimental investigation on thermal performance of closed loop pulsating heat pipes with soluble and insoluble binary working fluids and a proposed correlation
    Zamani, R.
    Kalan, K.
    Shafii, M. B.
    HEAT AND MASS TRANSFER, 2019, 55 (02) : 375 - 384
  • [29] Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat Pipe
    Naik, R.
    Varadarajan, V.
    Pundarika, G.
    Narasimha, K. R.
    JOURNAL OF APPLIED FLUID MECHANICS, 2013, 6 (02) : 267 - 275
  • [30] Investigation on the performance of closed-loop pulsating heat pipe with surfactant
    Wang, Jiansheng
    Xie, Jinyuan
    Liu, Xueling
    APPLIED THERMAL ENGINEERING, 2019, 160