Reliability, agreement, and responsiveness of a 6-minute walk/run test in patients with heart disease

被引:4
|
作者
Berghmans, Danielle D. [1 ]
Lenssen, Antoine F. [1 ]
Bastiaenen, Carolien H. [2 ]
Ilhan, Mustafa [1 ]
Lencer, Nicole H. [1 ]
Roox, George M. [1 ]
机构
[1] Maastricht Univ, Med Ctr, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, NL-6202 AZ Maastricht, Netherlands
关键词
6-minute walk test; 6-minute walk/run test; cardiac rehabilitation; EXERCISE CAPACITY; FAILURE; REPRODUCIBILITY; PERFORMANCE; VALIDITY; CHILDREN;
D O I
10.1177/2047487312437038
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The 6-minute walk test (6MWT) is widely used to assess exercise tolerance in cardiac rehabilitation (CR). However, previous research shows it to be insufficiently responsive, especially for patients with a relatively high maximal exercise tolerance at baseline. We therefore designed a 6-minute walk/run test (6MWRT), which has the same duration as the 6MWT but allows running. The objective of this study was to determine the test-retest reproducibility and responsiveness of this 6MWRT. Design: Responsiveness was investigated in a prospective cohort study among a group of patients entering CR at Maastricht University Medical Center, with a cross-sectional part to assess the test-retest reproducibility. Methods: Test-retest reproducibility (reliability and agreement) was investigated using the intraclass correlation (ICC) and a Bland-Altman plot of two measurements implemented in the first week of rehabilitation. Responsiveness of the 6MWT and the 6MWRT was calculated using the standard response mean (SRM) over a 6-week period. Results: The first reproducibility analysis included 34 patients, the second 22 patients. The ICCs were 0.935 and 0.906, respectively, with limits of agreement of +/- 79 and +/- 61 m. The responsiveness analysis included 27 patients. The SRM values were 0.83 for the 6MWT and 0.71 for the 6MWRT. Conclusions: Although the 6MWRT is a reproducible test in CR, its responsiveness is not superior to that of the 6MWT. We therefore prefer the conventional 6MWT as an evaluative measurement in CR and advise against using the 6MWRT as (evaluative) measurement in CR for this purpose.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 50 条
  • [21] The Long-Term Prognostic Significance of 6-Minute Walk Test Distance in Patients with Chronic Heart Failure
    Ingle, Lee
    Cleland, John G.
    Clark, Andrew L.
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [22] Responsiveness and Minimally Important Difference of the 6-Minute Stepper Test in Patients with Chronic Obstructive Pulmonary Disease
    Pichon, Romain
    Couturaud, Francis
    Mialon, Philippe
    Le Ber-Moy, Catherine
    Peran, Loic
    Lochon, Chantal
    Nowak, Emmanuel
    Beaumont, Marc
    RESPIRATION, 2016, 91 (05) : 367 - 373
  • [23] Different COPD Disease Characteristics are Related to Different Outcomes in the 6-minute Walk Test
    Waatevik, Marie
    Johannessen, Ane
    Hardie, Jon A.
    Bjordal, Jan Magnus
    Aukrust, Pal
    Bakke, Per S.
    Eagan, Tomas M. L.
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2012, 9 (03) : 227 - 234
  • [24] Physiological response to the 6-minute walk test in chronic heart failure patients versus healthy control subjects
    Deboeck, Gael
    Van Muylem, Alain
    Vachiery, Jean Luc
    Naeije, Robert
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2014, 21 (08) : 997 - 1003
  • [25] The 6-minute Run Test: Validation and Reference Equations for Adults
    Leuschner, Malte
    Grauduszus, Martin
    Friesen, David
    Ferrari, Nina
    Klaudius, Marlen
    Joisten, Christine
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2024, 45 (03) : 222 - 230
  • [26] Reproducibility and relationships of the 6-minute walk test and shuttle walk test in children with cerebral palsy
    Silva, Natalia
    Cahalin, Lawrence
    Dal Corso, Simone
    Ross, Arena
    Oliveira, Claudia
    Sampaio, Luciana Malosa
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [27] Lack of Specificity of the 6-Minute Walk Test as an Outcome Measure for Patients with Systemic Sclerosis
    Schoindre, Yoland
    Meune, Christophe
    Dinh-Xuan, Anh Tuan
    Avouac, Jerome
    Kahan, Andre
    Allanore, Yannick
    JOURNAL OF RHEUMATOLOGY, 2009, 36 (07) : 1481 - 1485
  • [28] Measurement Properties and Determinants of the 6-Minute Walk Test in Patients with Lower Limb Lymphedema
    Cakir, Ahmet Burak
    Karadibak, Didem
    Gultekin, Sukriye Cansu
    Acar, Serap
    Keskinoglu, Pembe
    LYMPHATIC RESEARCH AND BIOLOGY, 2025, 23 (01) : 1 - 10
  • [29] Dynamic hyperinflation and dyspnea during the 6-minute walk test in stable chronic obstructive pulmonary disease patients
    Satake, Masahiro
    Shioya, Takanobu
    Uemura, Sachiko
    Takahashi, Hitomi
    Sugawara, Keiyu
    Kasai, Chikage
    Kiyokawa, Noritaka
    Watanabe, Toru
    Sato, Sayaka
    Kawagoshi, Atsuyoshi
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2015, 10 : 153 - 158
  • [30] Predictors of dynamic hyperinflation during the 6-minute walk test in stable chronic obstructive pulmonary disease patients
    Chen, Rui
    Lin, Lin
    Tian, Jing-Wei
    Zeng, Bin
    Zhang, Lei
    Chen, Xin
    Yan, Hai-Yan
    JOURNAL OF THORACIC DISEASE, 2015, 7 (07) : 1142 - U256