Comparison of the New Perimetric GATE Strategy with Conventional Full-Threshold and SITA Standard Strategies

被引:54
作者
Schiefer, Ulrich [1 ]
Pascual, John P. [4 ]
Edmunds, Beth [5 ]
Feudner, Elisabeth [2 ]
Hoffmann, Esther M. [6 ]
Johnson, Chris A. [7 ]
Lagreze, Wolf A. [8 ]
Pfeiffer, Norbert [6 ]
Sample, Pamela A. [4 ]
Staubach, Flemming [8 ]
Weleber, Richard G.
Vonthein, Reinhard [3 ]
Krapp, Elke [1 ]
Paetzold, Jens [1 ]
机构
[1] Univ Tubingen, Ctr Ophthalmol, Inst Ophthalm Res, D-72076 Tubingen, Germany
[2] Univ Tubingen, Univ Eye Hosp, Ctr Ophthalmol, D-72076 Tubingen, Germany
[3] Univ Tubingen, Dept Med Biometry, D-72076 Tubingen, Germany
[4] Univ Calif San Diego, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[5] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97201 USA
[6] Univ Eye Hosp, Mainz, Germany
[7] Univ Iowa, Dept Ophthalmol & Visual Sci, Iowa City, IA USA
[8] Univ Eye Hosp, Freiberg, Germany
关键词
VISUAL-FIELD EXAMINATION; AUTOMATED PERIMETRY; SUSPECT GLAUCOMA; STATIC PERIMETRY; ALGORITHMS; MANIFEST;
D O I
10.1167/iovs.08-2229
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. A new, fast-threshold strategy, German Adaptive Thresholding Estimation (GATE/GATE-i), is compared to the full-threshold ( FT) staircase and the Swedish Interactive Thresholding Algorithm (SITA) Standard strategies. GATE-i is performed in the initial examination and GATE refers to the results in subsequent examinations. METHODS. Sixty subjects were recruited for participation in the study: 40 with manifest glaucoma, 10 with suspected glaucoma, and 10 with ocular hypertension. The subjects were evaluated by each threshold strategy on two separate sessions within 14 days in a randomized block design. RESULTS. SITA standard, GATE-i, and GATE thresholds were 1.2, 0.6, and 0.0 dB higher than FT. The SITA standard tended to have lower thresholds than those of FT, GATE-i, and GATE for the more positive thresholds, and also in the five seed locations. For FT, GATE-i, GATE, and SITA Standard, the standard deviations of thresholds between sessions were, respectively, 3.9, 4.5, 4.2, and 3.1 dB, test-retest reliabilities (Spearman's rank correlations) were 0.84, 0.76, 0.79, and 0.71, test-retest agreements as measured by the 95% reference interval of differences were -7.69 to 7.69, -8.76 to 9.00, -8.40 to 8.56, and -7.01 to 7.44 dB, and examination durations were 9.0, 5.7, 4.7, and 5.6 minutes. The test duration for SITA Standard increased with increasing glaucomatous loss. CONCLUSIONS. The GATE algorithm achieves thresholds that are similar to those of FT and SITA Standard, with comparable accuracy, test - retest reliability, but with a shorter test duration than FT. (Invest Ophthalmol Vis Sci. 2009;50:488-494) DOI:10.1167/iovs.08-2229
引用
收藏
页码:488 / 494
页数:7
相关论文
共 23 条
  • [1] Anderson D.R., 1999, Automated static perimetry, V2nd
  • [2] Comparison of Swedish interactive threshold algorithm and full threshold algorithm for glaucomatous visual field loss
    Aoki, Y.
    Takahashi, G.
    Kitahara, K.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (02) : 196 - 202
  • [3] Artes PH, 2002, INVEST OPHTH VIS SCI, V43, P2654
  • [4] Aulhorn E, 1977, DOC OPHTHALMOL P SER, P75
  • [5] SITA Fast, a new rapid perimetric threshold test. Description of methods and evaluation in patients with manifest and suspect glaucoma
    Bengtsson, B
    Heijl, A
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (04): : 431 - 437
  • [6] Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma
    Bengtsson, B
    Heijl, A
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (03): : 268 - 272
  • [7] Bengtsson B, 1997, ACTA OPHTHALMOL SCAN, V75, P368
  • [8] Evaluation of a new threshold visual field strategy, SITA, in normal subjects
    Bengtsson, B
    Heijl, A
    Olsson, J
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (02): : 165 - 169
  • [9] European Chemicals Bureau, 2003, TECHN GUID DOC RIS 2, P1
  • [10] Age-dependent normative values for differential luminance sensitivity in automated static perimetry using the Octopus 101
    Hermann, Agnes
    Paetzold, Jens
    Vonthein, Reinhard
    Krapp, Elke
    Rauscher, Stephan
    Schiefer, Ulrich
    [J]. ACTA OPHTHALMOLOGICA, 2008, 86 (04) : 446 - 455