Objective assessment of deformable image registration in radiotherapy: A multi-institution study

被引:120
作者
Kashani, Rojano [1 ]
Hub, Martina [2 ]
Balter, James M. [1 ]
Kessler, Marc L. [1 ]
Dong, Lei [3 ]
Zhang, Lifei [3 ]
Xing, Lei [4 ]
Xie, Yaoqin [4 ]
Hawkes, David [5 ]
Schnabel, Julia A. [5 ]
McClelland, Jamie [5 ]
Joshi, Sarang [6 ]
Chen, Quan [7 ]
Lu, Weiguo [7 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] Deutsch Krebsforschungszentrum, Dept Radiat Oncol, D-6900 Heidelberg, Germany
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[4] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[5] UCL, Ctr Med Image Comp, London, England
[6] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT 84112 USA
[7] TomoTherapy Inc, Madison, WI 53717 USA
关键词
computerised tomography; image registration; medical image processing; phantoms; radiation therapy;
D O I
10.1118/1.3013563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area are based on the ability of alignment to reproduce analytically generated deformations applied to sample image data, or use of contours or bifurcations as ground truth for evaluation of alignment accuracy. In this study, a deformable phantom was embedded with 48 small plastic markers, placed in regions varying from high contrast to roughly uniform regional intensity, and small to large regional discontinuities in movement. CT volumes of this phantom were acquired at different deformation states. After manual localization of marker coordinates, images were edited to remove the markers. The resulting image volumes were sent to five collaborating institutions, each of which has developed previously published deformable alignment tools routinely in use. Alignments were done, and applied to the list of reference coordinates at the inhale state. The transformed coordinates were compared to the actual marker locations at exhale. A total of eight alignment techniques were tested from the six institutions. All algorithms performed generally well, as compared to previous publications. Average errors in predicted location ranged from 1.5 to 3.9 mm, depending on technique. No algorithm was uniformly accurate across all regions of the phantom, with maximum errors ranging from 5.1 to 15.4 mm. Larger errors were seen in regions near significant shape changes, as well as areas with uniform contrast but large local motion discontinuity. Although reasonable accuracy was achieved overall, the variation of error in different regions suggests caution in globally accepting the results from deformable alignment.
引用
收藏
页码:5944 / 5953
页数:10
相关论文
共 41 条
  • [1] Accuracy of finite element model-based multi-organ deformable image registration
    Brock, KK
    Sharpe, MB
    Dawson, LA
    Kim, SM
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1647 - 1659
  • [2] CHOU YY, 2004, IEEE INT S BIOMED IM, V1, P716
  • [3] Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines
    Coselmon, MM
    Balter, JM
    McShan, DL
    Kessler, ML
    [J]. MEDICAL PHYSICS, 2004, 31 (11) : 2942 - 2948
  • [4] Automatic online adaptive radiation therapy techniques for targets with significant shape change: a feasibility study
    Court, LE
    Tishler, RB
    Petit, J
    Cormack, R
    Chin, L
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10) : 2493 - 2501
  • [5] An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer
    Court, LE
    Dong, L
    Lee, AK
    Cheung, R
    Bonnen, MD
    O'Daniel, J
    Wang, H
    Mohan, R
    Kuban, D
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (01): : 154 - 163
  • [6] Davis BC, 2005, LECT NOTES COMPUT SC, V3749, P442
  • [7] Formulating adaptive radiation therapy (ART) treatment planning into a closed-loop control framework
    de la Zerda, Adam
    Armbruster, Benjamin
    Xing, Lei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14) : 4137 - 4153
  • [8] Large deformation three-dimensional image registration in image-guided radiation therapy
    Foskey, M
    Davis, B
    Goyal, L
    Chang, S
    Chaney, E
    Strehl, N
    Tomei, S
    Rosenman, J
    Joshi, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24) : 5869 - 5892
  • [9] Intrathoracic tumour motion estimation from CT imaging using the 3D optical flow method
    Guerrero, T
    Zhang, G
    Huang, TC
    Lin, KP
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17) : 4147 - 4161
  • [10] HARTKENS T, 2002, P BILDV MED 2002 MAR, P409