The enhanced performance of CFST beams using different strengthening schemes involving unidirectional CFRP sheets: An experimental study

被引:41
作者
Al Zand, Ahmed W. [1 ]
Badaruzzaman, Wan Hamidon W. [1 ]
Mutalib, Azrul A. [1 ]
Hilo, Salam J. [1 ]
机构
[1] Univ Kebangsaan Malaysia, Dept Civil & Struct Engn, Bangi 43600, Selangor, Malaysia
关键词
CFST beam; Flexural stiffness; Partial strengthening scheme; CFRP sheets; STEEL TUBULAR COLUMNS; FLEXURAL BEHAVIOR; STRUCTURAL BEHAVIOR; AXIAL-COMPRESSION; HOLLOW SECTIONS; CONCRETE; TUBES; COMPOSITE; MEMBERS; ADHESION;
D O I
10.1016/j.engstruct.2016.09.044
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled steel tube (CFST) beam, like any conventional structural member, for several reasons need strengthening, such as by making upgrades to carry extra loads or to make repairs owing to degradation attributed to aging, fire, and fatigue. This study experimentally investigates the strengthening behaviour of the circular and rectangular simply supported CFST beams using unidirectional carbon fibre reinforced polymer (CFRP) sheets, in which partial-unilateral (partial), full-unilateral (full), and full-bilateral (combined) strengthening schemes with varied layers and lengths are used. The results show that the moment capacity, energy absorption capacity, and flexural stiffness of the strengthened beam significantly improved with the increase of CFRP layers. For example, the moment capacity of the rectangular beams increased by about 26% and 38% when they were partially strengthened with two and three CFRP layers, respectively. Also, the beams were partially strengthened with two CFRP layers laid along 75% and 100% of their lengths, and that fully strengthened along 100% of its length, all achieved almost the same load improvements (+26% to +28%) in comparison with their control beam, which means that about 50% of the amount of CFRP sheets or even more can be saved and the same improvement can be achieved. The energy absorption capacity of the circular beams improved by about 21.8% when they were partially strengthened with two CFRP sheets, for example. Moreover, the flexural stiffness values of the strengthened beams fairly agreed with those predicted from the existing standards (AISC, EC4, BS5400, and AIJ) after including the effects of CFRP. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:184 / 198
页数:15
相关论文
共 36 条
[1]  
AIJ, 1997, Recommendations for Design and Construction of Concrete Filled Steel Tubular Structures
[2]   Finite element analysis of square CFST beam strengthened by CFRP composite material [J].
Al Zand, Ahmed W. ;
Badaruzzaman, Wan Hamidon W. ;
Mutalib, Azrul A. ;
Qahtan, A. H. .
THIN-WALLED STRUCTURES, 2015, 96 :348-358
[3]  
Al-Zand AW, 2017, J ENG SCI TECHNOL, V12, P1
[4]  
[Anonymous], 2000, ANN BOOK ASTM STAND
[5]  
[Anonymous], 1979, BS5400
[6]  
[Anonymous], 2010, AISC 360-10
[7]  
Arivalagan Kandasamy, 2009, ENG SCI TECHNOLOGY R, V2, P145
[8]  
ASTM, 2009, ASTME8E8M
[9]   Adhesively-bonded joints and repairs in metallic alloys, polymers and composite materials: Adhesives, adhesion theories and surface pretreatment [J].
Baldan, A .
JOURNAL OF MATERIALS SCIENCE, 2004, 39 (01) :1-49
[10]   Hollow and concrete filled steel hollow sections under transverse impact loads [J].
Bambach, M. R. ;
Jama, H. ;
Zhao, X. L. ;
Grzebieta, R. H. .
ENGINEERING STRUCTURES, 2008, 30 (10) :2859-2870