Estimation of myocardial blood flow for longitudinal studies with N-13-labeled ammonia and positron emission tomography

被引:91
作者
DeGrado, TR
Hanson, MW
Turkington, TG
Delong, DM
Brezinski, DA
Vallee, JP
Hedlund, LW
Zhang, J
Cobb, F
Sullivan, MJ
Coleman, RE
机构
[1] DUKE UNIV, MED CTR, DEPT RADIOL, DIV CARDIOL, DURHAM, NC 27710 USA
[2] DUKE UNIV, MED CTR, DEPT MED, DURHAM, NC 27710 USA
关键词
myocardial blood flow; PET; N-13; ammonia; compartmental modeling;
D O I
10.1016/S1071-3581(96)90059-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background, Although several modeling strategies have been developed and validated for quantification of myocardial blood flow (MBF) from N-13-labeled ammonia positron emission tomographic data, a comparison of noise characteristics of the various techniques in serial studies is lacking. Methods and Results, Dynamic N-13-labeled ammonia positron emission tomographic imaging was performed at baseline and after pharmacologic stress in (1) single studies of four dogs with concomitant measurement of microsphere blood flow and (2) initial and follow-up studies of eight normal volunteers, Data were obtained from short-axis images for the blood pool and myocardial regions corresponding to the three arterial vascular territories, Indexes of MBF were obtained by four distinct techniques: (1) University of California, Los Angeles, two-compartment model, (2) Michigan two-compartment model, and (3) a one-compartment model with variable blood volume term, Coronary flow reserve (CFR) was measured as the ratio of stress/rest MBF. The estimated standard deviation of the measurement error for the relative change between studies of rest and stress MBF and CFR was determined for each technique, Estimates of MBF from all techniques showed good correlation with microsphere blood flow (r = 0.95 to 0.96) in canine myocardium. In human studies, similar mean estimates of MBF were found with all techniques, Techniques 1 and 3 showed the smallest interstudy variability in MBE and CER, The estimated standard deviations for these techniques were approximately 20%, 30%, and 27% for rest MBF, stress MBF, and CFR, respectively, Conclusion. Noninvasive quantification of MBF and CFR from dynamic N-13-labeled ammonia positron emission tomography is most reproducible with technique 1 or 3, The ability to account for differences in myocardial partial volume gives preference to technique 3, However, substantial interstudy variability in regional MBF remains, suggesting the importance of procedural factors or real temporal fluctuations in MBF.
引用
收藏
页码:494 / 507
页数:14
相关论文
共 32 条
  • [1] BELLINA CR, 1990, J NUCL MED, V31, P1335
  • [2] NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY
    BERGMANN, SR
    HERRERO, P
    MARKHAM, J
    WEINHEIMER, CJ
    WALSH, MN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) : 639 - 652
  • [3] BERRY JJ, 1991, J NUCL MED, V32, P1518
  • [4] COMPARISON OF MAXIMAL MYOCARDIAL BLOOD-FLOW DURING ADENOSINE INFUSION WITH THAT OF INTRAVENOUS DIPYRIDAMOLE IN NORMAL MEN
    CHAN, SY
    BRUNKEN, RC
    CZERNIN, J
    PORENTA, G
    KUHLE, W
    KRIVOKAPICH, J
    PHELPS, ME
    SCHELBERT, HR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (04) : 979 - 985
  • [5] CHOI Y, 1993, J NUCL MED, V34, P488
  • [6] CZERNIN J, 1994, J NUCL MED, V35, pP24
  • [7] DEGRADO TR, 1994, J NUCL MED, V35, P1398
  • [8] RELATION AMONG STENOSIS SEVERITY, MYOCARDIAL BLOOD-FLOW, AND FLOW RESERVE IN PATIENTS WITH CORONARY-ARTERY DISEASE
    DICARLI, M
    CZERNIN, J
    HOH, CK
    GERBAUDO, VH
    BRUNKEN, RC
    HUANG, SC
    PHELPS, ME
    SCHELBERT, HR
    [J]. CIRCULATION, 1995, 91 (07) : 1944 - 1951
  • [9] NONINVASIVE ASSESSMENT OF CORONARY STENOSES BY MYOCARDIAL PERFUSION IMAGING DURING PHARMACOLOGIC CORONARY VASODILATATION .1. PHYSIOLOGIC BASIS AND EXPERIMENTAL VALIDATION
    GOULD, KL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (02) : 267 - 278
  • [10] HUTCHINS GD, 1992, J NUCL MED, V33, P1243