Graphene versus Multi-Walled Carbon Nanotubes for Electrochemical Glucose Biosensing

被引:67
作者
Zheng, Dan [1 ,2 ]
Vashist, Sandeep Kumar [1 ,3 ]
Dykas, Michal Marcin [1 ,4 ]
Saha, Surajit [1 ,5 ]
Al-Rubeaan, Khalid [6 ]
Lam, Edmond [7 ]
Luong, John H. T. [7 ]
Sheu, Fwu-Shan [1 ,3 ]
机构
[1] Natl Univ Singapore, NUSNNI NanoCore, T Lab Level 11, 5A Engn Dr 1, Singapore 117580, Singapore
[2] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[3] Natl Univ Singapore, Dept Elect & Comp Engn, Singapore 117576, Singapore
[4] Natl Univ Singapore, NUS Grad Sch Integrat Sci & Engn, Singapore 117456, Singapore
[5] Natl Univ Singapore, Dept Phys, Singapore 117572, Singapore
[6] King Saud Univ, Univ Diabet Ctr, Riyadh 11415, Saudi Arabia
[7] Natl Res Council Canada, Montreal, PQ H4P 2R2, Canada
关键词
graphene; multi-walled carbon nanotubes; electrochemical glucose sensor; glucose oxidase; DIRECT ELECTRON-TRANSFER; GOLD NANOPARTICLES; OXIDASE; COMPOSITE; LAYER; FILM; NANOCOMPOSITES; OXIDATION;
D O I
10.3390/ma6031011
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A simple procedure was developed for the fabrication of electrochemical glucose biosensors using glucose oxidase (GOx), with graphene or multi-walled carbon nanotubes (MWCNTs). Graphene and MWCNTs were dispersed in 0.25% 3-aminopropyltriethoxysilane (APTES) and drop cast on 1% KOH-pre-treated glassy carbon electrodes (GCEs). The EDC (1-ethyl-(3-dimethylaminopropyl) carbodiimide)-activated GOx was then bound covalently on the graphene- or MWCNT-modified GCE. Both the graphene- and MWCNT-based biosensors detected the entire pathophysiological range of blood glucose in humans, 1.4-27.9 mM. However, the direct electron transfer (DET) between GOx and the modified GCE's surface was only observed for the MWCNT-based biosensor. The MWCNT-based glucose biosensor also provided over a four-fold higher current signal than its graphene counterpart. Several interfering substances, including drug metabolites, provoked negligible interference at pathological levels for both the MWCNT- and graphene-based biosensors. However, the former was more prone to interfering substances and drug metabolites at extremely pathological concentrations than its graphene counterpart.
引用
收藏
页码:1011 / 1027
页数:17
相关论文
共 62 条
[31]   Materials and Transducers Toward Selective Wireless Gas Sensing [J].
Potyrailo, Radislav A. ;
Surman, Cheryl ;
Nagraj, Nandini ;
Burns, Andrew .
CHEMICAL REVIEWS, 2011, 111 (11) :7315-7354
[32]   Amperometric sensor based on ferrocene-modified multiwalled carbon nanotube nanocomposites as electron mediator for the determination of glucose [J].
Qiu, Jian-Ding ;
Zhou, Wen-Mei ;
Guo, Jin ;
Wang, Rui ;
Liang, Ru-Ping .
ANALYTICAL BIOCHEMISTRY, 2009, 385 (02) :264-269
[33]   Evidence for charge transfer in doped carbon nanotube bundles from Raman scattering [J].
Rao, AM ;
Eklund, PC ;
Bandow, S ;
Thess, A ;
Smalley, RE .
NATURE, 1997, 388 (6639) :257-259
[34]   Detection of individual gas molecules adsorbed on graphene [J].
Schedin, F. ;
Geim, A. K. ;
Morozov, S. V. ;
Hill, E. W. ;
Blake, P. ;
Katsnelson, M. I. ;
Novoselov, K. S. .
NATURE MATERIALS, 2007, 6 (09) :652-655
[35]   The Heterogeneity of Multiwalled and Single-Walled Carbon Nanotubes: Iron Oxide Impurities Can Catalyze the Electrochemical Oxidation of Glucose [J].
Siegert, Laurent ;
Kampouris, Dimitrios K. ;
Kruusma, Jaanus ;
Sammelselg, Vaeino ;
Banks, Craig E. .
ELECTROANALYSIS, 2009, 21 (01) :48-51
[36]   Graphene-based composite materials [J].
Stankovich, Sasha ;
Dikin, Dmitriy A. ;
Dommett, Geoffrey H. B. ;
Kohlhaas, Kevin M. ;
Zimney, Eric J. ;
Stach, Eric A. ;
Piner, Richard D. ;
Nguyen, SonBinh T. ;
Ruoff, Rodney S. .
NATURE, 2006, 442 (7100) :282-286
[37]   Signal Transducers and Enzyme Cofactors are Susceptible to Oxidation by Nanographite Impurities in Carbon Nanotube Materials [J].
Stuart, Emma J. E. ;
Pumera, Martin .
CHEMISTRY-A EUROPEAN JOURNAL, 2011, 17 (20) :5544-5548
[38]   Effect of antibody immobilization strategies on the analytical performance of a surface plasmon resonance-based immunoassay [J].
Vashist, Sandeep Kumar ;
Dixit, Chandra Kumar ;
MacCraith, Brian D. ;
O'Kennedy, Richard .
ANALYST, 2011, 136 (21) :4431-4436
[39]   Delivery of drugs and biomolecules using carbon nanotubes [J].
Vashist, Sandeep Kumar ;
Zheng, Dan ;
Pastorin, Giorgia ;
Al-Rubeaan, Khalid ;
Luong, John H. T. ;
Sheu, Fwu-Shan .
CARBON, 2011, 49 (13) :4077-4097
[40]   Advances in carbon nanotube based electrochemical sensors for bioanalytical applications [J].
Vashist, Sandeep Kumar ;
Zheng, Dan ;
Al-Rubeaan, Khalid ;
Luong, John H. T. ;
Sheu, Fwu-Shan .
BIOTECHNOLOGY ADVANCES, 2011, 29 (02) :169-188