Non-Scatter Contributions to the Dark-Field Signal in Differential Phase Contrast Imaging

被引:2
作者
Koehler, Thomas [1 ]
Martens, Gerhard [1 ]
van Stevendaal, Udo [1 ]
Roessl, Ewald [1 ]
机构
[1] Philips Technol GmbH, Innovat Technol, Res Labs, Hamburg, Germany
来源
INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS | 2012年 / 1466卷
关键词
x-ray imaging; scatter imaging; Talbot interferometer;
D O I
10.1063/1.4742293
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this work, we investigate sources to the dark-field signal in a grating-based differential phase contrast image setup other than scattering. Specifically, the effect of aliasing, detector crosstalk, non-constant phase gradients, and the partial volume effect are evaluated. All these effects are able to create a dark-field signal.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 9 条
[1]   Quantitative x-ray dark-field computed tomography [J].
Bech, M. ;
Bunk, O. ;
Donath, T. ;
Feidenhans'l, R. ;
David, C. ;
Pfeiffer, F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18) :5529-5539
[2]   Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping [J].
Bevins, Nicholas ;
Zambelli, Joseph ;
Li, Ke ;
Qi, Zhihua ;
Chen, Guang-Hong .
MEDICAL PHYSICS, 2012, 39 (01) :424-428
[3]   Noise properties of grating-based x-ray phase contrast computed tomography [J].
Koehler, Thomas ;
Engel, Klaus Juergen ;
Roessl, Ewald .
MEDICAL PHYSICS, 2011, 38 :S106-S116
[4]   Demonstration of X-Ray Talbot interferometry [J].
Momose, A ;
Kawamoto, S ;
Koyama, I ;
Hamaishi, Y ;
Takai, K ;
Suzuki, Y .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (7B) :L866-L868
[5]   Hard-X-ray dark-field imaging using a grating interferometer [J].
Pfeiffer, F. ;
Bech, M. ;
Bunk, O. ;
Kraft, P. ;
Eikenberry, E. F. ;
Broennimann, Ch. ;
Gruenzweig, C. ;
David, C. .
NATURE MATERIALS, 2008, 7 (02) :134-137
[6]   Hard X-ray phase tomography with low-brilliance sources [J].
Pfeiffer, F. ;
Kottler, C. ;
Bunk, O. ;
David, C. .
PHYSICAL REVIEW LETTERS, 2007, 98 (10)
[7]   Quantitative grating-based x-ray dark-field computed tomography [J].
Wang, Zhen-Tian ;
Kang, Ke-Jun ;
Huang, Zhi-Feng ;
Chen, Zhi-Qiang .
APPLIED PHYSICS LETTERS, 2009, 95 (09)
[8]   X-ray phase imaging with a grating interferometer [J].
Weitkamp, T ;
Diaz, A ;
David, C ;
Pfeiffer, F ;
Stampanoni, M ;
Cloetens, P ;
Ziegler, E .
OPTICS EXPRESS, 2005, 13 (16) :6296-6304
[9]   On the origin of visibility contrast in x-ray Talbot interferometry [J].
Yashiro, W. ;
Terui, Y. ;
Kawabata, K. ;
Momose, A. .
OPTICS EXPRESS, 2010, 18 (16) :16890-16901