A Field Study of Aging in Paper-Oil Insulation Systems

被引:64
|
作者
Lelekakis, Nick [1 ]
Guo, Wenyu [1 ]
Martin, Daniel [1 ]
Wijaya, Jaury [1 ]
Susa, Dejan [2 ]
机构
[1] Monash Univ, Ctr Power Transformer Monitoring Diagnost & Life, Clayton, Vic 3800, Australia
[2] SINTEF, Energy Res Dept, N-7034 Trondheim, Norway
关键词
power transformer; paper aging; degree of polymerization; furan analysis;
D O I
10.1109/MEI.2012.6130527
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper used to insulate the windings of power transformers is mostly made from wood pulp, a cellulosic material. Over decades the paper is slowly attacked by water, oxygen, oil acids, and high temperatures and eventually degrades to the point where it is no longer an effective insulator. The transformer is then likely to fail. Power utilities need to know when a transformer is nearing the end of its useful life in order to plan its replacement. However, a problem with monitoring the condition of the paper within a transformer is that it may be difficult to obtain a sample to test. Furthermore, a particular sample may not accurately reflect the overall paper condition. A power transformer operating in Australia failed in 2010. Thus we had the opportunity to study the paper condition at various points within the transformer and evaluate the validity of the current understanding of paper aging. In this article we discuss the mechanisms of cellulose degradation, and the associated equations, and apply them to the paper insulation in the failed transformer. © 2012 IEEE.
引用
收藏
页码:12 / 19
页数:8
相关论文
共 50 条
  • [1] Application of Aging Studies to the Evaluation of Paper-Oil Insulation of Power Capacitors.
    Buck, Jozef
    Przeglad Elektrotechniczny, 1972, 48 (10): : 452 - 455
  • [3] PAPER-OIL INSULATION - NEW DEFINITION OF DAMAGE
    ASENJO, E
    EIDELSTEIN, G
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1978, 13 (03): : 179 - 183
  • [4] Study of Modification of Electric Field Distribution in Paper-Oil Insulation of Transformer in the Presence of Copper Sulphide
    Flora, S. Daisy
    Kumari, M. Kanya
    Rajan, J. Sundara
    PROCEEDINGS OF THE 2014 IEEE 18TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL 2014), 2014,
  • [5] Study of anomalous breakdown of paper-oil insulation under unconventional voltages
    Viswanatha, C.
    Rajan, J.Sundara
    Dwarakanath, K.
    Nema, R.S.
    IEEE International Conference on Conduction and Breakdown in Dielectric Liquids, ICDL, 1999, : 219 - 222
  • [6] Influence of sludge on electric processes in paper-oil insulation
    Zenker, Marek
    Mrozik, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (11B): : 334 - 336
  • [7] Dielectric spectroscopy of paper-oil insulation with depositions on the cellulose
    Zenker, Marek
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11B): : 82 - 85
  • [8] Electric field regulation in paper-oil insulation with capacitor facings. Part 1
    Kolechitskij, E.S.
    Plis, A.I.
    Shul'gin, V.N.
    Elektrichestvo, 1995, (09): : 36 - 41
  • [9] Statistical Analysis and Fuzzy Logic Identification of Partial Discharge in Paper-Oil Insulation Systems
    Chen, X.
    Cavallini, A.
    Montanari, G. C.
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 505 - 508
  • [10] Mechanisms of the Appearance of Partial Discharges in Paper-Oil Insulation.
    Galand, Jean
    Morel, Jean Francois
    Golinski, Jacek
    Labus-Nawrat, Kasylda
    Przeglad Elektrotechniczny, 1975, 51 (01): : 14 - 18