Fabrication of electrochemical theophylline sensor based on manganese oxide nanoparticles/ionic liquid/chitosan nanocomposite modified glassy carbon electrode

被引:77
|
作者
MansouriMajd, Samira [1 ]
Teymourian, Hazhir [1 ]
Salimi, Abdollah [1 ,2 ]
Hallaj, Rahman [1 ]
机构
[1] Univ Kurdistan, Dept Chem, Sanandaj 6617715175, Iran
[2] Univ Kurdistan, Res Ctr Nanotechnol, Sanandaj 6617715175, Iran
关键词
Electrochemical sensor; Chitosan; Ionic liquid; Manganese oxide nanoparticles; Theophylline; IONIC LIQUID; MNO2; NANOPARTICLES; NANOTUBES; OXIDATION; CHITOSAN; DIOXIDE; FILM; ELECTROCATALYSIS; NANOSTRUCTURES; REACTIVITY;
D O I
10.1016/j.electacta.2013.07.029
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, the preparation of a glassy carbon (GC) electrode modified with chitosan/NH2-ionic liquid/manganese oxide nanoparticles (Chit/NH2-IL/MnOx) was described for electrocatalytic detection of theophylline (TP). First, chitosan hydrogel (Chit) was electrodeposited on the GC electrode surface at a constant potential (-1.5V) in acidic solution. Then, the previously synthesized amine-terminated 1-(3-Aminopropyl)-3-methylimidazolium bromide ionic liquid (NH2-IL) was covalently attached to the modified electrode via glutaraldehyde (GA) as linking agent. Finally, manganese oxide (MnOx) nanoparticles were electrodeposited onto the Chit/NH2-IL film by potential cycling between -1.0 and 1.7 V in Mn(CH3COO)(2)center dot 4H(2)O neutral aqueous solution. Electrochemical behavior of the modified electrode was evaluated by cyclic voltammetry (CV) technique. The charge transfer coefficient (a) and electron transfer rate constant (k(s)) for MnOOH/MnO2 redox couple were calculated to be 0.35 and 1.62 s(-1), respectively. The resulting system brings new capabilities for electrochemical sensing through combining the advantages of IL and MnOx nanoparticles. The differential pulse voltammetric (DPV) results indicated the high ability of GC/Chit/NH2-IL/MnOx modified electrode to catalyze the oxidation of TP. DPV determination of TP in acetate buffer solution (pH 5) gave linear responses over the concentration range up to 120 mu M with the detection limit of 50 nM and sensitivity of 804 nA mu M-1. Furthermore, the applicability of the sensor for TP analysis in pharmaceutical samples has been successfully demonstrated. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:707 / 716
页数:10
相关论文
共 50 条
  • [31] Simple non-enzymatic electrochemical sensor for hydrogen peroxide based on nafion/platinum nanoparticles/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Zhang, Cong
    Jiang, Haohai
    Ma, Rui
    Zhang, Yanyan
    Chen, Qiang
    IONICS, 2017, 23 (05) : 1309 - 1317
  • [32] Determination of 4-aminophenylarsonic acid using a glassy carbon electrode modified with an ionic liquid and carbon nanohorns
    Dai, Hong
    Gong, Lingshan
    Lu, Shuangyan
    Zhang, Qingrong
    Li, Yilin
    Zhang, Shupei
    Xu, Guifang
    Li, Xiuhua
    Lin, Yanyu
    Chen, Guonan
    MICROCHIMICA ACTA, 2015, 182 (7-8) : 1247 - 1254
  • [33] Simultaneous Voltammetric Determination of Theophylline and Guaifenesin Using a Multiwalled Carbon Nanotube-Ionic Liquid Modified Glassy Carbon Electrode
    Gholivand, Mohammad Bagher
    Khodadadian, Mehdi
    ELECTROANALYSIS, 2014, 26 (09) : 1975 - 1983
  • [34] Diagnostic kit based on halloysite nanoclay-ionic liquid nanocomposite modified electrode for electrochemical determination of cancer biomarker
    Yildiz, Esma
    Yurdacan, Beste
    Erac, Yasemin
    Erdem, Arzum
    TALANTA, 2023, 252
  • [35] Immunoassay for serum amyloid A using a glassy carbon electrode modified with carboxy-polypyrrole, multiwalled carbon nanotubes, ionic liquid and chitosan
    Chunyong Xia
    Yuan Li
    Guolin Yuan
    Yanlei Guo
    Chao Yu
    Microchimica Acta, 2015, 182 : 1395 - 1402
  • [36] Immunoassay for serum amyloid A using a glassy carbon electrode modified with carboxy-polypyrrole, multiwalled carbon nanotubes, ionic liquid and chitosan
    Xia, Chunyong
    Li, Yuan
    Yuan, Guolin
    Guo, Yanlei
    Yu, Chao
    MICROCHIMICA ACTA, 2015, 182 (7-8) : 1395 - 1402
  • [37] Electrochemical sensor based on glassy carbon electrode modified by polymelamine formaldehyde/graphene oxide nanocomposite for ultrasensitive detection of oxycodone
    Khosropour, Hossein
    Rezaei, Behzad
    Alinajafi, Hossein A.
    Ensafi, Ali A.
    MICROCHIMICA ACTA, 2021, 188 (01)
  • [38] Electrochemical sensor based on glassy carbon electrode modified by polymelamine formaldehyde/graphene oxide nanocomposite for ultrasensitive detection of oxycodone
    Hossein Khosropour
    Behzad Rezaei
    Hossein A. Alinajafi
    Ali A. Ensafi
    Microchimica Acta, 2021, 188
  • [39] An amperometric sensor based on ionic liquid and carbon nanotube modified composite electrode for the determination of nitrite in milk
    Zhou, Ling
    Wang, Jian-Ping
    Gai, Ling
    Li, Du-Juan
    Li, Yan-Bin
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 : 65 - 70
  • [40] Electrochemical tyrosine sensor based on a glassy carbon electrode modified with a nanohybrid made from graphene oxide and multiwalled carbon nanotubes
    Li, Junhua
    Kuang, Daizhi
    Feng, Yonglan
    Zhang, Fuxing
    Xu, Zhifeng
    Liu, Mengqin
    Wang, Deping
    MICROCHIMICA ACTA, 2013, 180 (1-2) : 49 - 58